Reliability and Reproducibility of Manual and Automated Volumetric Measurements of Periapical Lesions

被引:3
|
作者
Aoki, Eduardo Massaharu [1 ]
Abdala-Junior, Reinaldo [1 ]
de Oliveira, Jefferson Xavier [1 ]
Arita, Emiko Saito [1 ]
Gonzalez Cortes, Arthur Rodriguez [2 ,3 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Sao Paulo, Brazil
[2] Massachusetts Gen Hosp, Dept Radiol, Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[3] Harvard Univ, Sch Med, Boston, MA USA
关键词
Cone-beam computed tomography; periapical lesions; region growing; segmentation; volumetric measurements; BEAM COMPUTED-TOMOGRAPHY; APICAL PERIODONTITIS; BONE DEFECTS; ACCURACY; CT; RADIOGRAPHY; SOFTWARE; IMPLANTS; TEETH; SCANS;
D O I
10.1016/j.joen.2015.06.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The present study aimed to test the reliability and reproducibility of 2 methods: manual and automated segmentation (using a threshold-based region growing algorithm) for measuring the volume of periapical lesions. Methods: A total of 43 cone-beam computed tomographic scans (14 men and 29 women, mean age of 54.6 +/- 8.5 years) were analyzed by 3 observers. Intraobserver reproducibility and inter-observer reliability were assessed using the intraclass correlation coefficient. Parametric correlation between manual and automated volumetric measurements was performed. In addition, the Student t test was also used to compare the mean time required for manual and automated volumetric measurements. Results: Automated segmentation showed slightly higher intraclass correlation coefficient values for all observers. A strong significant correlation was found between manual and automated volumetric measurements performed by the 3 observers. A significant difference in the mean procedure time was also found between both methods (P = .001). Conclusions: Within the limitations of this study, the present results suggest that automated segmentation with a region growing algorithm is faster and slightly more reliable to calculate the volume of periapical lesions.
引用
收藏
页码:1555 / 1559
页数:5
相关论文
共 50 条
  • [31] Reliability of Automated Breast Density Measurements
    Alonzo-Proulx, Olivier
    Mawdsley, Gordon E.
    Patrie, James T.
    Yaffe, Martin J.
    Harvey, Jennifer A.
    RADIOLOGY, 2015, 275 (02) : 366 - 376
  • [32] Reproducibility and reliability assays of the gene expression-measurements
    Darbani, Behrooz
    Stewart, Charles Neal, Jr.
    JOURNAL OF BIOLOGICAL RESEARCH-THESSALONIKI, 2014, 21
  • [33] Intraobserver reproducibility and interobserver reliability of cervical spine measurements
    Wellborn, CC
    Sturm, PF
    Hatch, RS
    Bomze, SR
    Jablonski, K
    JOURNAL OF PEDIATRIC ORTHOPAEDICS, 2000, 20 (01) : 66 - 70
  • [34] Reproducibility and Reliability of Pleural Fluid Cytokine Measurements.
    Bielsa, S.
    Davies, H. E.
    Taylor, A. E.
    Lee, Y. C. Gary
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2009, 179
  • [35] The reliability of different methods of manual volumetric segmentation of pharyngeal and sinonasal subregions
    Neelapu, Bala Chakravarthy
    Kharbanda, Om Prakash
    Sardana, Harish Kumar
    Gupta, Abhishek
    Vasamsetti, Srikanth
    Balachandran, Rajiv
    Rana, Shailendra Singh
    Sardana, Viren
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2017, 124 (06): : 577 - 587
  • [36] Automated hyperemia analysis software: reliability and reproducibility in healthy subjects
    Yoneda, Tsuyoshi
    Sumi, Tamaki
    Takahashi, Ayako
    Hoshikawa, Yasuhiro
    Kobayashi, Masahiko
    Fukushima, Atsuki
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2012, 56 (01) : 1 - 7
  • [37] Automated hyperemia analysis software: reliability and reproducibility in healthy subjects
    Tsuyoshi Yoneda
    Tamaki Sumi
    Ayako Takahashi
    Yasuhiro Hoshikawa
    Masahiko Kobayashi
    Atsuki Fukushima
    Japanese Journal of Ophthalmology, 2012, 56 : 1 - 7
  • [38] Reproducibility of volumetric macular measurements in diabetic patients with the Heidelberg Retina Tomograph
    H.J. Zambarakji
    S.A. Vernon
    A.F. Spencer
    W.M.K. Amoaku
    Documenta Ophthalmologica, 1999, 97 : 349 - 360
  • [39] Reproducibility of volumetric macular measurements in diabetic patients with the Heidelberg Retina Tomograph
    Zambarakji, HJ
    Vernon, SA
    Spencer, AF
    Amoaku, WMK
    DOCUMENTA OPHTHALMOLOGICA, 1999, 97 (3-4) : 349 - 360
  • [40] Rebuttal to Hasan and Pedraza in comments and controversies: "Improving the reliability of manual and automated methods for hippocampal and amygdala volume measurements"
    Morey, Rajendra A.
    Petty, Christopher M.
    Xu, Yuan
    Hayes, Jasmeet Pannu
    Wagner, H. Ryan, II
    Lewis, Darrell V.
    LaBar, Kevin S.
    Styner, Martin
    McCarthy, Gregory
    NEUROIMAGE, 2009, 48 (03) : 499 - 500