Improved Alignment of PET and CT Images in Whole-Body PET/CT in Cases of Respiratory Motion During CT

被引:9
|
作者
Hamill, James J. [1 ]
Meier, Joseph G. [2 ,3 ]
Cuellar, Sonia L. Betancourt [4 ]
Sabloff, Bradley [4 ]
Erasmus, Jeremy J. [4 ]
Mawlawi, Osama [2 ,3 ]
机构
[1] Siemens Med Solut USA Inc, 810 Innovat Dr, Knoxville, TN 37932 USA
[2] MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX USA
[3] Houston Grad Sch Biomed Sci, MD Anderson Canc Ctr, UTHlth Sci Ctr, Houston, TX USA
[4] MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX USA
关键词
PET/CT; respiratory motion; alignment; GATED PET; LUNG; RECONSTRUCTION; QUANTITATION; ARTIFACTS; LESIONS;
D O I
10.2967/jnumed.119.235804
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion during the CT and PET parts of a PET/CT scan leads to imperfect alignment of anatomic features seen by the 2 modalities. In this work, we concentrate on the effects of motion during CT. We propose a novel approach for improving the alignment. Methods: Respiratory waveform data were gathered during the CT and PET parts of 28 PET/CT scans of cancer patients with 40 lesions up to 3 cm in size in the lung or upper abdomen. PET list-mode data were reconstructed by 3 reconstruction methods: PET/static (the standard method with no motion correction); PET/ex (a method that calculates a range of expiratory amplitudes from the lowest one to the highest one); and PET/matched (a novel method that uses both waveforms). The 3 methods were compared. The distance between tumor positions in PET and CT were characterized in visual interpretation by physicians as well as quantitatively. Tumor SUVs (SUVmax and SUVpeak) were determined relative to SUV based on the static method. Image noise was evaluated in the liver and compared with PET/static. Results: In visual interpretation, the rate of good alignment was 13 of 21, 13 of 23, and 18 of 21 for the PET/static, PET/ex, and PET/matched methods, respectively, and the mean PET/CT distances were 3.5, 5.1, and 2.8 mm. In visual comparison with PET/ex, the rate of good alignment was increased in 1 of 10 and 7 of 10 cases for PET/static and PET/matched, respectively. SUVmax was on average 21% higher than PET/static when either PET/ex or PET/matched was used. SUVpeak was 12% higher. Image noise in the liver was 15% higher than PET/static for the PET/ex method, and 40% higher for PET/matched; that is, noise was much lower than in gated PET. Conclusion: Acquiring respiratory waveforms both in PET (as in the current state of the art) and in CT (an unusual key step in this approach) has the potential to improve the alignment of PET and CT images. A proposed method for using this information was tested. Improved alignment was demonstrated.
引用
下载
收藏
页码:1376 / 1380
页数:5
相关论文
共 50 条
  • [31] Attenuation correction with extreme CT dose reduction for whole-body FDG PET/CT
    Christopfel, Rebecca
    Byrd, Darrin
    Alessio, Adam
    Asma, Evren
    De Man, Bruno
    Kinahan, Paul
    JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [32] Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT.
    Osman, MM
    Cohade, C
    Wahl, RL
    JOURNAL OF NUCLEAR MEDICINE, 2002, 43 (05) : 305P - 305P
  • [33] Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT
    Medhat M. Osman
    Christian Cohade
    Yuji Nakamoto
    Richard L. Wahl
    European Journal of Nuclear Medicine and Molecular Imaging, 2003, 30 : 603 - 606
  • [34] Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT
    Osman, MM
    Cohade, C
    Nakamoto, Y
    Wahl, RL
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2003, 30 (04) : 603 - 606
  • [35] Body region localization in whole-body low-dose CT images of PET/CT scans using virtual landmarks
    Bai, Peirui
    Udupa, Jayaram K.
    Tong, Yubing
    Xie, ShiPeng
    Torigian, Drew A.
    MEDICAL PHYSICS, 2019, 46 (03) : 1286 - 1299
  • [36] Impact of elastic motion correction on quantitation and image quality of whole-body PET/CT
    Meier, Joseph
    Hamill, James
    Jones, Judson
    Hong, Inki
    Mawlawi, Osama
    JOURNAL OF NUCLEAR MEDICINE, 2017, 58
  • [37] Role of Limited Whole-Body PET/CT in Pediatric Lymphoma
    Sammer, Marla B. K.
    Shulkin, Barry L.
    Alessio, Adam
    Parisi, Marguerite T.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (05) : 1047 - 1055
  • [38] Whole-body tumor burden in PET/CT expert review
    Santos, Dihego F.
    Takahashi, Maria Emilia
    Camacho, Mariana
    Lopes de Lima, Mariana da Cunha
    Amorim, Barbara Juarez
    Rohren, Eric M.
    Etchebehere, Elba
    CLINICAL AND TRANSLATIONAL IMAGING, 2023, 11 (01) : 5 - 22
  • [39] Whole-body tumor burden in PET/CT expert review
    Dihego F. Santos
    Maria Emilia Takahashi
    Mariana Camacho
    Mariana da Cunha Lopes de Lima
    Bárbara Juarez Amorim
    Eric M. Rohren
    Elba Etchebehere
    Clinical and Translational Imaging, 2023, 11 : 5 - 22
  • [40] Implementation and evaluation of a dynamic whole-body PET/CT protocol
    Lodge, Martin
    Rahmim, Arman
    Karakatsanis, Nikolaos
    Zhou, Yun
    Mhlanga, Joyce
    Tahari, Abdel
    Wahl, Richard
    JOURNAL OF NUCLEAR MEDICINE, 2012, 53