Reliability and Reproducibility of Manual and Automated Volumetric Measurements of Periapical Lesions

被引:3
|
作者
Aoki, Eduardo Massaharu [1 ]
Abdala-Junior, Reinaldo [1 ]
de Oliveira, Jefferson Xavier [1 ]
Arita, Emiko Saito [1 ]
Gonzalez Cortes, Arthur Rodriguez [2 ,3 ]
机构
[1] Univ Sao Paulo, Sch Dent, Dept Stomatol, Sao Paulo, Brazil
[2] Massachusetts Gen Hosp, Dept Radiol, Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[3] Harvard Univ, Sch Med, Boston, MA USA
关键词
Cone-beam computed tomography; periapical lesions; region growing; segmentation; volumetric measurements; BEAM COMPUTED-TOMOGRAPHY; APICAL PERIODONTITIS; BONE DEFECTS; ACCURACY; CT; RADIOGRAPHY; SOFTWARE; IMPLANTS; TEETH; SCANS;
D O I
10.1016/j.joen.2015.06.015
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Introduction: The present study aimed to test the reliability and reproducibility of 2 methods: manual and automated segmentation (using a threshold-based region growing algorithm) for measuring the volume of periapical lesions. Methods: A total of 43 cone-beam computed tomographic scans (14 men and 29 women, mean age of 54.6 +/- 8.5 years) were analyzed by 3 observers. Intraobserver reproducibility and inter-observer reliability were assessed using the intraclass correlation coefficient. Parametric correlation between manual and automated volumetric measurements was performed. In addition, the Student t test was also used to compare the mean time required for manual and automated volumetric measurements. Results: Automated segmentation showed slightly higher intraclass correlation coefficient values for all observers. A strong significant correlation was found between manual and automated volumetric measurements performed by the 3 observers. A significant difference in the mean procedure time was also found between both methods (P = .001). Conclusions: Within the limitations of this study, the present results suggest that automated segmentation with a region growing algorithm is faster and slightly more reliable to calculate the volume of periapical lesions.
引用
收藏
页码:1555 / 1559
页数:5
相关论文
共 50 条
  • [21] Reliability and reproducibility issues in DNA microarray measurements
    Draghici, S
    Khatri, P
    Eklund, AC
    Szallasi, Z
    TRENDS IN GENETICS, 2006, 22 (02) : 101 - 109
  • [22] Reproducibility and reliability of pleural fluid cytokine measurements
    Bielsa, S.
    Davies, H. E.
    Davies, R. J. O.
    Taylor, A.
    Lee, Y. C. G.
    EUROPEAN RESPIRATORY JOURNAL, 2009, 34 (04) : 1001 - 1003
  • [23] Reproducibility and Agreeability of Automated Retinal Pigment Epithelial Detachment Volumetric Measurements via Spectral Domain Optical Coherence Tomography
    Ho, Joseph
    Adhi, Mehreen
    Cole, Emily
    Liu, Jonathan
    Fujimoto, James
    Duker, Jay
    Waheed, Nadia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [24] Reproducibility of CT-based opportunistic vertebral volumetric bone mineral density measurements from an automated segmentation framework
    Bodden, Jannis
    Prucker, Philipp
    Sekuboyina, Anjany
    El Husseini, Malek
    Grau, Katharina
    Ruehling, Sebastian
    Burian, Egon
    Zimmer, Claus
    Baum, Thomas
    Kirschke, Jan S.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2024, 8 (01)
  • [25] Reproducibility of volumetric measurements of normal maculae with the Heidelberg retina tomograph
    Zambarakji, HJ
    Evans, JE
    Amoaku, WMK
    Vernon, SA
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1998, 82 (08) : 884 - 891
  • [26] Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented
    Huisman, Jennifer
    Egede, Rasmus
    Rdzanek, Adam
    Boese, Dirk
    Erbel, Raimund
    Kochman, Janusz
    Jensen, Lisette Okkels
    van der Palen, Job
    Hartmann, Marc
    Mintz, Gary S.
    von Birgelen, Clemens
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08): : 1867 - 1878
  • [27] Multicenter assessment of the reproducibility of volumetric radiofrequency-based intravascular ultrasound measurements in coronary lesions that were consecutively stented
    Jennifer Huisman
    Rasmus Egede
    Adam Rdzanek
    Dirk Böse
    Raimund Erbel
    Janusz Kochman
    Lisette Okkels Jensen
    Job van der Palen
    Marc Hartmann
    Gary S. Mintz
    Clemens von Birgelen
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1867 - 1878
  • [28] ACCURACY AND REPRODUCIBILITY IN VOLUMETRIC-ANALYSIS OF MULTIPLE-SCLEROSIS LESIONS
    JACKSON, EF
    NARAYANA, PA
    WOLINSKY, JS
    DOYLE, TJ
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1993, 17 (02) : 200 - 205
  • [29] Asynchronous interpretation of manual and automated audiometry: Agreement and reliability
    Brennan-Jones, Christopher G.
    Eikelboom, Robert H.
    Bennett, Rebecca J.
    Tao, Karina F. M.
    Swanepoel, De Wet
    JOURNAL OF TELEMEDICINE AND TELECARE, 2018, 24 (01) : 37 - 43
  • [30] Comparison Between Manual and Semiautomated Volumetric Measurements of Pituitary Adenomas
    Al Hinai, Qasim
    Mok, Kelvin
    Zeitouni, Anthony
    Gagnon, Bruno
    Ajlan, Abdul Razag
    Rivera, Juan
    Tewfik, Marc
    Sirhan, Denis
    SKULL BASE-AN INTERDISCIPLINARY APPROACH, 2011, 21 (06): : 365 - 371