False positive aortic dissection on postmortem computed tomography

被引:3
|
作者
Le Blanc-Louvry, Isabelle [1 ]
Thureau, Sophie [1 ]
Ledoux, Kathy [1 ]
Mogdad, Benjamin [1 ]
Lagroy, Emma [1 ]
Dacher, Jean Nicolas [2 ]
Tournel, Gilles [1 ]
机构
[1] Univ Rouen, Hosp Charles Nicolle, Dept Forens Med, F-76031 Rouen, France
[2] Univ Rouen, Hosp Charles Nicolle, Dept Radiol, F-76031 Rouen, France
关键词
Forensic radiology; Postmortem computed tomography; Diagnostic error; Aortic dissection; CT; AUTOPSY; FEASIBILITY; ANGIOGRAPHY;
D O I
10.1016/j.forsciint.2015.06.014
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
Post-mortem CT-scan (PMCT) has become increasingly useful as a diagnostic tool. However, certain normal postmortem changes may mimic the appearance of pathologic findings. We report two cases of false positive aortic dissection. Methods: Non-contrast PMCT was performed on a sixty-four-detector row scanner. Each PMCT examination was assessed and reported by two independent radiologists. Autopsies were performed according European recommendations. Cases: In two corpses, a false positive DeBakey type I aortic dissection was detected. Autopsies confirmed that CT findings were artifactual. For each case the cause of the mistake was individually discussed and mainly based on the abnormalities observed during the autopsy. In fact, in our series (750 PMCT) a true aortic dissection was detected in two corpses during the same period. Conclusion: When a PMCT is performed, false positive aortic dissection can occur, which confirms the interest in combining opacification. (C) 2015 Published by Elsevier Ireland Ltd.
引用
收藏
页码:E4 / E6
页数:3
相关论文
共 50 条
  • [31] Shape filtering for false positive reduction at computed tomography colonography
    Miranda, Abhilash A.
    Chowdhury, Tarik A.
    Ghita, Ovidiu
    Whelan, Paul F.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2006, PT 2, 2006, 4191 : 84 - 92
  • [32] Marfan syndrome - aortic dissection type A, visualized by computed tomography
    Wojciuk, Jerzy
    Hoadley, Graham M.
    Brack, Michael J.
    VASCULAR MEDICINE, 2008, 13 (01) : 87 - 88
  • [33] Characterization of artifact simulating aortic dissection in computed tomography imaging
    Department of Radiological Sciences, Univ. of Oklahoma Health Sci. Ctr., PO Box 26901, Oklahoma City, OK 73190, United States
    J Digital Imaging, 1600, 2 SUPPL. 1 (220-221):
  • [34] Characterization of artifact simulating aortic dissection in computed tomography imaging
    Cindy K. Parry
    Balasubramanian Rajagopalan
    Journal of Digital Imaging, 2001, 14 : 220 - 221
  • [35] COMPUTED-TOMOGRAPHY OF THORACIC AORTIC DISSECTION - ACCURACY AND PITFALLS
    VASILE, N
    MATHIEU, D
    KEITA, K
    LELLOUCHE, D
    BLOCH, G
    CACHERA, JP
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (02) : 211 - 215
  • [36] Multi-detector computed tomography of an aortic dissection in a cat
    Scollan, Katherine
    Sisson, David
    JOURNAL OF VETERINARY CARDIOLOGY, 2014, 16 (01) : 67 - 72
  • [37] Pulmonary multislice computed tomography findings in acute aortic dissection
    Semiz-Oysu, Aslihan
    Okur, Aysegul
    Sahin, Sinan
    JOURNAL OF THORACIC DISEASE, 2012, 4 (05) : 485 - 489
  • [38] COMPUTED-TOMOGRAPHY VERSUS AORTOGRAPHY IN DIAGNOSIS OF AORTIC DISSECTION
    PARIENTY, RA
    COUFFINHAL, JC
    WELLERS, M
    FARGE, C
    PRADEL, J
    DOLOGA, M
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1982, 5 (06) : 285 - 291
  • [39] COMPUTED-TOMOGRAPHY IN PREOPERATIVE AND POSTOPERATIVE EVALUATION OF AORTIC DISSECTION
    LANDTMAN, M
    KIVISAARI, L
    STANDERTSKJOLDNORDENSTAM, CG
    TAAVITSAINEN, M
    ACTA RADIOLOGICA-DIAGNOSIS, 1986, 27 (03): : 273 - 278
  • [40] COMPUTED-TOMOGRAPHY AND ANGIOGRAPHY IN DISSECTING ANEURYSM (AORTIC DISSECTION)
    HERTER, M
    HARDER, T
    LEIPNER, N
    KRAHE, T
    ORELLANO, L
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1987, 147 (02): : 124 - 131