MOTION ARTIFACT SIMULATING AORTIC DISSECTION ON CT

被引:31
|
作者
BURNS, MA
MOLINA, PL
GUTIERREZ, FR
SAGEL, SS
机构
[1] Mallinckrodt Inst. of Radiol., Washington University, School of Medicine, St. Louis, MO 63110
关键词
D O I
10.2214/ajr.157.3.1872227
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We recently imaged two patients clinically suspected of having aortic dissection whose contrast-enhanced CT examinations, obtained on a new scanner with a 1-sec scanning time, showed findings suggesting an ascending aortic dissection. The subsequent clinical course and evaluation implied that the CT findings were predominantly artifactual. We identified identical artifacts in 18% of 50 consecutive contrast-enhanced CT examinations performed for a variety of indications on the same scanner. The double-lumen artifact, simulating an intimal flap, occurs in the proximal ascending aorta and is limited to one or two contiguous transaxial images. The artifact was not detected on two other CT units. We believe the artifact arises from motion of the aortic wall and the surrounding pericardial recesses during image acquisition.
引用
收藏
页码:465 / 467
页数:3
相关论文
共 50 条
  • [1] MOTION ARTIFACT SIMULATING AORTIC DISSECTION ON CT
    MUKHERJI, SK
    VARMA, P
    STARK, P
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (03) : 674 - 674
  • [2] MOTION ARTIFACT SIMULATING AORTIC DISSECTION
    STANFORD, W
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 158 (06) : 1408 - 1408
  • [3] MOTION ARTIFACT SIMULATING AORTIC DISSECTION
    POSNIAK, H
    OLSON, M
    DEMOS, T
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (02) : 420 - 420
  • [4] AORTIC MOTION ARTIFACT SIMULATING DISSECTION ON CT SCANS - ELIMINATION WITH RECONSTRUCTIVE SEGMENTED IMAGES
    POSNIAK, HV
    OLSON, MC
    DEMOS, TC
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 161 (03) : 557 - 558
  • [5] Motion artifacts of the aorta simulating aortic dissection on spiral CT
    Qanadli, SD
    El Hajjam, M
    Mesurolle, B
    Lavisse, L
    Jourdan, O
    Randoux, B
    Chagnon, S
    Lacombe, P
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (01) : 1 - 6
  • [6] Prevalence of motion artifact simulating aortic dissection on spiral CT using a 180 ° linear interpolation algorithm for reconstruction of the images
    P. Loubeyre
    F. Grozel
    Y. Carrillon
    C. Gaillard
    F. Guyard
    O. Pellet
    V. A. Tran Minh
    [J]. European Radiology, 1997, 7 : 320 - 322
  • [7] Motion Artifact Resulting in a False Positive CT Angiogram for a Presumed Aortic Dissection
    Karras, Riny
    Ricci, Marco
    Salerno, Thomas A.
    Gologorsky, Edward
    [J]. JOURNAL OF CARDIAC SURGERY, 2011, 26 (02) : 223 - 224
  • [8] Prevalence of motion artifact simulating aortic dissection on spiral CT using a 180 degrees linear interpolation algorithm for reconstruction of the images
    Loubeyre, P
    Grozel, F
    Carrillon, Y
    Galliard, C
    Pellet, O
    Minh, VAT
    [J]. EUROPEAN RADIOLOGY, 1997, 7 (03) : 320 - 322
  • [9] Characterization of artifact simulating aortic dissection in computed tomography imaging
    Cindy K. Parry
    Balasubramanian Rajagopalan
    [J]. Journal of Digital Imaging, 2001, 14 : 220 - 221
  • [10] Characterization of artifact simulating aortic dissection in computed tomography imaging
    Parry, CK
    Rajagopalan, B
    [J]. JOURNAL OF DIGITAL IMAGING, 2001, 14 (02) : 220 - 221