Resonance frequency measurements of implant stability in vivo - A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla

被引:348
|
作者
Meredith, N
Book, K
Friberg, B
Jemt, T
Sennerby, L
机构
[1] Dept. of Oral and Dental Science, University of Bristol Dental School, Bristol BS1 2LY, Lower Maudlin Street
[2] Dept. of Biomaterials/Handicap Res., Institute for Surgical Sciences, Göteborg University, Gothenburg
[3] Branemark Clinic, Public Dental Health, University of Göteborg, Gothenburg
关键词
dental; implant; osseointegration; resonance frequency; stability;
D O I
10.1034/j.1600-0501.1997.080309.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this investigation was to evaluate the use of resonance frequency measurements in the clinical measurement of implant stability. Resonance frequency measurements are undertaken by measuring the response of a small transducer attached to an implant fixture or abutment. Two groups of patients were selected for study. Group A comprised 9 patients who had a total of 56 implants placed. Resonance frequency measurements were made at fixture installation and repeated 8 months later at abutment connection. The resonance frequency of the implant/transducer system increased for 50 out of the 56 implants from a mean value of 7473 Hz +/- 127 Hz (P<0.05) to a mean of 7915 Hz +/- 112 Hz (P<0.05). Two implants had failed to integrate and the resonance frequency of these had fallen. Group B comprised 9 patients who had been provided with fixed prostheses and had a total of 52 implants placed. They were examined 5 years after fixture placement and the prostheses removed. All implants were judged clinically to be osseointegrated. The level of the marginal bone around each implant was calculated by measuring the number of exposed threads on intraoral periapical radiographs and added to the length of each abutment to give a value termed the effective implant length (EIL). Measurements indicated a correlation (R = -0.78, P<0.01) between EIL and resonance frequency. The results support the hypothesis that the resonance frequency of an implant/ transducer system is related to the height of the implant not surrounded by bone and the stability of the implant/tissue interface as determined by the absence of clinical mobility.
引用
收藏
页码:226 / 233
页数:8
相关论文
共 50 条
  • [31] Initial Stability of Two Dental Implant Systems: Influence of Buccolingual Width and Probe Orientation on Resonance Frequency Measurements
    Tozum, Tolga F.
    Turkyilmaz, Ilser
    Bal, Bilge Turhan
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2010, 12 (03) : 194 - 201
  • [32] Tomographic Planning of Dental Implants Using a Smartphone: Linear Measurements and Implant Selection- A Cross-Sectional Study
    Schallenberger, Veronica
    Maracci, Lucas Machado
    Ortigara, Gabriela Barbieri
    Serpa, Geraldo Fagundes
    Liedke, Gabriela Salatino
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (05) : e175 - e181
  • [33] The Predictive Value of Resonance Frequency Analysis Measurements in the Surgical Placement and Loading of Endosseous Implants
    Baltayan, Serge
    Pi-Anfruns, Joan
    Aghaloo, Tara
    Moy, Peter K.
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 74 (06) : 1145 - 1152
  • [34] ASSESSMENT OF PRIMARY AND SECONDARY IMPLANT STABILITY BY RESONANCE FREQUENCY ANALYSIS IN ANTERIOR AND POSTERIOR SEGMENTS OF MAXILLARY EDENTULOUS RIDGES
    Baftijari, Denis
    Benedetti, Alberto
    Kirkov, Antonio
    Iliev, Aleksandar
    Stamatoski, Aleksandar
    Baftijari, Florent
    Deliverska, Elitsa G.
    Gjorgievska, Elizabeta
    JOURNAL OF IMAB, 2018, 24 (02): : 2058 - 2064
  • [35] A comparison between cutting torque and resonance frequency measurements of maxillary implants - A 20-month clinical study
    Friberg, B
    Sennerby, L
    Meredith, N
    Lekholm, U
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 28 (04) : 297 - 303
  • [36] Normative measurements of orbital structures on magnetic resonance images; a cross-sectional study with mini review of the literature
    Volkan Kızılgöz
    Sonay Aydın
    Hüseyin Aydemir
    Mecit Kantarcı
    Surgical and Radiologic Anatomy, 2024, 46 : 595 - 604
  • [37] Normative measurements of orbital structures on magnetic resonance images; a cross-sectional study with mini review of the literature
    Kizilgoz, Volkan
    Aydin, Sonay
    Aydemir, Huseyin
    Kantarci, Mecit
    SURGICAL AND RADIOLOGIC ANATOMY, 2024, 46 (05) : 595 - 604
  • [38] Assessment of Miniscrew Implant Stability by Resonance Frequency Analysis: A Study in Human Cadavers
    Suzuki, Eduardo Yugo
    Suzuki, Boonsiva
    Aramrattana, Atchara
    Harnsiriwattanakit, Kanchana
    Kowanich, Narumanas
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2010, 68 (11) : 2682 - 2689
  • [39] Reconstructions and cross-sectional area measurements from magnetic resonance microscopic images of the cochlea
    Wilson, JL
    Henson, MM
    Gewalt, SL
    Keating, AW
    Henson, OW
    AMERICAN JOURNAL OF OTOLOGY, 1996, 17 (02): : 347 - 353
  • [40] An Ex Vivo Model in Human Femoral Heads for Histopathological Study and Resonance Frequency Analysis of Dental Implant Primary Stability
    Hernandez-Cortes, Pedro
    Monje, Alberto
    Galindo-Moreno, Pablo
    Catena, Andres
    Ortega-Oller, Inmaculada
    Salas-Perez, Jose
    Mesa, Francisco
    Gomez-Sanchez, Rafael
    Aguilar, Mariano
    Aguilar, David
    O'Valle, Francisco
    BIOMED RESEARCH INTERNATIONAL, 2014, 2014