An artifact simulating aortic dissection has been seen in computed tomography (CT) and reported in numerous journals. The purpose of this study is to determine the origin. A phantom was constructed to simulate the motion of the ascending aorta during the cardiac cycle. Technique factors such as scan time, slice thickness, pitch, and reconstruction algorithms were examined for their effect on the simulated dissection appearance. Change in the angle of the simulated aorta with respect to the scanner axis was also studied. CT images displaying the simulated aortic dissection are obtained reproducibly. The amplitude of the artifact is more pronounced for increased scan time. The artifact amplitude is proportional to the displacement of the phantom. The simulated aortic dissection seems to be more pronounced when the scan time is comparable to the cycling time of aortic motion.
引用
收藏
页码:220 / 221
页数:1
相关论文
共 50 条
  • [1] Characterization of artifact simulating aortic dissection in computed tomography imaging
    Parry, CK
    Rajagopalan, B
    [J]. JOURNAL OF DIGITAL IMAGING, 2001, 14 (02) : 220 - 221
  • [2] MOTION ARTIFACT SIMULATING AORTIC DISSECTION
    POSNIAK, H
    OLSON, M
    DEMOS, T
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (02) : 420 - 420
  • [3] MOTION ARTIFACT SIMULATING AORTIC DISSECTION
    STANFORD, W
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (06) : 1408 - 1408
  • [4] Imaging of aortic dissection by helical computed tomography (CT)
    Serge Willoteaux
    Christophe Lions
    Virginia Gaxotte
    Ziad Negaiwi
    J. P. Beregi
    [J]. European Radiology, 2004, 14 : 1999 - 2008
  • [5] Updates on Computed Tomography Imaging in Aortic Aneurysms and Dissection
    Tanaka, Ryoichi
    Yoshioka, Kunihiro
    Abiko, Akihiko
    [J]. ANNALS OF VASCULAR DISEASES, 2020, 13 (01) : 23 - 27
  • [6] Imaging of aortic dissection by helical computed tomography (CT)
    Willoteaux, S
    Lions, C
    Gaxotte, V
    Negaiwi, Z
    Beregi, JP
    [J]. EUROPEAN RADIOLOGY, 2004, 14 (11) : 1999 - 2008
  • [7] MOTION ARTIFACT SIMULATING AORTIC DISSECTION ON CT
    BURNS, MA
    MOLINA, PL
    GUTIERREZ, FR
    SAGEL, SS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (03) : 465 - 467
  • [8] MOTION ARTIFACT SIMULATING AORTIC DISSECTION ON CT
    MUKHERJI, SK
    VARMA, P
    STARK, P
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (03) : 674 - 674
  • [9] SUPERIOR PERICARDIAL RECESS SIMULATING AORTIC DISSECTION ON COMPUTED-TOMOGRAPHY
    CHILES, C
    BAKER, ME
    SILVERMAN, PM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1986, 10 (03) : 421 - 423
  • [10] LEFT BRACHIOCEPHALIC VEIN SIMULATING AORTIC DISSECTION ON COMPUTED-TOMOGRAPHY
    TABER, P
    CHANG, LWM
    CAMPION, GM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (03) : 360 - 361