Comparison of real-time three-dimensional echocardiography with cardiovascular magnetic resonance for left ventricular volumetric assessment in unselected patients

被引:25
|
作者
Miller, Christopher A. [1 ,2 ,3 ]
Pearce, Keith [1 ]
Jordan, Peter [1 ]
Argyle, Rachel [1 ]
Clark, David [4 ]
Stout, Martin [1 ]
Ray, Simon G. [1 ,2 ]
Schmitt, Matthias [1 ,3 ]
机构
[1] Univ S Manchester Hosp, Div Cardiol & Cardiothorac Surg, Manchester M23 9LT, Lancs, England
[2] Univ Manchester, Cardiovasc Res Grp, Manchester, Lancs, England
[3] Univ Manchester, Biomed Imaging Inst, Manchester, Lancs, England
[4] Wythenshawe CMR Unit, Manchester, Lancs, England
基金
美国国家卫生研究院;
关键词
Real time three-dimensional echocardiography; Cardiovascular magnetic resonance; Left ventricle; Image quality; Ejection fraction; MYOCARDIAL-INFARCTION; COMPUTED-TOMOGRAPHY; EJECTION FRACTION; BORDER DETECTION; SINGLE-BEAT; QUANTIFICATION; REPRODUCIBILITY; ACCURACY; CARDIOMYOPATHIES; QUANTITATION;
D O I
10.1093/ejechocard/jer248
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To compare left ventricular (LV) volume indices and the ejection fraction (EF) obtained using real-time three-dimensional echocardiography (RT3DE) and cardiovascular magnetic resonance (CMR) in unselected patients representative of 'real-world' clinical practice, and to determine the effect of RT3DE image quality on these parameters. Methods and results Sixty consecutive patients undergoing CMR underwent same day RT3DE. LV volume and EF measurements were made using both modalities and compared. All scans were independently analysed by a second observer to assess inter-observer variability, and 40% were re-analysed to assess intra-observer variability. RT3DE image quality was graded as good, adequate, and non-analysable. Thirteen (22%) patients had good RT3DE image quality, 29 (48%) had adequate image quality, and 18 (30%) had image quality precluding analysis. Body mass index and arrhythmia frequency were higher in patients with suboptimal image quality. RT3DE significantly underestimated end-diastolic volume (EDV) (-45 +/- 35 mL, P<0.001), end-systolic volume (ESV) (-11 +/- 24 mL, P=0.004), and EF (27 +/- 9%, P<0.001) compared with CMR although the degree of underestimation was substantially less when image quality was good. Eleven patients (18%) classified as having a normal EF by CMR had a reduced EF according to RT3DE, all but one of which had suboptimal image quality. Observer variability for RT3DE was higher than for CMR for all parameters, however, the difference was not significant when RT3DE image quality was good. Conclusions In contrast to previously published data from highly selected patient groups, 'real-world' RT3DE substantially underestimates LV volumes and EF. The degree of underestimation is related to image quality.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 50 条
  • [21] Left ventricular dysfunction during right ventricular pacing: volumetric analysis with real-time three-dimensional echocardiography
    Wolber, T.
    Brunckhorst, C.
    Duru, F.
    EUROPEAN HEART JOURNAL, 2009, 30 : 345 - 346
  • [22] Assessment of left ventricular systolic synchronicity by real-time three-dimensional echocardiography in patients with dilated cardiomyopathy
    ZENG Xin SHU Xianhong PAN Cuizhen CHEN Ruizhen CHENG Kuan LIU Shizhen and CHEN Haozhu Department of Echocardiography Zhongshan Hospital of Fudan University Shanghai Institute of Cardiovascular Disease Shanghai China Department of Cardiology Zhongshan Hospital of Fudan University Shanghai Institute of Cardiovascular Disease Shanghai China
    ChineseMedicalJournal, 2006, (11) : 919 - 924
  • [23] Assessment of left ventricular systolic synchronicity by real-time three-dimensional echocardiography in patients with dilated cardiomyopathy
    Zeng Xin
    Shu Xian-Hong
    Pan Cui-Zhen
    Chen Rui-Zhen
    Cheng Kuan
    Liu Shi-Zhen
    Chen Hao-Zhu
    CHINESE MEDICAL JOURNAL, 2006, 119 (11) : 919 - 924
  • [25] Real-time three-dimensional echocardiography with real-time volume rendering in assessment of left ventricular apical thrombi
    Ahmad, M
    Xie, TR
    Chamoun, AJ
    McCulloch, M
    Shah, S
    CIRCULATION, 2002, 106 (13) : E53 - E53
  • [26] Real-time three-dimensional echocardiographic quantification of left ventricular mass: Comparison with magnetic resonance imaging
    Mor-Avi, V
    Sugeng, L
    Caiani, EG
    Weinert, L
    MacEneaney, P
    Salgo, IS
    Lang, RM
    Computers in Cardiology 2004, Vol 31, 2004, 31 : 65 - 68
  • [27] Real-time three-dimensional echocardiography for measurement of left ventricular volumes
    Schmidt, MA
    Ohazama, CJ
    Agyeman, KO
    Freidlin, RZ
    Jones, M
    Laurienzo, JM
    Brenneman, CL
    Arai, AE
    von Ramm, OT
    Panza, JA
    AMERICAN JOURNAL OF CARDIOLOGY, 1999, 84 (12): : 1434 - 1439
  • [28] REAL-TIME THREE-DIMENSIONAL ECHOCARDIOGRAPHY FOR QUANTIFYING LEFT VENTRICULAR MASS
    Hong-wen Fei* Xin-fang Wang
    Chinese Medical Sciences Journal, 2004, (03) : 230 - 232
  • [29] Left ventricular volume estimation for real-time three-dimensional echocardiography
    Corsi, C
    Saracino, G
    Sarti, A
    Lamberti, C
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (09) : 1202 - 1208
  • [30] Left ventricular ejection fraction by real-time three-dimensional echocardiography
    van Dalen, B. M.
    NETHERLANDS HEART JOURNAL, 2014, 22 (09) : 380 - 382