AMS of 36Cl with the VERA 3 MV tandem accelerator

被引:17
|
作者
Martschini, Martin [1 ]
Andersson, Pontus [1 ]
Forstner, Oliver [1 ]
Golser, Robin [1 ]
Hanstorp, Dag [2 ]
Lindahl, Anton O. [2 ]
Kutschera, Walter [1 ]
Pavetich, Stefan [1 ]
Priller, Alfred [1 ]
Rohlen, Johan [2 ]
Steier, Peter [1 ]
Suter, Martin [3 ]
Wallner, Anton [1 ]
机构
[1] Univ Vienna, Fac Phys Isotope Res, VERA Lab, A-1090 Vienna, Austria
[2] Univ Gothenburg, Dept Phys, SE-41296 Gothenburg, Sweden
[3] ETH, Dept Phys, CH-8093 Zurich, Switzerland
关键词
AMS; Cl-36; Isobar separation; Energy loss straggling; Cesium sputter ion source; COSMOGENIC CL-36; IONS;
D O I
10.1016/j.nimb.2012.01.055
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent progress with compact ionization chambers has opened new possibilities for isobar suppression in accelerator mass spectrometry (AMS). Separation of Cl-36 (t(1/2) = 0.30 Ma) at natural isotopic levels from its stable isobar S-36 became feasible at particle energies of 24 MeV, which are also accessible for medium-sized tandem accelerators with 3 MV terminal voltage like VERA (Vienna Environmental Research Accelerator). Investigations with an ionization chamber revealed how physics favors isobar separation even at energies below the maximum of the Bragg curve. The strong energy focusing effect at high energy losses reduces energy straggling significantly and isobar separation steadily increases up to almost full energy loss. With an optimized detection setup, sulfur suppression factors of 2 x 10(4) have been achieved. Refraining from the additional use of degrader foils has the benefit of high transmission to the detector (similar to 16%), but requires a low sulfur output from the ion source. Therefore several backing materials have been screened for sulfur content. The dependence of the sulfur output on the AgCl sample size has been investigated as well. Precision and accuracy have been thoroughly assessed over the last two years. Since drifts in the spectra are efficiently corrected by monitoring the position of the S-36 peak, the reproducibility for high ratio samples (Cl-36/Cl > 10(-12)) is better than 2%. Our blank value of Cl-36/Cl approximate to (5 +/- 5) x 10(-16) is competitive to other labs. Cl-36 has become a routine AMS-isotope at VERA. Recently we also explored novel techniques for additional sulfur suppression already in the ion source. While results with a small gas reaction cell in front of the sputter target were discouraging, a decrease in the sulfur/chlorine ratio by one order of magnitude was achieved by directing 300 mW continuous wave laser beam at 445 nm towards the cathode in the ion source. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 50 条
  • [41] Ultra-trace analysis of 36Cl by accelerator mass spectrometry: an interlaboratory study
    Merchel, S.
    Bremser, W.
    Alfimov, V.
    Arnold, M.
    Aumaitre, G.
    Benedetti, L.
    Bourles, D. L.
    Caffee, M.
    Fifield, L. K.
    Finkel, R. C.
    Freeman, S. P. H. T.
    Martschini, M.
    Matsushi, Y.
    Rood, D. H.
    Sasa, K.
    Steier, P.
    Takahashi, T.
    Tamari, M.
    Tims, S. G.
    Tosaki, Y.
    Wilcken, K. M.
    Xu, S.
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 400 (09) : 3125 - 3132
  • [42] STUDY OF AN ORIGIN OF 36Cl NUCLEI IN THE NATURE——36Ar(n, p)36Cl REACTION
    蒋崧生
    黄斐增
    ChineseScienceBulletin, 1992, (14) : 1200 - 1202
  • [43] Methodological study on exposure date of Tiankeng by AMS measurement of in situ produced cosmogenic 36Cl
    Kejun, Dong
    Li Shizhuo
    Ming, He
    Sasa, Kimikazu
    Matsushi, Yuki
    Baojian, Huang
    Ruan Xiangdong
    Guan Yongjing
    Takahashi, Tsutomu
    Sueki, Keisuke
    Li Chaoli
    Wu Shaoyong
    Wang Xianggao
    Shen Hongtao
    Nagashima, Yasuo
    Shan, Jiang
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2013, 294 : 611 - 615
  • [44] 通过36Cl的AMS测定研究灰岩的侵蚀速率
    汪越
    Y.Nagashima
    R.Seki
    刘存富
    武绍勇
    仇九子
    何明
    吴伟明
    姜山
    物理实验, 2005, (03) : 11 - 14
  • [45] ACCELERATOR MASS SPECTROMETRY OF 36Cl, 129I AND 187Os.
    Kubik, P.W.
    Elmore, D.
    Fehn, U.
    Phillips, F.M.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1986, B24-25 (pt 2 Apr III) : 676 - 681
  • [46] Ultra-trace analysis of 36Cl by accelerator mass spectrometry: an interlaboratory study
    S. Merchel
    W. Bremser
    V. Alfimov
    M. Arnold
    G. Aumaître
    L. Benedetti
    D. L. Bourlès
    M. Caffee
    L. K. Fifield
    R. C. Finkel
    S. P. H. T. Freeman
    M. Martschini
    Y. Matsushi
    D. H. Rood
    K. Sasa
    P. Steier
    T. Takahashi
    M. Tamari
    S. G. Tims
    Y. Tosaki
    K. M. Wilcken
    S. Xu
    Analytical and Bioanalytical Chemistry, 2011, 400 : 3125 - 3132
  • [47] MEASUREMENT OF COSMOGENIC 36Cl/Cl IN YOUNG VOLCANIC ROCKS: AN APPLICATION OF ACCELERATOR MASS SPECTROMETRY IN GEOCHRONOLOGY.
    Leavy, B.D.
    Phillips, F.M.
    Elmore, D.
    Kubik, P.W.
    Gladney, E.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1987, B29 (1-2) : 246 - 250
  • [48] AMS WITH THE UPPSALA EN TANDEM ACCELERATOR
    POSSNERT, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1984, 5 (02): : 159 - 161
  • [49] 36Cl in modern atmospheric precipitation
    Faculty of Physics, Technical University of Munich, Garching, Germany
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    不详
    Geophys Res Lett, 10 (1401-1404):
  • [50] GEOLOGISCHE ALTERSBESTIMMUNG MIT 36CL
    BAGGE, E
    WILLKOMM, H
    ATOMKERNENERGIE, 1966, 11 (5-6): : 176 - &