Abutment screw loosening in single-implant restorations: A systematic review

被引:0
|
作者
Theoharidou, Anna [1 ]
Petridis, Haralampos P. [1 ]
Tzannas, Konstantinos [2 ]
Garefis, Pavlos [1 ]
机构
[1] Aristotle Univ Thessaloniki, Sch Dent, Dept Fixed Prosthesis & Implant Prosthodont, Thessaloniki 54124, Greece
[2] DCS Co, Thessaloniki, Greece
关键词
implant complications; implant geometry; meta-analysis; screw loosening; single implants;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to systematically review clinical studies on the incidence of abutment screw loosening in single-implant restorations with different implant-abutment connection geometries. Materials and Methods: The literature search was conducted using several electronic databases. Specific terms were used for the database search, which spanned the years 1990 to 2006. The search was augmented by using the option of "related articles" as well as hand searching of references and relevant journals. Relevant studies were selected according to predetermined inclusion and exclusion criteria. Agreement between reviewers was determined by using Cohen's kappa coefficients. Three-year complication-free rates (survival proportions) were calculated with the aid of a survival function, assuming constant failure rates. Summary estimates per group for complication-free rate after 3 years (M-estimator) were calculated using Tukey's biweight estimator. Results: The initial database search yielded 1,526 relevant titles. After the subsequent filtering process, 27 studies were finally selected. Interexaminer agreement ranged from good to perfect. The external-connection group comprised 12 studies following 586 single-implant restorations for a mean follow-up time that ranged from 3 to 5 years. The estimated percent of complication-free single-implant restorations after 3 years was 97.3% (95% Cl: 95.6-98.3). The internal connection group comprised 15 studies following 1,113 single-implant restorations for a mean follow-up time that ranged from 3 to 10 years. The estimated percentage of complication-free single-implant restorations after 3 years was 97.6% (95% Cl: 96.5-98.3). Conclusion: The results show that abutment screw loosening is a rare event in single-implant restorations regardless of the geometry of implant-abutment connection, provided that proper antirotational features and torque are employed.
引用
收藏
页码:681 / 690
页数:10
相关论文
共 50 条
  • [31] Preventing loosening of implant abutment screws
    Cavazos, E
    Bell, FA
    JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (05): : 566 - 569
  • [32] Comparison of the Effect of Four Different Abutment Screw Torques on Screw Loosening in Single Implant-Supported Prosthesis after the Application of Mechanical Loading
    Ebadian, Behnaz
    Fathi, Amirhossein
    Khodadad, Saba
    INTERNATIONAL JOURNAL OF DENTISTRY, 2021, 2021
  • [33] Screw loosening and changes in removal torque relative to abutment screw length in a dental implant with external abutment connection after oblique cyclic loading
    Lee, Joo-Hee
    Cha, Hyun-Suk
    JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (06): : 415 - 421
  • [34] Comparison of Screw Loosening and Fracture Resistance in Different Hybrid Abutment Crown Restorations After Thermomechanical Aging
    Karaoglu, Oyku
    Nemli, Secil Karakoca
    Bal, Bilge Turhan
    Gungor, Merve Bankoglu
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (04) : e113 - e120
  • [35] Abutment screw loosening of endosseous dental implant body/abutment joint by cyclic torsional loading test at the initial stage
    Katsuta, Yasuhiro
    Watanabe, Fumihiko
    DENTAL MATERIALS JOURNAL, 2015, 34 (06) : 896 - 902
  • [36] Bonded provisional restorations for esthetic soft tissue support in single-implant treatment
    Poggio, CE
    Salvato, A
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (06): : 688 - 691
  • [37] AN ALTERNATIVE METHOD FOR REGISTERING THE ABUTMENT SCREW POSITION OF CEMENT-RETAINED IMPLANT RESTORATIONS
    Figueras-Alvarez, Oscar
    Cano-Batalla, Jordi
    JOURNAL OF PROSTHETIC DENTISTRY, 2014, 112 (05): : 1304 - 1305
  • [38] In Vitro Evaluation of Manual Torque Values Applied to Implant-Abutment Complex by Different Clinicians and Abutment Screw Loosening
    Kose, Onur Dincer
    Karatasli, Burcin
    Demircan, Sabit
    Kose, Taha Emre
    Cene, Erhan
    Aya, Serhan Aydjn
    Erdem, Mehmet Ali
    Cankaya, Abdulkadir Burak
    BIOMED RESEARCH INTERNATIONAL, 2017, 2017
  • [39] Prevalence of Interproximal Open Contacts Between Single-Implant Restorations and Adjacent Teeth
    Varthis, Spyridon
    Randi, Anthony
    Tarnow, Dennis P.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2016, 31 (05) : 1089 - 1092
  • [40] An abutment screw loosening study of a Diamond Like Carbon-coated CP titanium implant
    Kim, SK
    Lee, JB
    Koak, JY
    Heo, SJ
    Lee, KR
    Cho, LR
    Lee, SS
    JOURNAL OF ORAL REHABILITATION, 2005, 32 (05) : 346 - 350