Retrofitting of vulnerable RC structures by base isolation technique

被引:0
|
作者
Islam, A. B. M. Saiful [1 ]
Jumaat, Mohd Zamin [1 ]
Ahmmad, Rasel [1 ]
Darain, Kh. Mahfuz Ud [1 ,2 ]
机构
[1] Univ Malaya, Dept Civil Engn, Kuala Lumpur, Malaysia
[2] Khulna Univ, Architecture Discipline, Khulna, Bangladesh
关键词
aseismic building; base isolation; nonlinear dynamics; linear dynamic analysis; seismic excitation; structural insinuation; economic insinuation; ISOLATED HIGHRISE BUILDINGS; STEEL BEARING ISOLATION; ISOLATION SYSTEM; FAULT EARTHQUAKES; SEISMIC RESPONSE; MODEL; TIME; IDENTIFICATION; BEHAVIOR; MOTIONS;
D O I
暂无
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The scale and nature of the recent earthquakes in the world and the related earthquake disaster index coerce the concerned community to become anxious about it. Therefore, it is crucial that seismic lateral load effect will be appropriately considered in structural design. Application of seismic isolation system stands as a consistent alternative against this hazard. The objective of the study is to evaluate the structural and economic feasibility of reinforced concrete (RC) buildings with base isolation located in medium risk seismic region. Linear and nonlinear dynamic analyses as well as linear static analysis under site-specific bi-directional seismic excitation have been carried out for both fixed based (FB) and base isolated (BI) buildings in the present study. The superstructure and base of buildings are modeled in a 3D finite element model by consistent mass approach having six degrees of freedom at each node. The floor slabs are simulated as rigid diaphragms. Lead rubber bearing (LRB) and High damping rubber bearing (HDRB) are used as isolation device. Change of structural behaviors and savings in construction costing are evaluated. The study shows that for low to medium rise buildings, isolators can reduce muscular amount of base shears, base moments and floor accelerations for building at soft to medium stiff soil. Allowable higher horizontal displacement induces structural flexibility. Though incorporating isolator increases the outlay, overall structural cost may be reduced. The application of base isolation system confirms a potential to be used as a viable solution in economic building design.
引用
收藏
页码:603 / 623
页数:21
相关论文
共 50 条
  • [31] Seismic Isolation: An Effective Technique for the Seismic Retrofitting of a Reinforced Concrete Building
    Giarlelis, Christos
    Koufalis, Dimitrios
    Repapis, Constantinos
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2020, 30 (01) : 43 - 52
  • [32] Base Isolation for Seismic Retrofitting of a Multiple Building Structure: Design, Construction, and Assessment
    Ferraioli, Massimiliano
    Mandara, Alberto
    [J]. MATHEMATICAL PROBLEMS IN ENGINEERING, 2017, 2017
  • [33] BASE ISOLATION SYSTEMS IN BUILDING STRUCTURES
    Golebiowska, I.
    Sakiewicz, W.
    [J]. ENGINEERING MECHANICS 2014, 2014, : 192 - 195
  • [34] Hybrid strategy for the seismic retrofitting of existing buildings through Base Isolation System
    Giuseppe, Brandonisio
    Guidi, Laura Giovanna
    Camarda, Guido
    Sorrentino, Paola
    De Luca, Antonello
    [J]. XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 1292 - 1299
  • [35] PROBABILISTIC OPTIMUM BASE ISOLATION OF STRUCTURES
    CONSTANTINOU, MC
    TADJBAKHSH, IG
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1983, 109 (03): : 676 - 689
  • [36] Base isolation for segmental building structures
    Charng, PH
    Carr, AJ
    Moss, PJ
    [J]. MECHANICS OF STRUCTURES AND MATERIALS, 1997, : 363 - 368
  • [37] SEISMIC BASE ISOLATION FOR STEEL STRUCTURES
    STIEMER, SF
    BARWIG, BB
    [J]. CANADIAN JOURNAL OF CIVIL ENGINEERING, 1985, 12 (01) : 73 - 81
  • [38] Development of fragility curves for base isolated RC structures
    Bakhshi, A.
    Mostafavi, S. A.
    [J]. EURODYN 2014: IX INTERNATIONAL CONFERENCE ON STRUCTURAL DYNAMICS, 2014, : 2947 - 2953
  • [39] Artificial neural network for technical feasibility prediction of seismic retrofitting in existing RC structures
    Falcone, Roberto
    Ciaramella, Angelo
    Carrabs, Francesco
    Strisciuglio, Nicola
    Martinelli, Enzo
    [J]. STRUCTURES, 2022, 41 : 1220 - 1234
  • [40] Effectiveness of base isolation system for simple RC frame buildings
    Kilar, V.
    Koren, D.
    [J]. INNOVATIONS IN STRUCTURAL ENGINEERING AND CONSTRUCTION, VOLS 1 AND 2, 2008, : 969 - 975