Safety and Efficacy of a Bolus Injection of Landiolol Hydrochloride as a Premedication for Multidetector-Row Computed Tomography Coronary Angiography

被引:22
|
作者
Osawa, Kazuhiro [1 ]
Miyoshi, Toru [2 ]
Sato, Shuhei [3 ]
Akagi, Noriaki [3 ]
Morimitsu, Yusuke [3 ]
Nakamura, Kazufumi [1 ]
Kohno, Kunihisa [1 ]
Kusano, Kengo [1 ]
Kanazawa, Susumu [3 ]
Ito, Hiroshi [1 ]
机构
[1] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Cardiovasc Med, Okayama 7008558, Japan
[2] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Cardiovasc Therapeut, Okayama 7008558, Japan
[3] Okayama Univ, Grad Sch Med Dent & Pharmaceut Sci, Dept Radiol, Okayama 7008558, Japan
关键词
beta-blocker; Coronary angiography; Landiolol; Multidetector-row computed tomography; ATRIAL-FIBRILLATION; BETA-BLOCKER; NONINVASIVE ASSESSMENT; CARDIAC-FUNCTION; ARTERY-DISEASE; IMAGE QUALITY; CT; ESMOLOL;
D O I
10.1253/circj.CJ-12-0663
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: We evaluated the safety and efficacy of a bolus injection of landiolol hydrochloride, an ultrashort-acting beta 1-selective antagonist, as an additional treatment after premedication with an oral p-blocker to reduce heart rate prior to multidetector-row computed tomography (MDCT) coronary angiography (CAG). Methods and Results: A total of 458 patients who underwent MDCT CAG were retrospectively enrolled. Image quality and hemodynamic parameters were compared in patients before and after approval of landiolol hydrochloride. If heart rate reduction was insufficient after premedication with an oral beta-blocker, a bolus injection of landiolol hydrochloride (n=66) or other drugs (n=30) was used. The percentage of evaluable images per segment in patients after approval of landiolol (99.3%) was greater than that in patients before approval of landiolol (97.4%, P<0.01). Heart rates before scanning in patients receiving landiolol hydrochloride were similar to those receiving other drugs. Heart rate was significantly reduced approximately 5 min after injection of landiolol hydrochloride and increased shortly. No decrease in systolic blood pressure or other adverse effects was observed. Conclusions: Bolus injection of landiolol hydrochloride sufficiently reduced heart rate without significantly reducing systolic blood pressure and produced a high percentage of evaluable images, suggesting that bolus injection of landiolol hydrochloride as an additional pretreatment is feasible in MDCT CAG. (Circ J 2013; 77:146-152)
引用
收藏
页码:146 / 152
页数:7
相关论文
共 50 条
  • [41] Current Contrast Media Delivery Strategies for Cardiac and Pulmonary Multidetector-row Computed Tomography Angiography
    Ramos-Duran, Luis R.
    Kalafut, John F.
    Hanley, Michael
    Schoepf, U. Joseph
    JOURNAL OF THORACIC IMAGING, 2010, 25 (04) : 270 - 277
  • [42] Anatomic Variations in Branching Patterns of the Axillary Artery: A Multidetector-Row Computed Tomography Angiography Study
    Hattori, Yasunori
    Doi, Kazuteru
    Sakamoto, Soutetsu
    Satbhai, Nilesh
    JOURNAL OF RECONSTRUCTIVE MICROSURGERY, 2013, 29 (08) : 531 - 536
  • [43] Coronary artery calcification scoring by prospectively triggered multidetector-row computed tomography - Is it reproducible?
    Lawler, LP
    Horton, KM
    Scatarige, JC
    Phelps, J
    Thompson, RE
    Choi, L
    Fishman, EK
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (01) : 40 - 45
  • [44] Visualization of extracranial-intracranial bypass using multidetector-row helical computed tomography angiography
    Tsuchiya, K
    Aoki, C
    Katase, S
    Hachiya, J
    Shiokawa, Y
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2003, 27 (02) : 231 - 234
  • [45] Assessment of myocardial infarctions using multidetector-row computed tomography
    Nikolaou, K
    Knez, A
    Sagmeister, S
    Wintersperger, BJ
    Boekstegers, P
    Steinbeck, G
    Reiser, MF
    Becker, CR
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2004, 28 (02) : 286 - 292
  • [46] Multiple Tracheal Diverticula Detected by Multidetector-row Computed Tomography
    Wakisaka, Masaki
    Sohma, Wataru
    Abe, Hisanori
    Kawano, Yuichiro
    Ninomiya, Shigeo
    Bandoh, Toshio
    Arita, Tsuyoshi
    Kobayashi, Michio
    Okada, Fumito
    Mori, Hiromu
    JOURNAL OF BRONCHOLOGY & INTERVENTIONAL PULMONOLOGY, 2010, 17 (04) : 359 - 361
  • [47] The prevalence of circumportal pancreas as shown by multidetector-row computed tomography
    Kousei Ishigami
    Tsuyoshi Tajima
    Akihiro Nishie
    Yoshiki Asayama
    Daisuke Kakihara
    Tomohiro Nakayama
    Ken Shirabe
    Akinobu Taketomi
    Masafumi Nakamura
    Shunichi Takahata
    Tetsuhide Ito
    Hiroshi Honda
    Insights into Imaging, 2011, 2 (4) : 409 - 414
  • [48] Diagnostic accuracy of multidetector-row computed tomography for hilar cholangiocarcinoma
    Akamatsu, Nobuhisa
    Sugawara, Yasuhiko
    Osada, Hisato
    Okada, Takenori
    Itoyama, Shinji
    Komagome, Masahiko
    Shin, Nobuhiro
    Cho, Narihiro
    Ishida, Takashi
    Ozawa, Fumiaki
    Hashimoto, Daijo
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2010, 25 (04) : 731 - 737
  • [49] Coronary artery fistula: multidetector row computed tomography angiography in young child
    Hu, Xihong
    Huang, Guoying
    Pa, Mier
    CARDIOLOGY IN THE YOUNG, 2010, 20 (02) : 206 - 207
  • [50] Complications of myocardial infarction on multidetector-row computed tomography of chest
    Raj, V.
    Karunasaagarar, K.
    Rudd, J. H. F.
    Screaton, N.
    Gopalan, D.
    CLINICAL RADIOLOGY, 2010, 65 (11) : 930 - 936