AMS of 36Cl with the VERA 3 MV tandem accelerator

被引:17
|
作者
Martschini, Martin [1 ]
Andersson, Pontus [1 ]
Forstner, Oliver [1 ]
Golser, Robin [1 ]
Hanstorp, Dag [2 ]
Lindahl, Anton O. [2 ]
Kutschera, Walter [1 ]
Pavetich, Stefan [1 ]
Priller, Alfred [1 ]
Rohlen, Johan [2 ]
Steier, Peter [1 ]
Suter, Martin [3 ]
Wallner, Anton [1 ]
机构
[1] Univ Vienna, Fac Phys Isotope Res, VERA Lab, A-1090 Vienna, Austria
[2] Univ Gothenburg, Dept Phys, SE-41296 Gothenburg, Sweden
[3] ETH, Dept Phys, CH-8093 Zurich, Switzerland
关键词
AMS; Cl-36; Isobar separation; Energy loss straggling; Cesium sputter ion source; COSMOGENIC CL-36; IONS;
D O I
10.1016/j.nimb.2012.01.055
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Recent progress with compact ionization chambers has opened new possibilities for isobar suppression in accelerator mass spectrometry (AMS). Separation of Cl-36 (t(1/2) = 0.30 Ma) at natural isotopic levels from its stable isobar S-36 became feasible at particle energies of 24 MeV, which are also accessible for medium-sized tandem accelerators with 3 MV terminal voltage like VERA (Vienna Environmental Research Accelerator). Investigations with an ionization chamber revealed how physics favors isobar separation even at energies below the maximum of the Bragg curve. The strong energy focusing effect at high energy losses reduces energy straggling significantly and isobar separation steadily increases up to almost full energy loss. With an optimized detection setup, sulfur suppression factors of 2 x 10(4) have been achieved. Refraining from the additional use of degrader foils has the benefit of high transmission to the detector (similar to 16%), but requires a low sulfur output from the ion source. Therefore several backing materials have been screened for sulfur content. The dependence of the sulfur output on the AgCl sample size has been investigated as well. Precision and accuracy have been thoroughly assessed over the last two years. Since drifts in the spectra are efficiently corrected by monitoring the position of the S-36 peak, the reproducibility for high ratio samples (Cl-36/Cl > 10(-12)) is better than 2%. Our blank value of Cl-36/Cl approximate to (5 +/- 5) x 10(-16) is competitive to other labs. Cl-36 has become a routine AMS-isotope at VERA. Recently we also explored novel techniques for additional sulfur suppression already in the ion source. While results with a small gas reaction cell in front of the sputter target were discouraging, a decrease in the sulfur/chlorine ratio by one order of magnitude was achieved by directing 300 mW continuous wave laser beam at 445 nm towards the cathode in the ion source. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:115 / 120
页数:6
相关论文
共 50 条
  • [21] 36Cl STUDIES AT THE ETH/SIN-AMS FACILITY.
    Suter, M.
    Beer, J.
    Bonani, G.
    Hofmann, H.J.
    Michel, D.
    Oeschger, H.
    Synal, H.A.
    Woefli, W.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1987, B29 (1-2) : 211 - 215
  • [22] 36Cl measurements with a gas-filled magnet at 6 MV
    Vockenhuber, Christof
    Miltenberger, Klaus-Ulrich
    Synal, Hans-Arno
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 455 : 190 - 194
  • [23] Improvement of pre-treatment method for 36Cl/Cl measurement of Cl in natural groundwater by AMS
    Nakata, Kotaro
    Hasegawa, Takuma
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2011, 269 (03): : 300 - 307
  • [24] Isobar suppression for 36Cl accelerator mass spectrometry at the University of Tsukuba
    Hosoya, Seiji
    Sasa, Kimikazu
    Takahashi, Tsutomu
    Matsunaka, Tetsuya
    Matsumura, Masumi
    Shen, Hongtao
    Ota, Yuki
    Takano, Kenta
    Ochiai, Yuta
    Sueki, Keisuke
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2019, 438 : 131 - 135
  • [25] CONVENIENT METHOD FOR PREPARATION OF [36CL]CHLORINE FROM [36CL]HYDROCHLORIC ACID - DECOMPOSITION OF PALLADOUS [36CL]CHLORIDE
    MCNEILL, IC
    JOURNAL OF THE CHEMICAL SOCIETY, 1961, (FEB): : 639 - &
  • [26] Decadal 10Be, 26Al and 36Cl QA measurements on the SUERC 5 MV accelerator mass spectrometer
    Xu, Sheng
    Freeman, Stewart P. H. T.
    Rood, Dylan H.
    Shanks, Richard P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 361 : 39 - 42
  • [27] He stripping for AMS of 236U and other actinides using a 3 MV tandem accelerator
    Winkler, Stephan R.
    Steier, Peter
    Buchriegler, Josef
    Lachner, Johannes
    Pitters, Johanna
    Priller, Alfred
    Golser, Robin
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2015, 361 : 458 - 464
  • [28] Isotope Dilution-AMS technique for 36Cl and Cl determination in low chlorine content waters
    Bouchez, Camille
    Pupier, Julie
    Benedetti, Lucilla
    Deschamps, Pierre
    Guillou, Valery
    Keddadouche, Karim
    Aumaitre, Georges
    Arnold, Maurice
    Bourles, Didier
    CHEMICAL GEOLOGY, 2015, 404 : 62 - 70
  • [29] The Naples University 3 MV Tandem Accelerator
    Campajola, L.
    Brondi, A.
    MULTIDISCIPLINARY APPLICATIONS OF NUCLEAR PHYSICS WITH ION BEAMS (ION BEAMS '12), 2013, 1530 : 58 - 65
  • [30] 26Al and 36Cl AMS system at the University of Tsukuba:: A progress report
    Sasa, Kimikazu
    Nagashima, Yasuo
    Takahashi, Tsutomu
    Seki, Riki
    Tosaki, Yuki
    Sueki, Keisuke
    Bessho, Kotaro
    Matsumura, Hiroshi
    Miura, Taichi
    He, Ming
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 259 (01): : 41 - 46