EARTHING EFFECTIVE LENGTH FOR LOW AND HIGH AMPLITUDES OF LIGHTNING IMPULSE CURRENTS

被引:0
|
作者
Wojtas, Stanislaw [1 ]
机构
[1] Gdansk Univ Technol, Gdansk, Poland
关键词
Lightning protection earthing; earthing impulse impedance; effective length of earthing; test of earthings;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Earthings of the electrical power systems can achieve wide sizes. Due to equipotential bondings and a presence of main equipotential bar the earthing system can be connected even to a power transformer neutral point. Evaluation of such wide earthings for lightning protection purposes can not be easy to perform because only a part of the earthing system should be taken into account. This useful part of the earthing is described as its effective length. The paper deals with a method of effective length calculations and in order to explain the notion computer simulations and measurements of a model as well as a real earthing have been performed using impulses of 1, 4 and 10 mu s front times. A good convergence investigation results have been obtained.
引用
收藏
页码:137 / 141
页数:5
相关论文
共 50 条
  • [11] OPTIMIZATION OF IMPULSE LENGTH AND AMPLITUDES OF IMPLANTABLE PACEMAKER (SM) SYSTEMS
    ALT, E
    WIRTZFELD, A
    PRAUER, H
    LAMPADIUS, M
    ZEITSCHRIFT FUR KARDIOLOGIE, 1982, 71 (09): : 629 - 629
  • [12] Design and Simulation of Impulse Current Circuit Based on the Standard Lightning Currents
    Chen Song
    Chen Yazhou
    CEEM: 2009 5TH ASIA-PACIFIC CONFERENCE ON ENVIRONMENTAL ELECTROMAGNETICS, 2009, : 250 - 253
  • [13] Extremely high lightning peak currents
    Birkl, Josef
    Diendorfer, Gerhard
    Kern, Alexander
    Thern, Stephan
    2018 34TH INTERNATIONAL CONFERENCE ON LIGHTNING PROTECTION (ICLP 2018), 2018,
  • [14] Fast and Effective Technique in Evaluation of Lightning Impulse Voltage Parameters
    Yutthagowith, Peerawut
    Kitwattana, Krit
    Kunakorn, Anantawat
    JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2021, 16 (01) : 459 - 467
  • [15] Fast and Effective Technique in Evaluation of Lightning Impulse Voltage Parameters
    Peerawut Yutthagowith
    Krit Kitwattana
    Anantawat Kunakorn
    Journal of Electrical Engineering & Technology, 2021, 16 : 459 - 467
  • [16] The effect of neutral earthing practices on lightning current dispersion in a low-voltage installation
    Mansoor, A
    Martzloff, F
    IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (03) : 783 - 792
  • [17] LOW-RESISTANCE SHUNTS FOR IMPULSE CURRENTS
    SCHWAB, AJ
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1971, PA90 (05): : 2251 - &
  • [18] Effective length of counterpoise wire under lightning current
    He, JL
    Gao, YQ
    Zeng, R
    Zou, J
    Liang, XD
    Zhang, B
    Lee, J
    Chang, S
    IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 1585 - 1591
  • [19] Lightning currents in low-voltage power systems
    Sowa, Andrzej
    PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (9B): : 275 - 277
  • [20] Measurements of grounding resistances for high impulse currents
    Sekioka, S
    Hayashida, H
    Hara, T
    Ametani, A
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1998, 145 (06) : 693 - 699