Comparison of real-time three-dimensional echocardiography with cardiovascular magnetic resonance for left ventricular volumetric assessment in unselected patients

被引:25
|
作者
Miller, Christopher A. [1 ,2 ,3 ]
Pearce, Keith [1 ]
Jordan, Peter [1 ]
Argyle, Rachel [1 ]
Clark, David [4 ]
Stout, Martin [1 ]
Ray, Simon G. [1 ,2 ]
Schmitt, Matthias [1 ,3 ]
机构
[1] Univ S Manchester Hosp, Div Cardiol & Cardiothorac Surg, Manchester M23 9LT, Lancs, England
[2] Univ Manchester, Cardiovasc Res Grp, Manchester, Lancs, England
[3] Univ Manchester, Biomed Imaging Inst, Manchester, Lancs, England
[4] Wythenshawe CMR Unit, Manchester, Lancs, England
基金
美国国家卫生研究院;
关键词
Real time three-dimensional echocardiography; Cardiovascular magnetic resonance; Left ventricle; Image quality; Ejection fraction; MYOCARDIAL-INFARCTION; COMPUTED-TOMOGRAPHY; EJECTION FRACTION; BORDER DETECTION; SINGLE-BEAT; QUANTIFICATION; REPRODUCIBILITY; ACCURACY; CARDIOMYOPATHIES; QUANTITATION;
D O I
10.1093/ejechocard/jer248
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To compare left ventricular (LV) volume indices and the ejection fraction (EF) obtained using real-time three-dimensional echocardiography (RT3DE) and cardiovascular magnetic resonance (CMR) in unselected patients representative of 'real-world' clinical practice, and to determine the effect of RT3DE image quality on these parameters. Methods and results Sixty consecutive patients undergoing CMR underwent same day RT3DE. LV volume and EF measurements were made using both modalities and compared. All scans were independently analysed by a second observer to assess inter-observer variability, and 40% were re-analysed to assess intra-observer variability. RT3DE image quality was graded as good, adequate, and non-analysable. Thirteen (22%) patients had good RT3DE image quality, 29 (48%) had adequate image quality, and 18 (30%) had image quality precluding analysis. Body mass index and arrhythmia frequency were higher in patients with suboptimal image quality. RT3DE significantly underestimated end-diastolic volume (EDV) (-45 +/- 35 mL, P<0.001), end-systolic volume (ESV) (-11 +/- 24 mL, P=0.004), and EF (27 +/- 9%, P<0.001) compared with CMR although the degree of underestimation was substantially less when image quality was good. Eleven patients (18%) classified as having a normal EF by CMR had a reduced EF according to RT3DE, all but one of which had suboptimal image quality. Observer variability for RT3DE was higher than for CMR for all parameters, however, the difference was not significant when RT3DE image quality was good. Conclusions In contrast to previously published data from highly selected patient groups, 'real-world' RT3DE substantially underestimates LV volumes and EF. The degree of underestimation is related to image quality.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 50 条
  • [41] Quantitative Assessment of Left Ventricle by Real-time Three-dimensional Echocardiography
    Lin, Lung-Chun
    Liau, Chiau-Suong
    Lee, Yuan-Teh
    JOURNAL OF MEDICAL ULTRASOUND, 2007, 15 (01) : 19 - 30
  • [42] Measurement of left ventricular volume by real-time, three-dimensional echocardiography in dogs
    Ota, T
    Fleishman, CE
    Ohazama, CJ
    Stetten, G
    Lewis, CW
    Glower, DD
    Li, J
    Ryan, T
    Kisslo, J
    vonRamm, OT
    CIRCULATION, 1996, 94 (08) : 2211 - 2211
  • [43] Quantification of Left Ventricular Systolic Dyssynchrony by Real-Time Three-Dimensional Echocardiography
    Soliman, Osama I. I.
    van Dalen, Bas M.
    Nemes, Attila
    van der Zwaan, Heleen B.
    Vletter, Wim B.
    ten Cate, Folkert J.
    Theuns, Dominic A. M. J.
    Jordaens, Luc J.
    Geleijnse, Marcel L.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (03) : 232 - 239
  • [44] Quantification of left ventricular dyssynchrony in patients with dilated cardiomyopathy by real-time three-dimensional echocardiography
    Zeng, X.
    Shu, X. H.
    Pan, C. Z.
    Chen, R. Z.
    Cheng, K.
    Liu, S. Z.
    Liu, S. Z.
    Chen, H. Z.
    EUROPEAN HEART JOURNAL, 2006, 27 : 535 - 536
  • [45] Assessment of ventricular septal defects by real-time three-dimensional echocardiography and comparison with surgical measurements
    Karadas, Ulas
    Saylam, Gul S.
    Yilmaz, Nuh
    Kir, Mustafa
    Kizilca, Ozgur
    Demircan, Tulay
    Ugurlu, Baran
    Unal, Nurettin
    Demir, And
    PROGRESS IN PEDIATRIC CARDIOLOGY, 2022, 66
  • [46] Assessment of left ventricular function in heart failure: limits of real-time three-dimensional echocardiography in real life
    Moceri, P.
    Bertora, D.
    Gibelin, P.
    EUROPEAN HEART JOURNAL, 2009, 30 : 343 - 343
  • [47] Value of assessment of tricuspid annulus: real-time three-dimensional echocardiography and magnetic resonance imaging
    Ashraf M. Anwar
    Osama I. I. Soliman
    Attila Nemes
    Robert-Jan M. van Geuns
    Marcel L. Geleijnse
    Folkert J. ten Cate
    The International Journal of Cardiovascular Imaging, 2007, 23 : 701 - 705
  • [48] Value of assessment of tricuspid annulus: real-time three-dimensional echocardiography and magnetic resonance imaging
    Anwar, Ashraf M.
    Soliman, Osama I. I.
    Nemes, Attila
    van Geuns, Robert-Jan M.
    Geleijnse, Marcel L.
    ten Cate, Folkert J.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2007, 23 (06): : 701 - 705
  • [49] Comparison by real-time three-dimensional echocardiography of left ventricular geometry in hypertrophic cardiomyopathy versus secondary left ventricular hypertrophy
    Yalçin, F
    Shiota, T
    Odabashian, J
    Agler, D
    Greenberg, NL
    Garcia, MJ
    Lever, HM
    Thomas, JD
    AMERICAN JOURNAL OF CARDIOLOGY, 2000, 85 (08): : 1035 - +
  • [50] Assessment of left ventricular function by real-time three-dimensional echocardiography compared with conventional noninvasive methods
    Takuma, S
    Ota, T
    Muro, T
    Kazanowski, M
    Liu, R
    Yano, H
    Yoshiara, K
    Dimayuga, C
    Makita, K
    Di Tullio, MR
    Yoshikawa, J
    Homma, S
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 469A - 469A