Improved Alignment of PET and CT Images in Whole-Body PET/CT in Cases of Respiratory Motion During CT

被引:9
|
作者
Hamill, James J. [1 ]
Meier, Joseph G. [2 ,3 ]
Cuellar, Sonia L. Betancourt [4 ]
Sabloff, Bradley [4 ]
Erasmus, Jeremy J. [4 ]
Mawlawi, Osama [2 ,3 ]
机构
[1] Siemens Med Solut USA Inc, 810 Innovat Dr, Knoxville, TN 37932 USA
[2] MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX USA
[3] Houston Grad Sch Biomed Sci, MD Anderson Canc Ctr, UTHlth Sci Ctr, Houston, TX USA
[4] MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX USA
关键词
PET/CT; respiratory motion; alignment; GATED PET; LUNG; RECONSTRUCTION; QUANTITATION; ARTIFACTS; LESIONS;
D O I
10.2967/jnumed.119.235804
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion during the CT and PET parts of a PET/CT scan leads to imperfect alignment of anatomic features seen by the 2 modalities. In this work, we concentrate on the effects of motion during CT. We propose a novel approach for improving the alignment. Methods: Respiratory waveform data were gathered during the CT and PET parts of 28 PET/CT scans of cancer patients with 40 lesions up to 3 cm in size in the lung or upper abdomen. PET list-mode data were reconstructed by 3 reconstruction methods: PET/static (the standard method with no motion correction); PET/ex (a method that calculates a range of expiratory amplitudes from the lowest one to the highest one); and PET/matched (a novel method that uses both waveforms). The 3 methods were compared. The distance between tumor positions in PET and CT were characterized in visual interpretation by physicians as well as quantitatively. Tumor SUVs (SUVmax and SUVpeak) were determined relative to SUV based on the static method. Image noise was evaluated in the liver and compared with PET/static. Results: In visual interpretation, the rate of good alignment was 13 of 21, 13 of 23, and 18 of 21 for the PET/static, PET/ex, and PET/matched methods, respectively, and the mean PET/CT distances were 3.5, 5.1, and 2.8 mm. In visual comparison with PET/ex, the rate of good alignment was increased in 1 of 10 and 7 of 10 cases for PET/static and PET/matched, respectively. SUVmax was on average 21% higher than PET/static when either PET/ex or PET/matched was used. SUVpeak was 12% higher. Image noise in the liver was 15% higher than PET/static for the PET/ex method, and 40% higher for PET/matched; that is, noise was much lower than in gated PET. Conclusion: Acquiring respiratory waveforms both in PET (as in the current state of the art) and in CT (an unusual key step in this approach) has the potential to improve the alignment of PET and CT images. A proposed method for using this information was tested. Improved alignment was demonstrated.
引用
下载
收藏
页码:1376 / 1380
页数:5
相关论文
共 50 条
  • [41] Respiratory motion artefacts on PET/CT
    Robinson, P
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (12) : 1712 - 1712
  • [42] Respiratory motion artefacts on PET/CT
    Philip Robinson
    Adrian Parkin
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 1712 - 1712
  • [43] Synthetic CT Generation from Non-Attenuation Corrected PET Images for Whole-Body PET Imaging
    Dong, X.
    Lei, Y.
    Wang, T.
    Higgins, K.
    Liu, T.
    Curran, W.
    Mao, H.
    Nye, J.
    Yang, X.
    MEDICAL PHYSICS, 2019, 46 (06) : E113 - E113
  • [44] Automatic tumour delineation in whole body PET/CT images
    Huang, Xiaolei
    Zhu, Yaoyao
    Li, Hongsheng
    Guan, Haiying
    Potesil, Vaclav
    Song, Yulin
    Kubota, Toshiro
    Zhou, Xiang Sean
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2012, 8 (2-3) : 182 - 199
  • [45] Automated Liver Segmentation for Whole-Body Low-Contrast CT Images from PET-CT Scanners
    Wang, Xiuying
    Li, Changyang
    Eberl, Stefan
    Fulham, Michael
    Feng, Dagan
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 3565 - 3568
  • [46] Synthetic CT generation from non-attenuation corrected PET images for whole-body PET imaging
    Dong, Xue
    Wang, Tonghe
    Lei, Yang
    Higgins, Kristin
    Liu, Tian
    Curran, Walter J.
    Mao, Hui
    Nye, Jonathon A.
    Yang, Xiaofeng
    PHYSICS IN MEDICINE AND BIOLOGY, 2019, 64 (21):
  • [47] Impact of Radiation Dose Reduction of CT component in Whole-Body PET/CT Protocols on CT Image quality
    Ali, I.
    Mohamed, Y.
    Naser, I.
    Amin, M. I.
    Gawad, H. Abdel
    Hamdy, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S781 - S782
  • [48] Focused Regional FDG PET/CT Detects More Osseous Metastases Than Does Whole-Body PET/CT
    Mojtahedi, Alireza
    Solomon, Steven B.
    Ulaner, Gary A.
    CLINICAL NUCLEAR MEDICINE, 2013, 38 (03) : 217 - 218
  • [49] Consistency driven respiratory phase alignment and motion compensation in PET/CT
    Alessio, Adam
    Kohlmyer, Steve
    Kinahan, Paul
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3115 - +
  • [50] Clinical comparison of a whole-body PET-MR system with PET-CT
    Machac, Josef
    Izquierdo-Garcia, David
    Knesaurek, Karin
    Rafique, Ash
    Davies, Olufunke
    Fuster, Valentin
    Fayad, Zahi
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53