Comparison of Invasive Blood Pressure Measurements from the Caudal Ventral Artery and the Femoral Artery in Male Adult SD and Wistar Rats

被引:19
|
作者
Wang, Ying [1 ]
Cong, Yushuang [1 ]
Li, Jun [1 ]
Li, Xueting [1 ]
Li, Bing [2 ]
Qi, Sihua [1 ]
机构
[1] Harbin Med Univ, Affiliated Hosp 4, Dept Anesthesiol, Harbin, Peoples R China
[2] Harbin Med Univ, Affiliated Hosp 2, Dept Nephrol, Harbin, Peoples R China
来源
PLOS ONE | 2013年 / 8卷 / 04期
基金
中国国家自然科学基金;
关键词
TAIL-ARTERY; MODEL; CUFF; AGREEMENT;
D O I
10.1371/journal.pone.0060625
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background and Purpose: Studies have suggested that the caudal ventral artery is a potential site for continuous arterial blood pressure monitoring in rats. However, the agreement of mean arterial pressure values between the femoral artery and the caudal ventral artery has not been investigated. This study was performed to identify whether the caudal ventral artery could be safely used for continuous blood pressure monitoring as an alternative site to the femoral artery. Methods: Rats were randomized into four groups: Sprague Dawley rats under normothermia; Wistar rats under normothermia; Sprague Dawley rats under hypothermia; Wistar rats under hypothermia. Each rat underwent simultaneous monitoring of blood pressure using femoral artery and caudal ventral artery catheterization during a stable hemodynamic state and three periods of acute severe hemodynamic changes. The effects of rat strain, rectal temperature, experimental time course and hemodynamic factors on pressure gradients, the concordance of mean arterial pressure values between the femoral artery and the caudal ventral artery, and the rates of distal ischemia after surgery were determined. Results: There was a significant difference in the rate of distal ischemia between femoral and caudal ventral arteries after catheterization (25% vs 5%, P<0.05). The overall mean gradient and the mean gradient under a steady hemodynamic state were 4.9+/-3.7 mm Hg and 5.5+/-2.5 mm Hg, respectively. The limits of agreement (bias+/-1.96 SD) were (22.5 mm Hg, 12.3 mm Hg) and (-0.5 mm Hg, 10.5 mm Hg), respectively. Although the concordance decreased during the first 30 sec of each period of severe hemodynamic changes, the degree of agreement was acceptable regardless of the effects of rat strain and rectal temperature. Conclusions: Based on the degree of agreement and the safety of catheterization, the caudal ventral artery may be a preferred site for continuous arterial blood pressure monitoring without acute severe hemodynamic changes.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Comparison of the acute effects of Tulbaghia violacea William Henry Harvey (Alliaceae) on blood pressure and heart rate of ageing male normotensive Wistar kyoto rats and adult male spontaneously hypertensive rats
    Raji, Ismaila
    Obikeze, Kenechukwu
    Mugabo, Pierre
    TROPICAL JOURNAL OF PHARMACEUTICAL RESEARCH, 2016, 15 (11) : 2429 - 2434
  • [22] COMPARISON OF ARTERIAL TONOMETRY WITH RADIAL ARTERY CATHETER MEASUREMENTS OF BLOOD-PRESSURE IN ANESTHETIZED PATIENTS
    SIEGEL, LC
    BROCKUTNE, JG
    BRODSKY, JB
    ANESTHESIOLOGY, 1994, 81 (03) : 578 - 584
  • [23] Evaluation of renal artery stenosis:: Comparison of angiography with invasive blood pressure measurement and Doppler ultrasound.
    Sigmund, G
    Hettinger, M
    Blöck, T
    Stölben, A
    Gard, R
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (07): : 615 - 622
  • [24] Agreements between mean arterial pressure from radial and femoral artery measurements in refractory shock patients
    Hemmawan Wisanusattra
    Bodin Khwannimit
    Scientific Reports, 12
  • [25] Agreements between mean arterial pressure from radial and femoral artery measurements in refractory shock patients
    Wisanusattra, Hemmawan
    Khwannimit, Bodin
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [26] Changes in pulse pressure following fluid loading: a comparison between aortic root (non-invasive tonometry) and femoral artery (invasive recordings)
    Nicolas Dufour
    Denis Chemla
    Jean-Louis Teboul
    Xavier Monnet
    Christian Richard
    David Osman
    Intensive Care Medicine, 2011, 37 : 942 - 949
  • [27] Changes in pulse pressure following fluid loading: a comparison between aortic root (non-invasive tonometry) and femoral artery (invasive recordings)
    Dufour, Nicolas
    Chemla, Denis
    Teboul, Jean-Louis
    Monnet, Xavier
    Richard, Christian
    Osman, David
    INTENSIVE CARE MEDICINE, 2011, 37 (06) : 942 - 949
  • [28] EFFECTS OF PROTECTION FROM PRESSURE ON RESISTANCE ARTERY MORPHOLOGY AND REACTIVITY IN SPONTANEOUSLY HYPERTENSIVE AND WISTAR-KYOTO RATS
    BUND, SJ
    WEST, KP
    HEAGERTY, AM
    CIRCULATION RESEARCH, 1991, 68 (05) : 1230 - 1240
  • [29] Clinical agreement of a novel algorithm to estimate radial artery blood pressure from the non-invasive finger blood pressure
    Kho, Eline
    van der Ster, Bjorn J. P.
    van der Ven, Ward H.
    Vlaar, Alexander P. J.
    V. Immink, Rogier
    Veelo, Denise P.
    JOURNAL OF CLINICAL ANESTHESIA, 2022, 83
  • [30] Persistent augmentation of the blood pressure and heart rate responses to dynamic exercise in rats with chronic bilateral femoral artery occlusion
    Kuczmarski, James M.
    Unrath, Kellee
    Thomas, Gail D.
    FASEB JOURNAL, 2016, 30