Effects of Flow-Diverting Device Oversizing on Hemodynamics Alteration in Cerebral Aneurysms

被引:73
|
作者
Mut, F. [1 ]
Cebral, J. R. [1 ]
机构
[1] George Mason Univ, Ctr Computat Fluid Dynam, Coll Sci, Fairfax, VA 22030 USA
关键词
INTRACRANIAL ANEURYSMS; RECONSTRUCTION; EXPERIENCE; PIPELINE; STENT;
D O I
10.3174/ajnr.A3080
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: Flow-diverting devices are increasingly being considered for large or giant aneurysms with wide necks, which are difficult to treat with coils or clips. These devices are often oversized to achieve good positioning against the artery wall. The objective of this study was to analyze the effect of oversized flow-diverting devices in altering aneurysmal flows and creating hemodynamic environments favorable for thrombosis and aneurysm occlusion. MATERIALS AND METHODS: Patient-specific computational fluid dynamics models of 3 cerebral aneurysms were constructed from 3D angiography images. Numeric simulations of the hemodynamics after implanting stents of increasing diameters were performed. The corresponding modifications of hemodynamic variables such as aneurysm inflow rate, average velocity, shear rate, and wall shear stress were calculated and compared. RESULTS: The results indicate that because the devices are oversized, the stent cells stretch in the direction of the vessel axis, change cell angles, and result in larger cells. This change in the cell geometry causes a diminution of the hemodynamic performance of the stent. Quantitatively, stent oversizing results in larger values of aneurysm inflow rates, average velocity, shear rate, and wall shear stress compared with nonoversizing cases. CONCLUSIONS: The efficacy of flow-diverting devices in modifying intra-aneurysmal flow can be substantially reduced by oversizing the devices. As the level of device oversize increases, aneurysmal hemodynamic variables are significantly less affected.
引用
收藏
页码:2010 / 2016
页数:7
相关论文
共 50 条
  • [31] Letter Regarding Article, "Efficacy of Flow-Diverting Devices for Cerebral Aneurysms: A Systematic Review and Meta-analysis"
    Arrese, Ignacio
    Sarabia, Rosario
    WORLD NEUROSURGERY, 2016, 94 : 578 - 578
  • [32] Complex cerebral aneurysms: intra-luminal reconstruction using Pipeline flow-diverting stent and the obliteration mechanism
    Lv, Xianli
    Jiang, Chuhan
    Wu, Zhongxue
    Jiang, Weijian
    Wang, Guihuai
    NEURORADIOLOGY JOURNAL, 2020, 33 (02): : 91 - 97
  • [33] A computational model based on fibrin accumulation for the prediction of stasis thrombosis following flow-diverting treatment in cerebral aneurysms
    Chubin Ou
    Wei Huang
    Matthew Ming-Fai Yuen
    Medical & Biological Engineering & Computing, 2017, 55 : 89 - 99
  • [34] A computational model based on fibrin accumulation for the prediction of stasis thrombosis following flow-diverting treatment in cerebral aneurysms
    Ou, Chubin
    Huang, Wei
    Yuen, Matthew Ming-Fai
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (01) : 89 - 99
  • [35] Analysis of Hemodynamics and Aneurysm Occlusion after Flow-Diverting Treatment in Rabbit Models
    Cebral, J. R.
    Mut, F.
    Raschi, M.
    Hodis, S.
    Ding, Y. -H.
    Erickson, B. J.
    Kadirvel, R.
    Kallmes, D. F.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2014, 35 (08) : 1567 - 1573
  • [36] Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent
    Pieper, Claus Christian
    Meyer, Carsten
    Rudolph, Jens
    Verrel, Frauke
    Schild, Hans Heinz
    Wilhelm, Kai E.
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2013, 36 (04) : 917 - 925
  • [37] Small Unruptured Intracranial Aneurysms Can Be Effectively Treated With Flow-Diverting Devices
    Li, Li
    Gao, Bu-Lang
    Shao, Qiu-Ji
    Zhang, Guang-Lin
    Wang, Zi-Liang
    Li, Tian-Xiao
    Zhu, Liang-Fu
    FRONTIERS IN NEUROLOGY, 2022, 13
  • [38] Analyzing the Safety and Efficacy of Flow-Diverting Stents in Pediatric Aneurysms: A Systematic Review
    Scoville, Jonathan
    Joyce, Evan
    Baker, Cordell
    Dewey, Jesse
    Grandhi, Ramesh
    Taussky, Philipp
    NEUROSURGERY, 2021, 89 (02) : 154 - 163
  • [39] Interventional Exclusion of Iliac Artery Aneurysms Using the Flow-Diverting Multilayer Stent
    Claus Christian Pieper
    Carsten Meyer
    Jens Rudolph
    Frauke Verrel
    Hans Heinz Schild
    Kai E. Wilhelm
    CardioVascular and Interventional Radiology, 2013, 36 : 917 - 925
  • [40] Flow-Diverting Stents for the Obliteration of Symptomatic, Infectious Cavernous Carotid Artery Aneurysms
    Kobets, Andrew Joshua
    Scoco, Aleka
    Nakhla, Jonathan
    Brook, Allan Leonard
    Kinon, Merritt Drew
    Baxi, Nrupen
    Altschul, David
    OPERATIVE NEUROSURGERY, 2018, 14 (06) : 681 - 685