EARTHING EFFECTIVE LENGTH FOR LOW AND HIGH AMPLITUDES OF LIGHTNING IMPULSE CURRENTS

被引:0
|
作者
Wojtas, Stanislaw [1 ]
机构
[1] Gdansk Univ Technol, Gdansk, Poland
关键词
Lightning protection earthing; earthing impulse impedance; effective length of earthing; test of earthings;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Earthings of the electrical power systems can achieve wide sizes. Due to equipotential bondings and a presence of main equipotential bar the earthing system can be connected even to a power transformer neutral point. Evaluation of such wide earthings for lightning protection purposes can not be easy to perform because only a part of the earthing system should be taken into account. This useful part of the earthing is described as its effective length. The paper deals with a method of effective length calculations and in order to explain the notion computer simulations and measurements of a model as well as a real earthing have been performed using impulses of 1, 4 and 10 mu s front times. A good convergence investigation results have been obtained.
引用
收藏
页码:137 / 141
页数:5
相关论文
共 50 条
  • [31] Field measurements on earthing systems of different soil resistivity values under high impulse conditions
    Abdullah, S.
    Nor, N. Mohamad
    Ramar, K.
    ELECTRICAL ENGINEERING, 2017, 99 (03) : 1005 - 1011
  • [32] Computation of Effective Length of Enhancement for Vertical Electrode Under Lightning Transients
    Kumar, Senthil A.
    Manickavasagam, Krishnan
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2022, 64 (06) : 2141 - 2148
  • [33] EARTHING AND BONDING IN HIGH-RISE BUILDINGS: PART 1. EARTHING OF LOW VOLTAGE INSTALLATIONS.
    Burnett, J.
    Hong Kong engineer, 1987, 15 (11): : 11 - 19
  • [34] Experimental and Analytical Studies of the Effects of Multiple Lightning Impulse Currents on Metal-Oxide Arrester Blocks
    Jiang, Anfeng
    Fu, Zhengcai
    Sun, Wei
    Chen, Jian
    Wang, Guoli
    Li, Ruihai
    2014 INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2014, : 681 - 687
  • [35] MEASUREMENT OF HIGH ENERGY PARTICLES IN A LIGHTNING IMPULSE VOLTAGE TEST IN AIR
    March, V.
    Montanya, J.
    Romero, D.
    2010 30TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP), 2010,
  • [36] International compatibility of reference measuring system for lightning impulse high voltage
    Miyazaki S.
    Goshima H.
    Wakimoto T.
    Ishii M.
    IEEJ Transactions on Power and Energy, 2021, 141 (08) : 547 - 550
  • [37] Analysis of conductive interference, on electronic equipment, due to low frequency currents flowing through the earthing installation
    Carrescia, M
    Molina, G
    IECEC 96 - PROCEEDINGS OF THE 31ST INTERSOCIETY ENERGY CONVERSION ENGINEERING CONFERENCE, VOLS 1-4, 1996, : 1823 - 1827
  • [38] Breakage of curved copper wires caused by high impulse current of lightning
    Hu, Xiaobo
    Inaba, Tsuginori
    Kindersberger, Josef
    IEEJ Transactions on Power and Energy, 2009, 129 (02) : 309 - 314
  • [39] Energy-based effective length of the: Impulse response of a recursive filter
    Laakso, TI
    Valimaki, V
    PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-6, 1998, : 1253 - 1256
  • [40] Energy-based effective length of the impulse response of a recursive filter
    Laakso, TI
    Välimäki, V
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (01) : 7 - 17