Comparison of real-time three-dimensional echocardiography with cardiovascular magnetic resonance for left ventricular volumetric assessment in unselected patients

被引:25
|
作者
Miller, Christopher A. [1 ,2 ,3 ]
Pearce, Keith [1 ]
Jordan, Peter [1 ]
Argyle, Rachel [1 ]
Clark, David [4 ]
Stout, Martin [1 ]
Ray, Simon G. [1 ,2 ]
Schmitt, Matthias [1 ,3 ]
机构
[1] Univ S Manchester Hosp, Div Cardiol & Cardiothorac Surg, Manchester M23 9LT, Lancs, England
[2] Univ Manchester, Cardiovasc Res Grp, Manchester, Lancs, England
[3] Univ Manchester, Biomed Imaging Inst, Manchester, Lancs, England
[4] Wythenshawe CMR Unit, Manchester, Lancs, England
基金
美国国家卫生研究院;
关键词
Real time three-dimensional echocardiography; Cardiovascular magnetic resonance; Left ventricle; Image quality; Ejection fraction; MYOCARDIAL-INFARCTION; COMPUTED-TOMOGRAPHY; EJECTION FRACTION; BORDER DETECTION; SINGLE-BEAT; QUANTIFICATION; REPRODUCIBILITY; ACCURACY; CARDIOMYOPATHIES; QUANTITATION;
D O I
10.1093/ejechocard/jer248
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims To compare left ventricular (LV) volume indices and the ejection fraction (EF) obtained using real-time three-dimensional echocardiography (RT3DE) and cardiovascular magnetic resonance (CMR) in unselected patients representative of 'real-world' clinical practice, and to determine the effect of RT3DE image quality on these parameters. Methods and results Sixty consecutive patients undergoing CMR underwent same day RT3DE. LV volume and EF measurements were made using both modalities and compared. All scans were independently analysed by a second observer to assess inter-observer variability, and 40% were re-analysed to assess intra-observer variability. RT3DE image quality was graded as good, adequate, and non-analysable. Thirteen (22%) patients had good RT3DE image quality, 29 (48%) had adequate image quality, and 18 (30%) had image quality precluding analysis. Body mass index and arrhythmia frequency were higher in patients with suboptimal image quality. RT3DE significantly underestimated end-diastolic volume (EDV) (-45 +/- 35 mL, P<0.001), end-systolic volume (ESV) (-11 +/- 24 mL, P=0.004), and EF (27 +/- 9%, P<0.001) compared with CMR although the degree of underestimation was substantially less when image quality was good. Eleven patients (18%) classified as having a normal EF by CMR had a reduced EF according to RT3DE, all but one of which had suboptimal image quality. Observer variability for RT3DE was higher than for CMR for all parameters, however, the difference was not significant when RT3DE image quality was good. Conclusions In contrast to previously published data from highly selected patient groups, 'real-world' RT3DE substantially underestimates LV volumes and EF. The degree of underestimation is related to image quality.
引用
收藏
页码:187 / 195
页数:9
相关论文
共 50 条
  • [1] Comparison of real-time three-dimensional echocardiography to magnetic resonance imaging for assessment of-left ventricular mass
    van den Bosch, AE
    Robbers-Visser, D
    Krenning, BJ
    McGhie, JS
    Helbing, WA
    Meijboom, FJ
    Roos-Hesselink, JW
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (01): : 113 - 117
  • [2] Quantification of left ventricular volumes and ejection fraction by real-time three-dimensional echocardiography: comparison with cardiovascular magnetic resonance
    Claver, E.
    Leta, R.
    Pujadas, S.
    Kociubinski, P. A.
    Costa, F. Carreras
    Pons-Llado, G.
    EUROPEAN HEART JOURNAL, 2005, 26 : 314 - 314
  • [3] Quantitative assessment of right ventricular volume and function with real-time three-dimensional echocardiography: comparison with cardiovascular magnetic resonance
    Pamboucas, C.
    Liodakis, E.
    Dawson, D.
    Nihoyannopoulos, P.
    EUROPEAN HEART JOURNAL, 2006, 27 : 859 - 859
  • [4] Quantitative assessment of right ventricular volume and function with real-time three-dimensional echocardiography: Comparison with cardiovascular magnetic resonance
    Liodakis, Emmanouil
    Pamboucas, Constandinos
    Nihoyannopoulos, Petros
    CIRCULATION, 2006, 114 (18) : 369 - 370
  • [5] Comparison of real time 3-dimensional echocardiography with cardiovascular magnetic resonance for left ventricular volumetric assessment - a real world study
    Christopher A Miller
    Keith A Pearce
    Peter Jordan
    Simon G Ray
    Matthias Schmitt
    Journal of Cardiovascular Magnetic Resonance, 12 (Suppl 1)
  • [6] Assessment of left ventricular dyssynchrony by real-time three-dimensional echocardiography
    Delgado, Victoria
    Sitges, Marta
    Vidal, Barbara
    Silva, Etelvino
    Azqueta, Manuel
    Tolosana, Jose M.
    Mont, Lluis
    Pare, Carles
    Brugada, Josep
    REVISTA ESPANOLA DE CARDIOLOGIA, 2008, 61 (08): : 825 - 834
  • [7] Left ventricular mass assessment by real-time three-dimensional echocardiography
    Singh, Anurag
    Pothineni, Koteswara R.
    Panwar, Sadik R.
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 99 (08): : 1180 - 1181
  • [8] Fast measurement of left ventricular mass with real-time three-dimensional echocardiography - Comparison with magnetic resonance imaging
    Mor-Avi, V
    Sugeng, L
    Weinert, L
    MacEneaney, P
    Caiani, EG
    Koch, R
    Salgo, IS
    Lang, RM
    CIRCULATION, 2004, 110 (13) : 1814 - 1818
  • [9] Comparison of cardiovascular magnetic resonance with real-time three-dimensional echocardiography and the right ventricular automated systolic index in the assessment of the right ventricular function
    Florian Andre
    Sebastian Greiner
    Cihan Celik
    Mohamed A Abdelrazek
    Maria Fernanda Braggion Santos
    Dirk Lossnitzer
    Journal of Cardiovascular Magnetic Resonance, 15 (Suppl 1)