Comparison of Invasive Blood Pressure Measurements from the Caudal Ventral Artery and the Femoral Artery in Male Adult SD and Wistar Rats

被引:19
|
作者
Wang, Ying [1 ]
Cong, Yushuang [1 ]
Li, Jun [1 ]
Li, Xueting [1 ]
Li, Bing [2 ]
Qi, Sihua [1 ]
机构
[1] Harbin Med Univ, Affiliated Hosp 4, Dept Anesthesiol, Harbin, Peoples R China
[2] Harbin Med Univ, Affiliated Hosp 2, Dept Nephrol, Harbin, Peoples R China
来源
PLOS ONE | 2013年 / 8卷 / 04期
基金
中国国家自然科学基金;
关键词
TAIL-ARTERY; MODEL; CUFF; AGREEMENT;
D O I
10.1371/journal.pone.0060625
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and Purpose: Studies have suggested that the caudal ventral artery is a potential site for continuous arterial blood pressure monitoring in rats. However, the agreement of mean arterial pressure values between the femoral artery and the caudal ventral artery has not been investigated. This study was performed to identify whether the caudal ventral artery could be safely used for continuous blood pressure monitoring as an alternative site to the femoral artery. Methods: Rats were randomized into four groups: Sprague Dawley rats under normothermia; Wistar rats under normothermia; Sprague Dawley rats under hypothermia; Wistar rats under hypothermia. Each rat underwent simultaneous monitoring of blood pressure using femoral artery and caudal ventral artery catheterization during a stable hemodynamic state and three periods of acute severe hemodynamic changes. The effects of rat strain, rectal temperature, experimental time course and hemodynamic factors on pressure gradients, the concordance of mean arterial pressure values between the femoral artery and the caudal ventral artery, and the rates of distal ischemia after surgery were determined. Results: There was a significant difference in the rate of distal ischemia between femoral and caudal ventral arteries after catheterization (25% vs 5%, P<0.05). The overall mean gradient and the mean gradient under a steady hemodynamic state were 4.9+/-3.7 mm Hg and 5.5+/-2.5 mm Hg, respectively. The limits of agreement (bias+/-1.96 SD) were (22.5 mm Hg, 12.3 mm Hg) and (-0.5 mm Hg, 10.5 mm Hg), respectively. Although the concordance decreased during the first 30 sec of each period of severe hemodynamic changes, the degree of agreement was acceptable regardless of the effects of rat strain and rectal temperature. Conclusions: Based on the degree of agreement and the safety of catheterization, the caudal ventral artery may be a preferred site for continuous arterial blood pressure monitoring without acute severe hemodynamic changes.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] Nicorandil improves endothelial function of femoral artery without lowering blood pressure in Dahl salt-sensitive rats
    Serizawa, Kenichi
    Yogo, Kenji
    Tashiro, Yoshihito
    Endo, Koichi
    JOURNAL OF PHARMACOLOGICAL SCIENCES, 2013, 121 : 77P - 77P
  • [32] A comparison of radial artery blood pressure determination between the Vasotrac device and invasive arterial blood pressure monitoring in adolescents undergoing scoliosis surgery
    McCann, ME
    Hill, D
    Thomas, KC
    Zurakowski, D
    Laussen, PC
    ANESTHESIA AND ANALGESIA, 2005, 101 (04): : 978 - 985
  • [33] The rhythmical bursting behaviour of single sympathetic fibres innervating the caudal ventral tail artery in anaesthetized rats is not driven by sensory afferents from the tail
    Smith, JE
    Gilbey, MP
    JOURNAL OF PHYSIOLOGY-LONDON, 1997, 505P : 106P - 106P
  • [34] Estimation of central systolic blood pressure from the digital artery pressure waveform: Comparison of measurements derived directly from the late systolic shoulder and from a transfer function
    Guilcher, A.
    Munir, S.
    Brett, S.
    Clapp, B.
    Redwood, S.
    Chowienczyk, P.
    JOURNAL OF HYPERTENSION, 2007, 25 : S318 - S318
  • [35] COMMON FEMORAL-ARTERY DOPPLER WAVE-FORMS - A COMPARISON OF 3 METHODS OF OBJECTIVE ANALYSIS WITH DIRECT PRESSURE MEASUREMENTS
    MACPHERSON, DS
    EVANS, DH
    BELL, PRF
    BRITISH JOURNAL OF SURGERY, 1984, 71 (01) : 46 - 49
  • [36] Reconstruction of radial artery pressure from non-invasive finger arterial pressure measurements in patients with ischemic heart disease
    Guelen, I
    Bogert, LWJ
    van Beek, M
    Westerhof, BE
    van der Sar, GL
    van Lieshout, JJ
    JOURNAL OF HYPERTENSION, 2004, 22 : S280 - S281
  • [37] Agreement of High-Definition Oscillometry (HDO) and Invasive Blood Pressure Measurements at a Metatarsal Artery in Isoflurane-Anaesthetised Horses
    Twele, Lara
    Neudeck, Stephan
    Delarocque, Julien
    Verhaar, Nicole
    Reiners, Julia
    Noll, Mike
    Tuensmeyer, Julia
    Kaestner, Sabine B. R.
    ANIMALS, 2022, 12 (03):
  • [38] A novel method for the non-invasive estimation of mean pulmonary artery pressure by echocardiography in comparison with right heart catheter measurements
    Chong, A.
    Harrop, D.
    Wahi, S.
    EUROPEAN HEART JOURNAL, 2014, 35 : 290 - 290
  • [39] A COMPARISON OF RESPONSES TO SYMPATHETIC-NERVE STIMULATION AND EXOGENOUS CATECHOLAMINES IN THE CAUDAL ARTERY AND VAS-DEFERENS FROM HYPERTENSIVE AND NORMOTENSIVE RATS
    CASSIS, L
    WESTFALL, D
    STITZEL, RE
    HEAD, RJ
    FEDERATION PROCEEDINGS, 1982, 41 (04) : 1092 - 1092
  • [40] EFFECT OF CHRONIC ADMINISTRATION OF VANADATE ON SYSTOLIC BLOOD-PRESSURE, VASCULAR REACTIVITY, AND NA+-K+-ATPASE ACTIVITY IN ADULT MALE WISTAR RATS
    JADHAV, AL
    JANDHYALA, BS
    FEDERATION PROCEEDINGS, 1982, 41 (05) : 1645 - 1645