Dose reduction and adequate image quality in digital radiography: a contradiction?

被引:0
|
作者
Poetter-Lang, S. [1 ]
Duenkelmeyer, M. [1 ]
Uffmann, M. [2 ]
机构
[1] Med Univ Wien, Univ Klin Radiodiagnost, A-1090 Vienna, Austria
[2] Krankenhaus Neunkirchen, Abt Radiodiagnost, Neunkirchen, Germany
来源
RADIOLOGE | 2012年 / 52卷 / 10期
关键词
Digital detector systems; Dose efficiency; Improved resolution; Quality control; ALARA (as low as reasonably achievable); FLAT-PANEL-DETECTOR; COMPUTED RADIOGRAPHY; CHEST RADIOGRAPHY; AMORPHOUS-SILICON; SCREEN-FILM; PRINCIPLES; PARAMETERS; SYSTEM;
D O I
10.1007/s00117-012-2337-9
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Dose reduction and adequate image quality in digital radiography - a contradiction? Digital radiography has already replaced traditional screen-film systems. Substantial improvements in both dose efficiency and spatial resolution demonstrate the rapid developments in digital radiography. Needle-detector systems have shown up to a 50% dose reduction compared to traditional screen-film systems. There is also a dose reduction capability of up to 50% comparing direct radiography (DR) systems to computed radiography (CR) systems for chest X-rays. However, despite the most recent achievements of CR technology, the dose efficiency of DR systems (caesium iodide flat-panel detector) is unparalleled. The progress in detector technology has contributed to dose reduction and improved image quality, while saving time and providing a higher examination rate. The use of dose indicators and longitudinal dose control are important to avoid substantial accidental dose increase. The dose applied to patients should fall markedly below the defined diagnostic reference levels within the European Union. Regular quality control, as well as continuous education and training of medical and technical personnel, contribute to ensure that the ALARA (as low as reasonably achievable) principle is consistently followed.
引用
收藏
页码:898 / 904
页数:7
相关论文
共 50 条
  • [21] Dose-image quality optimisation in digital chest radiography
    Doyle, P
    Martin, CJ
    Gentle, D
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 114 (1-3) : 269 - 272
  • [22] Analyses of patient dose and image quality for chest digital radiography
    Tsai, H. Y.
    Yang, C. H.
    Huang, K. M.
    Li, M. J.
    Tung, C. J.
    [J]. RADIATION MEASUREMENTS, 2010, 45 (3-6) : 722 - 725
  • [23] Image quality assessment with dose reduction using high kVp and additional filtration for abdominal digital radiography
    Jang, Ji Sung
    Yang, Hyung Jin
    Koo, Hyun Jung
    Kim, Sung Ho
    Park, Chan Rok
    Yoon, Suk Hwan
    Shin, So Youn
    Do, Kyung-Hyun
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 50 : 46 - 51
  • [24] REDUCTION OF PATIENT DOSE IN DIGITAL RADIOGRAPHY
    Vaiciunaite, Neringa
    Laurikaitis, Marius
    Adliene, Diana
    [J]. MEDICAL PHYSICS IN THE BALTIC STATES, 2013, : 140 - 142
  • [25] COMPARISON OF WIRELESS DETECTORS FOR DIGITAL RADIOGRAPHY SYSTEMS: IMAGE QUALITY AND DOSE
    Mourik, J. E. M.
    van der Tol, P.
    Veldkamp, W. J. H.
    Geleijns, J.
    [J]. RADIATION PROTECTION DOSIMETRY, 2016, 169 (1-4) : 303 - 307
  • [26] Digital radiography: The balance between image quality and required radiation dose
    Uffmann, Martin
    Schaefer-Prokop, Cornelia
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (02) : 202 - 208
  • [27] Evaluation of dose-image-quality optimization in digital chest radiography
    Lee, S. C.
    Wang, J. N.
    Liu, S. C.
    Jiang, S. H.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 544 - 547
  • [28] Image quality and dose management in digital radiography: A new paradigm for optimisation
    Busch, HP
    Faulkner, K
    [J]. RADIATION PROTECTION DOSIMETRY, 2005, 117 (1-3) : 143 - 147
  • [29] A phantom study of image quality versus radiation dose for digital radiography
    Tung, C. J.
    Tsai, H. Y.
    Shi, M. Y.
    Huang, T. T.
    Yang, C. H.
    Chen, I. J.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (01): : 602 - 605
  • [30] Achievable Radiation Dose Reduction with Comparable Image Quality in Chest Radiography
    Wan, A. Y. H.
    Shih, M. H.
    Lai, B. M. H.
    Chu, C. Y.
    Tang, K. Y. K.
    Chan, R. T. M.
    Khoo, J. L. S.
    [J]. HONG KONG JOURNAL OF RADIOLOGY, 2014, 17 (03): : 182 - 188