Implementation and validation of an artificial neural network for predicting the performance of a liquid desiccant dehumidifier

被引:35
|
作者
Mohammad, Abdulrahman Th. [1 ,2 ]
Bin Mat, Sohif [1 ]
Sulaiman, M. Y. [1 ]
Sopian, K. [1 ]
Al-Abidi, Abduljalil A. [1 ]
机构
[1] Univ Kebangsaan Malaysia, Solar Energy Res Inst, Bangi 43600, Selangor, Malaysia
[2] Fdn Tech Educ, Baqubah Tech Inst, Dept Mech Engn, Baghdad, Iraq
关键词
ANN; Dehumidifier; Condensation rate; Effectiveness; AQUEOUS LITHIUM-CHLORIDE; MASS-TRANSFER; AIR DEHUMIDIFICATION; HEAT; SYSTEM; REGENERATOR;
D O I
10.1016/j.enconman.2012.12.005
中图分类号
O414.1 [热力学];
学科分类号
摘要
In the current paper, an artificial neural network (ANN) model for predicting the performance of a liquid desiccant dehumidifier in terms of the water condensation rate and dehumidifier effectiveness is proposed. Six air and desiccant inlet parameters were used as inputs for the ANN. To determine the performance of the ANN technique for predicting the performance of the dehumidifier, actual experimental test data were obtained from a previous study, that tested a packed column dehumidifier with a total height of 0.6 m and a specific packing material surface area of 77 m(2)/m(3) , using triethylene glycol as the desiccant. In the experiment, 54 data samples were used in a series of runs. MATLAB code was designed to study feed forward back propagation with traingdm, learngdm, MSE, and tansig as the training, learning, performance, and transfer functions, respectively. Up to 70% of the experimental data was used to train the model; the remaining 30% was used to test the output. The results show that the 6-3-3-1 network structure was the best model for predicting water condensation rate, whereas the 6-6-6-1 network structure was the best model for predicting dehumidifier effectiveness. The maximum percentage difference between the ANN and experimental value for water condensation rate and dehumidifier effectiveness were 8.13% and 9.0485%, respectively. The model for the water condensation rate and dehumidifier effectiveness could be further improved by modifying the number of hidden layers. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:240 / 250
页数:11
相关论文
共 50 条
  • [31] Analysis and optimization on performance of parallel two stage solar liquid desiccant dehumidifier
    Dai, Y. J.
    Xiong, Z. Q.
    Mei, L.
    Wang, R. Z.
    PROCEEDINGS OF ISES SOLAR WORLD CONGRESS 2007: SOLAR ENERGY AND HUMAN SETTLEMENT, VOLS I-V, 2007, : 514 - 518
  • [32] Liquid desiccant dehumidifier: Development of a new performance predication model based on CFD
    Luo, Yimo
    Yang, Hongxing
    Lu, Lin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2014, 69 : 408 - 416
  • [33] Study on performance of dehumidifier and regenerator of liquid desiccant cooling air conditioning system
    Yin, YG
    Zhang, XS
    Li, YL
    Wu, W
    Chen, ZQ
    Guan, ZS
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 1274 - 1278
  • [34] Investigation on Performance of Internally Cooled Liquid Desiccant Dehumidifier Based on ANN Model
    Luo, Yimo
    Chang, Yayin
    Li, Nianping
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2024, 51 (09): : 198 - 205
  • [35] Performance prediction of solid desiccant rotary system using artificial neural network
    Mishra, V. K.
    Singh, R. P.
    Das, R. K.
    1ST INTERNATIONAL CONFERENCE ON CONTEMPORARY RESEARCH IN MECHANICAL ENGINEERING WITH FOCUS ON MATERIALS AND MANUFACTURING (ICCRME-2018), 2018, 404
  • [36] Predicting roadheader performance by using artificial neural network
    Armin Salsani
    Jahanbakhsh Daneshian
    Shahram Shariati
    Abdolreza Yazdani-Chamzini
    Mehdi Taheri
    Neural Computing and Applications, 2014, 24 : 1823 - 1831
  • [37] Predicting roadheader performance by using artificial neural network
    Salsani, Armin
    Daneshian, Jahanbakhsh
    Shariati, Shahram
    Yazdani-Chamzini, Abdolreza
    Taheri, Mehdi
    NEURAL COMPUTING & APPLICATIONS, 2014, 24 (7-8): : 1823 - 1831
  • [38] Model validation and case study on internally cooled/heated dehumidifier/regenerator of liquid desiccant systems
    Yin, Yonggao
    Zhang, Xiaosong
    Peng, Donggen
    Li, Xiuwei
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2009, 48 (08) : 1664 - 1671
  • [39] Analytical Modeling and Performance Study of a Cross Flow Air Dehumidifier Using Liquid Desiccant
    Bassuoni, M. M.
    MATERIALS RESEARCH AND APPLICATIONS, PTS 1-3, 2014, 875-877 : 1205 - 1213
  • [40] Numerical study on dehumidification performance of a cross-flow liquid desiccant air dehumidifier
    Lu, Jun
    Wang, Meilin
    Li, Yongcai
    Yang, Lulu
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3630 - 3637