In vitro dislocation tendency, stabilizing effect, and subsidence tendency of different lumbar interbody fusion cages

被引:0
|
作者
Kettler, A [1 ]
Dietl, R [1 ]
Krammer, M [1 ]
Lumenta, CB [1 ]
Claes, L [1 ]
Wilke, HJ [1 ]
机构
[1] Inst Unfallchirurg Forsch & Biomech, D-89081 Ulm, Germany
来源
ORTHOPADE | 2002年 / 31卷 / 05期
关键词
lumbar spine; interbody fusion cage; dislocation; flexibility; biomechanics;
D O I
10.1007/s00132-001-0290-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
For biomechanical purposes, interbody fusion cages should not dislocate, should provide high stability,and should have a low subsidence risk. Zientek (Marquardt Medzintechnik), Stryker (Stryker Implants),and Ray lumbar interbody fusion cages (Surgical Dynamics) were tested in this study. They were implanted by pairs from a posterior approach without further stabilization. In a first step, each cage design was implanted into four human L3-4 segments and extracted posteriorly under an axial preload of 200 N. In a second step, standard flexibility tests were carried out with 24 human L2-3 and L4-5 specimens in an intact condition, directly after cage implantation, and after cyclic axial compression loading (200-1000 N, 40,000 cycles, 5 Hz). In a third step, a destructive axial compression test was carried out. Maximum pullout force was highest with Ray cages (median 945 N),followed by Zientek (605 N) and Stryker cages (130 N). With all three cage designs, primary stability was higher in lateral bending and flexion than in extension and axial rotation. Implantation of Ray cages caused a decreased range of motion in all three loading directions ranging between 49% and 99%. Zientek cages only stabilized in lateral bending, flexion, and extension (45-78%) and Stryker cages in none of the three loading directions. Cyclic loading caused an increased range of motion in all cases up to 190%. Axial compression force at failure was 8413 N with Ray cages, 8359 N with Stryker cages, and 5486 N with Zientek cages. The cage design seems to influence the dislocation tendency. In this regard,threaded cages or cages with anchorage systems seem to provide more security. The stabilizing effect seems to be mainly influenced by factors such as the degree of distraction or destruction of the facet joints rather than by the cage design.
引用
收藏
页码:481 / +
页数:7
相关论文
共 50 条
  • [11] Evolution of Design of Interbody Cages for Anterior Lumbar Interbody Fusion
    Phan, Kevin
    Mobbs, Ralph J.
    ORTHOPAEDIC SURGERY, 2016, 8 (03) : 270 - 277
  • [12] Interbody metal implants ("cages") for lumbar fusion
    von Salis-Soglio, GF
    Scholz, R
    Seller, K
    ORTHOPADE, 2005, 34 (10): : 1033 - 1039
  • [13] Stabilisierende Wirkung und Sinterungstendenz dreier unterschiedlicher Cages und Knochenzement zur Fusion von HalswirbelsäulensegmentenStabilizing effect and subsidence tendency of three different cages and bone cement for the fusion of cervical spine segments
    H.-J. Wilke
    A. Kettler
    L. Claes
    Der Orthopäde, 2002, 31 (5): : 472 - 480
  • [14] Subsidence after anterior lumbar interbody fusion using paired stand-alone rectangular cages
    Choi, JY
    Sung, KH
    EUROPEAN SPINE JOURNAL, 2006, 15 (01) : 16 - 22
  • [15] Anterior Lumbar Interbody Fusion Integrated Screw Cages: Intrinsic Load Generation, Subsidence, and Torsional Stability
    Assem, Yusuf
    Pelletier, Matthew H.
    Mobbs, Ralph J.
    Phan, Kevin
    Walsh, William R.
    ORTHOPAEDIC SURGERY, 2017, 9 (02) : 191 - 197
  • [16] Subsidence after anterior lumbar interbody fusion using paired stand-alone rectangular cages
    Jae Young Choi
    Kyeong Hoon Sung
    European Spine Journal, 2006, 15 : 16 - 22
  • [17] Comparison of two interbody fusion cages for posterior lumbar interbody fusion in a cadaveric model
    Wang, Shih-Tien
    Goel, Vijay K.
    Fu, Chong-Yau
    Kubo, Shinichiro
    Choi, Woosung
    Liu, Chien-Lin
    Chen, Tain-Hsiung
    INTERNATIONAL ORTHOPAEDICS, 2006, 30 (04) : 299 - 304
  • [18] Comparison of two interbody fusion cages for posterior lumbar interbody fusion in a cadaveric model
    Shih-Tien Wang
    Vijay K. Goel
    Chong-Yau Fu
    Shinichiro Kubo
    Woosung Choi
    Chien-Lin Liu
    Tain-Hsiung Chen
    International Orthopaedics, 2006, 30 : 299 - 304
  • [19] Pullout test with three lumbar interbody fusion cages
    Dietl, RHJ
    Krammer, M
    Kettler, A
    Wilke, HJ
    Claes, L
    Lumenta, CB
    SPINE, 2002, 27 (10) : 1029 - 1035
  • [20] Expandable Cages for Lumbar Interbody Fusion: A Narrative Review
    Lee, Soo-Bin
    Yoon, Jonghun
    Park, Sung-Jun
    Chae, Dong-Sik
    JOURNAL OF CLINICAL MEDICINE, 2024, 13 (10)