Significant reduction of radiation exposure to operator and staff during cardiac interventions by analysis of radiation leakage and improved lead shielding

被引:99
|
作者
Kuon, E
Schmitt, M
Dahm, JB
机构
[1] Klin Frank Schweiz, Dept Cardiol, D-91320 Ebermannstadt, Germany
[2] Univ Erlangen Nurnberg, Ctr Diagnost Radiol, Erlangen, Germany
[3] Ernst Moritz Arndt Univ Greifswald, Dept Internal Med, Greifswald, Germany
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2002年 / 89卷 / 01期
关键词
D O I
10.1016/S0002-9149(01)02161-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objectives of this study were to disclose and to reduce occupational radiation leakage in invasive cardiology. prospectively, we analyzed various dose parameters for 330 coronary procedures. We used a Rando phantom to measure scatter entrance skin air kerma to the operator (S-ESAK-O) during fluoroscopy for all standard tube angulations, and to plot isodose lines for 0degrees/0degrees-posterior anterior angulation. The patient's measured dose area product due to diagnostic catheterization and elective percutaneous transluminal coronary angioplasty was 6.2 and 10.4 Gycm(2), which represents 11% and 13% of currently typical values, respectively. With use of 0.5- and 1.0-mm overcouch and undercouch shielding, it was possible to reduce the mean of 4,686 nSv/Gycm(2) to 677 and 277 nSv/Gycm(2), respectively. Closure of radiation leakage up to 897 muSv/hour at the operator's gonadal height (80 to 105 cm), not heretofore described, was achieved by an additional 1.0-mm, lead-equivalent undercouch-top and overcouch-flop adjacent to the table, down to a S-ESAKO/dose area product level of 47.5 nSv/Gycm(2). With use of a 0.5-mm lead apron, collar, glasses, foot-switch shield and 1.0-mm lead cover around the patient's thighs, the operator received a mean S-ESAK-O of 8.5, while his forehead, eyes, thyroid, chest, gonads, and hands were exposed to 68.2, 1.2, 1.2, 1.2, 0.8, and 58.2 nSv/Gycm(2), respectively. In conclusion, radiation-attenuating intervention techniques and improved lead protection can effectively contribute to a new state of the art in invasive cardiology, with reduction of operator radiation exposure to 0.8% of typical S-ESAK-O levels in advanced catheterization laboratories. (C) 2002 by Excerpta Medica, Inc.
引用
收藏
页码:44 / 49
页数:6
相关论文
共 50 条
  • [41] RADIATION EXPOSURE AND EFFICACY OF EXPOSURE-REDUCTION TECHNIQUES DURING CARDIAC-CATHETERIZATION IN CHILDREN
    SCHUELER, BA
    JULSRUD, PR
    GRAY, JE
    STEARS, JG
    WU, KY
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 173 - 177
  • [42] A Radiation Dose Reduction Technology to Improve Patient Safety During Cardiac Catheterization Interventions
    Bracken, John A.
    Mauti, Maria
    Kim, Michael S.
    Messenger, John C.
    Carroll, John D.
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2015, 28 (05) : 493 - 497
  • [43] RADIATION EXPOSURE TO STAFF CARDIOLOGIST VS SENIOR RESIDENT CARDIOLOGIST AND PATIENTS DURING CARDIAC CATHETERIZATION
    MALSKY, SJ
    HAYT, D
    ROSWIT, B
    SIMON, DF
    BLATT, C
    GOULD, L
    HAFT, J
    RADIATION DATA AND REPORTS, 1972, 13 (07) : 387 - &
  • [44] Radiation Dose Reduction during Radial Cardiac Catheterization: Evaluation of a New Absorption Shielding Drape
    Nadelson, Jeffrey
    Ertel, Andrew
    Ferrera, Dean
    Sweis, Ranya N.
    Shroff, Adhir R.
    Vidovich, Mladen I.
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2011, 58 (20) : B163 - B163
  • [45] Radiation protection during cardiac catherization: development of an improved lead apron for periinterventional echocardiography
    Bogunovic, N.
    Horstkotte, D.
    Faber, L.
    Bogunovic, L.
    Van Buuren, F.
    MINERVA CARDIOANGIOLOGICA, 2015, 63 (05): : 458 - 460
  • [46] Operator Radiation Exposure and Physical Discomfort During a Right Versus Left Radial Approach for Coronary Interventions
    Kado, Herman
    Patel, Ambar M.
    Suryadevara, Siva
    Zenni, Martin M.
    Box, Lyndon C.
    Angiolillo, Dominick J.
    Bass, Theodore A.
    Guzman, Luis A.
    JACC-CARDIOVASCULAR INTERVENTIONS, 2014, 7 (07) : 810 - 816
  • [47] Significant reduction of radiation exposure during ablation can be achieved by simple dose limitation manoeuvres
    Rogers, Dominic P.
    England, Fiona
    Dhinoja, Mehul
    Lowe, Martin D.
    Lambiase, Pier D.
    Chow, Anthony W.
    CIRCULATION, 2006, 114 (18) : 704 - 704
  • [48] Breast Surface Radiation Dose During Coronary CT Angiography: Reduction by Breast Displacement and Lead Shielding
    Foley, Shane J.
    McEntee, Mark F.
    Achenbach, Stephan
    Brennan, Patrick C.
    Rainford, Louise S.
    Dodd, Jonathan D.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (02) : 367 - 373
  • [49] Effectiveness of a New Lead-Shielding Device and Additional Filter for Reducing Staff and Patient Radiation Exposure During Videofluoroscopic Swallowing Study Using a Human Phantom
    Yoshiaki Morishima
    Koichi Chida
    Yoshikazu Muroya
    Yoshiya Utsumi
    Dysphagia, 2018, 33 : 109 - 114
  • [50] Effectiveness of a New Lead-Shielding Device and Additional Filter for Reducing Staff and Patient Radiation Exposure During Videofluoroscopic Swallowing Study Using a Human Phantom
    Morishima, Yoshiaki
    Chida, Koichi
    Muroya, Yoshikazu
    Utsumi, Yoshiya
    DYSPHAGIA, 2018, 33 (01) : 109 - 114