Shaking table tests validating two strengthening interventions on masonry buildings

被引:0
|
作者
De Canio, Gerardo [1 ]
Muscolino, Giuseppe [2 ]
Palmeri, Alessandro [3 ]
Poggi, Massimo [1 ]
Clemente, Paolo [1 ]
机构
[1] ENEA, Res Ctr Casaccia, Rome, Italy
[2] Univ Messina, Dept Civil Engn, Messina, Italy
[3] Univ Bradford, Sch Engn Design & Technol, Bradford, W Yorkshire, England
关键词
timber-concrete composite; light slabs; shaking table test; FRP reinforcement;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Masonry buildings constitute quite often a precious cultural heritage for our cities. In order to future generations can enjoy this heritage, thence, effective projects of protection should be developed against all the anthropical and natural actions which may irreparably damage old masonry buildings. However, the strengthening interventions on these constructions have to respect their authenticity, without altering the original conception, not only functionally and aesthetically of course, but also statically. These issues are of central interests in the Messina area, where the seismic protection of new and existing constructions is a primary demand. It is well known, in fact, that the city of Messina lies in a highly seismic zone, and has been subjected to two destructive earthquakes in slightly more than one century, the 1783 Calabria earthquake and the more famous 1908 Messina-Reggio Calabria earthquake. It follows that the retrofitting projects on buildings which survived these two events should be designed with the aim to save the life of occupants operating with "light" techniques, i.e. respecting the original structural scheme. On the other hand, recent earthquakes, and in particular the 1997 Umbria-Marche sequence, unequivocally demonstrated that some of the most popular retrofitting interventions adopted in the second half the last century are absolutely ineffective, or even unsafe. Over these years, in fact, a number of "heavy" techniques proliferated, and therefore old masonry buildings suffered, among others, the substitution of existing timber slabs with more ponderous concrete slabs and/or the insertion of RC and steel members coupled with the original masonry elements (walls, arches, vaults). As a result, these buildings have been transformed by unwise engineers into hybrid structures, having a mixed behaviour (which frequently proved to be also unpredictable) between those of historic masonry and new members. Starting from these considerations, a numerical and experimental research has been carried out, aimed at validating two different strengthening interventions on masonry buildings: (i) the substitution of the existing roof with timber-concrete composite slabs, which are able to improve the dynamic behaviour of the structure without excessively increase die mass, and (ii) the reinforcement of masonry walls with FRP materials, which allow increasing both stiffness and strength of the construction. The experimental tests have been performed on a 1:2 scale model of a masonry building resembling a special type, the so-called "tipo misto messinese", which is proper to the reconstruction of the city of Messina after the 1783 Calabria earthquake. The model, incorporating a novel timber-concrete composite slab, has been tested on the main shaking table available at the ENEA Research Centre "Casaccia," both before and after the reinforcement with FRP materials. Some aspects related to the definition of the model and to the selection of an appropriate seismic input will be discussed, and numerical results confirming the effectiveness of the interventions mentioned above will be presented.
引用
收藏
页码:896 / +
页数:2
相关论文
共 50 条
  • [31] Shaking table tests of 1:3 scale confined masonry wall systems
    Alcocer, S.M.
    Muria-Vila, D.
    Informacion Tecnologica, 2000, 11 (05): : 113 - 122
  • [32] Seismic Behaviour of Confined Autoclaved Aerated Concrete Masonry Buildings: a Shaking Table Study
    Tomazevic, Miha
    Gams, Matija
    MAUERWERK, 2010, 14 (03) : 153 - 160
  • [33] Shaking table tests of two shallow reticulated shells
    Li, ZX
    Shen, ZY
    INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES, 2001, 38 (44-45) : 7875 - 7884
  • [34] Shaking table tests on the isolation performance of two buildings built on the top head of Shenyang metro depot
    Li L.
    Guo W.
    Jiang L.
    Wang C.
    Guo W.
    Jiao C.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2017, 36 (06): : 56 - 62and74
  • [35] In-Plane Strengthening Effect of Prefabricated Concrete Walls on Masonry Structures: Shaking Table Test
    Li, Weiwei
    Liu, Weiqing
    Wang, Shuguang
    Du, Dongsheng
    SHOCK AND VIBRATION, 2017, 2017
  • [36] A database of shake-table tests conducted on unreinforced masonry buildings
    Haindl, Mathias
    Smith, Ian F. C.
    Beyer, Katrin
    EARTHQUAKE SPECTRA, 2025, 41 (01) : 931 - 954
  • [37] STRENGTHENING OF UNREINFORCED MASONRY BUILDINGS
    PLECNIK, J
    COUSINS, T
    OCONNER, E
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1986, 112 (05): : 1070 - 1087
  • [38] Damage detection via modal analysis of masonry structures using shaking table tests
    Pepi, Chiara
    Cavalagli, Nicola
    Gusella, Vittorio
    Gioffre, Massimiliano
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2021, 50 (08): : 2077 - 2097
  • [39] Out-of-plane shaking table tests on unreinforced masonry panels in RC frames
    Tu, Yi-Hsuan
    Chuang, Tsung-Hua
    Liu, Pai-Mei
    Yang, Yuan-Sen
    ENGINEERING STRUCTURES, 2010, 32 (12) : 3925 - 3935
  • [40] Shaking table tests on dynamic response of coral sand foundation under buildings
    Ding X.-M.
    Wu Q.
    Liu H.-L.
    Chen Z.-X.
    Chen Y.-M.
    Peng Y.
    Yantu Gongcheng Xuebao/Chinese Journal of Geotechnical Engineering, 2019, 41 (08): : 1408 - 1417