Dose reduction and adequate image quality in digital radiography: a contradiction?

被引:0
|
作者
Poetter-Lang, S. [1 ]
Duenkelmeyer, M. [1 ]
Uffmann, M. [2 ]
机构
[1] Med Univ Wien, Univ Klin Radiodiagnost, A-1090 Vienna, Austria
[2] Krankenhaus Neunkirchen, Abt Radiodiagnost, Neunkirchen, Germany
来源
RADIOLOGE | 2012年 / 52卷 / 10期
关键词
Digital detector systems; Dose efficiency; Improved resolution; Quality control; ALARA (as low as reasonably achievable); FLAT-PANEL-DETECTOR; COMPUTED RADIOGRAPHY; CHEST RADIOGRAPHY; AMORPHOUS-SILICON; SCREEN-FILM; PRINCIPLES; PARAMETERS; SYSTEM;
D O I
10.1007/s00117-012-2337-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dose reduction and adequate image quality in digital radiography - a contradiction? Digital radiography has already replaced traditional screen-film systems. Substantial improvements in both dose efficiency and spatial resolution demonstrate the rapid developments in digital radiography. Needle-detector systems have shown up to a 50% dose reduction compared to traditional screen-film systems. There is also a dose reduction capability of up to 50% comparing direct radiography (DR) systems to computed radiography (CR) systems for chest X-rays. However, despite the most recent achievements of CR technology, the dose efficiency of DR systems (caesium iodide flat-panel detector) is unparalleled. The progress in detector technology has contributed to dose reduction and improved image quality, while saving time and providing a higher examination rate. The use of dose indicators and longitudinal dose control are important to avoid substantial accidental dose increase. The dose applied to patients should fall markedly below the defined diagnostic reference levels within the European Union. Regular quality control, as well as continuous education and training of medical and technical personnel, contribute to ensure that the ALARA (as low as reasonably achievable) principle is consistently followed.
引用
收藏
页码:898 / 904
页数:7
相关论文
共 50 条
  • [41] Effects of Projections on Radiation Dose for and Image Quality of Chest Digital Radiography for Children
    Xu, Hongrong
    Liu, Bo
    Cai, Jinhua
    Zheng, Huan
    Zheng, Helin
    Yang, Qiurui
    Yao, Changhong
    [J]. CURRENT MEDICAL IMAGING, 2021, 17 (12) : 1496 - 1502
  • [42] DIAGNOSTIC IMAGE QUALITY AND DOSE REDUCTION USING NIOBIUM FILTRATION FOR CEPHALOMETRIC RADIOGRAPHY
    WAKOH, M
    FARMAN, AG
    KELLY, MS
    KUROYANAGI, K
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 1993, 22 (04) : 189 - 194
  • [43] Digital skeletal radiography - Reduction of absorbed dose by adaptation of exposure factors and image processing
    Axelsson, B
    Petersen, U
    Wiltz, HJ
    [J]. ACTA RADIOLOGICA, 2001, 42 (06) : 592 - 598
  • [44] UTILITY OF DIGITAL RADIOGRAPHY FOR THE SCREENING OF PNEUMOCONIOSIS AS COMPARED TO ANALOG RADIOGRAPHY: RADIATION DOSE, IMAGE QUALITY, AND PNEUMOCONIOSIS CLASSIFICATION
    Lee, Won-Jeong
    Choi, Byung-Soon
    [J]. HEALTH PHYSICS, 2012, 103 (01): : 64 - 69
  • [45] Towards image quality, beam energy and effective dose optimisation in digital thoracic radiography
    Launders, JH
    Cowen, AR
    Bury, RF
    Hawkridge, P
    [J]. EUROPEAN RADIOLOGY, 2001, 11 (05) : 870 - 875
  • [46] Chest radiography: A comparison of image quality and effective dose using four digital systems
    Pascoal, A
    Lawinski, CP
    Mackenzie, A
    Tabakov, S
    Lewis, CA
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 273 - 277
  • [47] Digital chest radiography: an update on modern technology, dose containment and control of image quality
    Cornelia Schaefer-Prokop
    Ulrich Neitzel
    Henk W. Venema
    Martin Uffmann
    Mathias Prokop
    [J]. European Radiology, 2008, 18 : 1818 - 1830
  • [48] Digital chest radiography: an update on modern technology, dose containment and control of image quality
    Schaefer-Prokop, Cornelia
    Neitzel, Ulrich
    Venema, Henk W.
    Uffmann, Martin
    Prokop, Mathias
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (09) : 1818 - 1830
  • [49] Digital radiography: optimization of image quality and dose using multi-frequency software
    Precht, H.
    Gerke, O.
    Rosendahl, K.
    Tingberg, A.
    Waaler, D.
    [J]. PEDIATRIC RADIOLOGY, 2012, 42 (09) : 1112 - 1118
  • [50] Towards image quality, beam energy and effective dose optimisation in digital thoracic radiography
    J. H. Launders
    A. R. Cowen
    R. F. Bury
    P. Hawkridge
    [J]. European Radiology, 2001, 11 : 870 - 875