Abutment screw loosening in single-implant restorations: A systematic review

被引:0
|
作者
Theoharidou, Anna [1 ]
Petridis, Haralampos P. [1 ]
Tzannas, Konstantinos [2 ]
Garefis, Pavlos [1 ]
机构
[1] Aristotle Univ Thessaloniki, Sch Dent, Dept Fixed Prosthesis & Implant Prosthodont, Thessaloniki 54124, Greece
[2] DCS Co, Thessaloniki, Greece
关键词
implant complications; implant geometry; meta-analysis; screw loosening; single implants;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to systematically review clinical studies on the incidence of abutment screw loosening in single-implant restorations with different implant-abutment connection geometries. Materials and Methods: The literature search was conducted using several electronic databases. Specific terms were used for the database search, which spanned the years 1990 to 2006. The search was augmented by using the option of "related articles" as well as hand searching of references and relevant journals. Relevant studies were selected according to predetermined inclusion and exclusion criteria. Agreement between reviewers was determined by using Cohen's kappa coefficients. Three-year complication-free rates (survival proportions) were calculated with the aid of a survival function, assuming constant failure rates. Summary estimates per group for complication-free rate after 3 years (M-estimator) were calculated using Tukey's biweight estimator. Results: The initial database search yielded 1,526 relevant titles. After the subsequent filtering process, 27 studies were finally selected. Interexaminer agreement ranged from good to perfect. The external-connection group comprised 12 studies following 586 single-implant restorations for a mean follow-up time that ranged from 3 to 5 years. The estimated percent of complication-free single-implant restorations after 3 years was 97.3% (95% Cl: 95.6-98.3). The internal connection group comprised 15 studies following 1,113 single-implant restorations for a mean follow-up time that ranged from 3 to 10 years. The estimated percentage of complication-free single-implant restorations after 3 years was 97.6% (95% Cl: 96.5-98.3). Conclusion: The results show that abutment screw loosening is a rare event in single-implant restorations regardless of the geometry of implant-abutment connection, provided that proper antirotational features and torque are employed.
引用
收藏
页码:681 / 690
页数:10
相关论文
共 50 条
  • [41] Different Methods to Salvage the Fractured Abutment Screws and Potential Reasons of Abutment Screw Loosening: A Narrative Review
    Gir, Prajakta
    Joshi, Snehal
    Vishnupriya, V.
    Marathe, Ashlesha
    Bagul, Abhishek
    Nazirkar, Girish
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2024, 16 (SUPPL 5) : S4198 - S4200
  • [42] Antimicrobial profile of a dental implant abutment coating to prevent adhesion and migration of bacteria and screw loosening
    Rodrigues, M. A.
    Cortez, A. R.
    Cortez, J.
    Gobbo, P.
    Lepicka, M.
    Barros-Silva, S.
    Freitas, P. P.
    Lopes, M. A.
    Mendes, J.
    DENTAL MATERIALS, 2021, 37 (10) : E493 - E501
  • [43] Continuous tooth eruption adjacent to single-implant restorations in the anterior maxilla: aetiology, mechanism and outcomes - A review of the literature
    Mijiritsky, Eitan
    Badran, Maram
    Kleinman, Shlomi
    Manor, Yifat
    Peleg, Oren
    INTERNATIONAL DENTAL JOURNAL, 2020, 70 (03) : 155 - 160
  • [44] Cemented CeraOne® and Porcelain Fused to TiAdapt™ Abutment Single-Implant Crown Restorations: A 10-Year Comparative Follow-Up Study
    Jemt, Torsten
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2009, 11 (04) : 303 - 310
  • [45] Single-Implant Treatment
    Block, Michael S.
    ORAL AND MAXILLOFACIAL SURGERY CLINICS OF NORTH AMERICA, 2019, 31 (02) : 251 - +
  • [46] Implant abutment screw fracture and techniques of retrieval: a literature review based on a novel abutment screw fracture classification
    Chowdhary, R.
    Sonnahalli, N. K.
    Gala, J. N.
    JOURNAL OF OSSEOINTEGRATION, 2023, 15 (01) : 32 - 39
  • [47] Clinical Recommendations for Implant Abutment Selection for Single-Implant Reconstructions: Customized vs Standardized Ceramic and Metallic Solutions
    Zarauz, Cristina
    Pitta, Joao
    Pradies, Guillermo
    Sailer, Irena
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2020, 40 (01) : 31 - 37
  • [48] Influence of CAD/CAM Manufacturing Technique and Implant Abutment Angulation on Loosening of Individual Screw-Retained Implant Crowns
    Rico-Coderch, Aitana
    Felix, Luis F.
    Sola-Ruiz, Maria Fernanda
    Medina, Michell
    Agustin-Panadero, Ruben
    Ortega, Rocio
    Cascos, Rocio
    Gomez-Polo, Miguel
    METALS, 2024, 14 (07)
  • [49] Screw Joint Stability in Conventional and Abutment-Free Implant-Supported Fixed Restorations
    Scherg, Stefan
    Karl, Matthias
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2016, 29 (02) : 142 - 146
  • [50] The Effect of Abutment Screw Length on Screw Loosening in Dental Implants with External Abutment Connections After Thermocycling
    Yeo, In-Sung
    Lee, Joo-Hee
    Kang, Tae-Joo
    Kim, Seong-Kyun
    Heo, Seong-Joo
    Koak, Jai-Young
    Park, Ji-Man
    Lee, Su-Young
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2014, 29 (01) : 59 - 62