Improved Alignment of PET and CT Images in Whole-Body PET/CT in Cases of Respiratory Motion During CT

被引:9
|
作者
Hamill, James J. [1 ]
Meier, Joseph G. [2 ,3 ]
Cuellar, Sonia L. Betancourt [4 ]
Sabloff, Bradley [4 ]
Erasmus, Jeremy J. [4 ]
Mawlawi, Osama [2 ,3 ]
机构
[1] Siemens Med Solut USA Inc, 810 Innovat Dr, Knoxville, TN 37932 USA
[2] MD Anderson Canc Ctr, Dept Imaging Phys, Houston, TX USA
[3] Houston Grad Sch Biomed Sci, MD Anderson Canc Ctr, UTHlth Sci Ctr, Houston, TX USA
[4] MD Anderson Canc Ctr, Dept Diagnost Radiol, Houston, TX USA
关键词
PET/CT; respiratory motion; alignment; GATED PET; LUNG; RECONSTRUCTION; QUANTITATION; ARTIFACTS; LESIONS;
D O I
10.2967/jnumed.119.235804
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Respiratory motion during the CT and PET parts of a PET/CT scan leads to imperfect alignment of anatomic features seen by the 2 modalities. In this work, we concentrate on the effects of motion during CT. We propose a novel approach for improving the alignment. Methods: Respiratory waveform data were gathered during the CT and PET parts of 28 PET/CT scans of cancer patients with 40 lesions up to 3 cm in size in the lung or upper abdomen. PET list-mode data were reconstructed by 3 reconstruction methods: PET/static (the standard method with no motion correction); PET/ex (a method that calculates a range of expiratory amplitudes from the lowest one to the highest one); and PET/matched (a novel method that uses both waveforms). The 3 methods were compared. The distance between tumor positions in PET and CT were characterized in visual interpretation by physicians as well as quantitatively. Tumor SUVs (SUVmax and SUVpeak) were determined relative to SUV based on the static method. Image noise was evaluated in the liver and compared with PET/static. Results: In visual interpretation, the rate of good alignment was 13 of 21, 13 of 23, and 18 of 21 for the PET/static, PET/ex, and PET/matched methods, respectively, and the mean PET/CT distances were 3.5, 5.1, and 2.8 mm. In visual comparison with PET/ex, the rate of good alignment was increased in 1 of 10 and 7 of 10 cases for PET/static and PET/matched, respectively. SUVmax was on average 21% higher than PET/static when either PET/ex or PET/matched was used. SUVpeak was 12% higher. Image noise in the liver was 15% higher than PET/static for the PET/ex method, and 40% higher for PET/matched; that is, noise was much lower than in gated PET. Conclusion: Acquiring respiratory waveforms both in PET (as in the current state of the art) and in CT (an unusual key step in this approach) has the potential to improve the alignment of PET and CT images. A proposed method for using this information was tested. Improved alignment was demonstrated.
引用
收藏
页码:1376 / 1380
页数:5
相关论文
共 50 条
  • [1] Whole-body PET angiography on semiconductor PET/CT
    Takashi Norikane
    Yuka Yamamoto
    Yasukage Takami
    Katsuya Mitamura
    Keisuke Matsumoto
    Yukito Maeda
    Yoichi Yamashita
    Yoshihiro Nishiyama
    [J]. Journal of Nuclear Cardiology, 2022, 29 : 885 - 888
  • [2] Whole-body PET angiography on semiconductor PET/CT
    Norikane, Takashi
    Yamamoto, Yuka
    Takami, Yasukage
    Mitamura, Katsuya
    Matsumoto, Keisuke
    Maeda, Yukito
    Yamashita, Yoichi
    Nishiyama, Yoshihiro
    [J]. JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (02) : 885 - 888
  • [3] Automatic anatomy recognition in whole-body PET/CT images
    Wang, Huiqian
    Udupa, Jayaram K.
    Odhner, Dewey
    Tong, Yubing
    Zhao, Liming
    Torigian, Drew A.
    [J]. MEDICAL PHYSICS, 2016, 43 (01) : 613 - 629
  • [4] Effect of Patient Arm Motion in Whole-Body PET/CT
    Lodge, Martin A.
    Mhlanga, Joyce C.
    Cho, Steve Y.
    Wahl, Richard L.
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (12) : 1891 - 1897
  • [5] Effect of patient arm motion in whole-body PET/CT
    Lodge, Martin
    Mhlanga, Joyce
    Wahl, Richard
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [6] Whole-body Doses to Technologists Working with PET and PET/CT
    Svalling, S.
    Jorgensen, H.
    Holm, S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S290 - S290
  • [7] Automation of respiratory amplitude gating in whole-body PET/CT imaging
    Chang, Guoping
    Pan, Tinsu
    Chang, Tingting
    Rohren, Eric
    Clark, John
    Mawlawi, Osama
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [8] Elastic Motion Correction For Continuous Bed Motion Whole-body PET/CT
    Hong, Inki
    Jones, Judson
    Hamill, James
    Michel, Christian
    Casey, Michael
    [J]. 2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [9] CT Radiation Dose Optimization in Whole-Body PET/CT Examination
    Tonkopi, E.
    Ross, A.
    MacDonald, A.
    [J]. MEDICAL PHYSICS, 2010, 37 (06)
  • [10] Whole-body dynamic imaging with continuous bed motion PET/CT
    Osborne, Dustin R.
    Acuff, Shelley
    [J]. NUCLEAR MEDICINE COMMUNICATIONS, 2016, 37 (04) : 428 - 431