Resonance frequency measurements of implant stability in vivo - A cross-sectional and longitudinal study of resonance frequency measurements on implants in the edentulous and partially dentate maxilla

被引:348
|
作者
Meredith, N
Book, K
Friberg, B
Jemt, T
Sennerby, L
机构
[1] Dept. of Oral and Dental Science, University of Bristol Dental School, Bristol BS1 2LY, Lower Maudlin Street
[2] Dept. of Biomaterials/Handicap Res., Institute for Surgical Sciences, Göteborg University, Gothenburg
[3] Branemark Clinic, Public Dental Health, University of Göteborg, Gothenburg
关键词
dental; implant; osseointegration; resonance frequency; stability;
D O I
10.1034/j.1600-0501.1997.080309.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this investigation was to evaluate the use of resonance frequency measurements in the clinical measurement of implant stability. Resonance frequency measurements are undertaken by measuring the response of a small transducer attached to an implant fixture or abutment. Two groups of patients were selected for study. Group A comprised 9 patients who had a total of 56 implants placed. Resonance frequency measurements were made at fixture installation and repeated 8 months later at abutment connection. The resonance frequency of the implant/transducer system increased for 50 out of the 56 implants from a mean value of 7473 Hz +/- 127 Hz (P<0.05) to a mean of 7915 Hz +/- 112 Hz (P<0.05). Two implants had failed to integrate and the resonance frequency of these had fallen. Group B comprised 9 patients who had been provided with fixed prostheses and had a total of 52 implants placed. They were examined 5 years after fixture placement and the prostheses removed. All implants were judged clinically to be osseointegrated. The level of the marginal bone around each implant was calculated by measuring the number of exposed threads on intraoral periapical radiographs and added to the length of each abutment to give a value termed the effective implant length (EIL). Measurements indicated a correlation (R = -0.78, P<0.01) between EIL and resonance frequency. The results support the hypothesis that the resonance frequency of an implant/ transducer system is related to the height of the implant not surrounded by bone and the stability of the implant/tissue interface as determined by the absence of clinical mobility.
引用
收藏
页码:226 / 233
页数:8
相关论文
共 50 条
  • [21] Relationship between implant stability measurements obtained by insertion torque and resonance frequency analysis: A systematic review
    Lages, Frederico Santos
    Douglas-de Oliveira, Dhelfeson Willya
    Costa, Fernando Oliveira
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2018, 20 (01) : 26 - 33
  • [22] Parameters of Implant Stability Measurements Based on Resonance Frequency and Damping Capacity: A Comparative Finite Element Analysis
    Winter, Werner
    Moehrle, Stefan
    Holst, Stefan
    Karl, Matthias
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2010, 25 (03) : 532 - 539
  • [23] A comparison between cutting torque and resonance frequency measurements of mandibular implants.
    Pessoa, T
    Nary, HF
    Francischone, CE
    Falcao, R
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 131 - 131
  • [25] Magnetic resonance imaging measurements of bone density and cross-sectional geometry
    Hong, J
    Hipp, JA
    Mulkern, RV
    Jaramillo, D
    Snyder, BD
    CALCIFIED TISSUE INTERNATIONAL, 2000, 66 (01) : 74 - 78
  • [26] Magnetic Resonance Imaging Measurements of Bone Density and Cross-Sectional Geometry
    J. Hong
    J. A. Hipp
    R. V. Mulkern
    D. Jaramillo
    B. D. Snyder
    Calcified Tissue International, 2000, 66 : 74 - 78
  • [27] Comparison of Implant Stability by Means of Resonance Frequency Analysis for Flapless and Conventionally Inserted Implants
    Katsoulis, Joannis
    Avrampou, Marianna
    Spycher, Christian
    Stipic, Marko
    Enkling, Norbert
    Mericske-Stern, Regina
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (06) : 915 - 923
  • [28] Resonance frequency analysis as a predictor of early implant failure in the partially edentulous posterior maxilla following immediate nonfunctional loading or delayed loading with single unit restorations
    Kim, Steven J.
    Ribeiro, Alexandre L. V. L.
    Atlas, Alan M.
    Saleh, Najeed
    Royal, Jamie
    Radvar, Mehrdad
    Korostoff, Jonathan
    CLINICAL ORAL IMPLANTS RESEARCH, 2015, 26 (02) : 183 - 190
  • [29] Comparison of implant stability measurements between a resonance frequency analysis device and a modified damping capacity analysis device: an in vitro study
    Lee, Jungwon
    Pyo, Se-Wook
    Cho, Hyun-Jae
    An, Jung-Sub
    Lee, Jae-Hyun
    Koo, Ki-Tae
    Lee, Yong-Moo
    JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2020, 50 (01): : 56 - 66
  • [30] Theoretical study of the accuracy limits of optical resonance frequency measurements
    Labzowsky, L.
    Schedrin, G.
    Solovyev, D.
    Plunien, G.
    PHYSICAL REVIEW LETTERS, 2007, 98 (20)