Correction for hole trapping in AGATA detectors using pulse shape analysis

被引:14
|
作者
Bruyneel, B. [1 ,2 ]
Birkenbach, B. [2 ]
Eberth, J. [2 ]
Hess, H. [2 ]
Pascovici, Gh. [2 ]
Reiter, P. [2 ]
Wiens, A. [2 ]
Bazzacco, D. [3 ]
Farnea, E. [3 ]
Michelagnoli, C. [3 ]
Recchia, F. [3 ]
机构
[1] CEA Saclay, DSM IRFU SPhN, F-91191 Gif Sur Yvette, France
[2] Univ Cologne, Inst Kernphys, Cologne, Germany
[3] Ist Nazl Fis Nucl, Sez Padova, Padua, Italy
来源
EUROPEAN PHYSICAL JOURNAL A | 2013年 / 49卷 / 05期
关键词
HPGE-DETECTORS; NEUTRON DAMAGE; GERMANIUM; RESOLUTION; CAPTURE; ARRAY;
D O I
10.1140/epja/i2013-13061-4
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
Data from the highly segmented High-Purity Germanium (HPGe) detectors of the AGATA spectrometer show that segments are more sensitive to neutron damage than the central core contact. Calculations on the collection efficiency of charge carriers inside the HPGe detector were performed in order to understand this phenomenon. The trapping sensitivity, an expression based on the collection efficiencies for electrons and holes, is put forward to quantify the effect of charge carrier trapping. The sensitivity is evaluated for each position in the detector volume with respect to the different electrodes and the collected charge carrier type. Using the position information obtained by pulse shape analysis from the position-sensitive AGATA detectors, it is possible to correct for the energy deficit employing detector specific sensitivity values. We report on the successful correction of the energy peaks from heavily neutron-damaged AGATA detectors for core and segment electrode signals. The original energy resolution can optimally be recovered up to a certain quantifiable limit of degradation due to statistical fluctuations caused by trapping effects.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [41] Pulse shape analysis for γ-ray tracking (Part II): Fully informed particle swarm algorithm applied to AGATA
    Schlarb, M.
    Gernhaeuser, R.
    Klupp, S.
    Kruecken, R.
    [J]. EUROPEAN PHYSICAL JOURNAL A, 2011, 47 (10):
  • [42] Pulse shape analysis for γ-ray tracking (Part II): Fully informed particle swarm algorithm applied to AGATA
    M. Schlarb
    R. Gernhäuser
    S. Klupp
    R. Krücken
    [J]. The European Physical Journal A, 2011, 47
  • [43] CdZnTe drift detector with correction for hole trapping
    van Pamelen, MAJ
    Budtz-Jorgensen, C
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 411 (01): : 197 - 200
  • [44] Trapping and detrapping effects in high-quality chemical-vapor-deposition diamond films: Pulse shape analysis of diamond particle detectors
    Marinelli, M
    Milani, E
    Paoletti, A
    Tucciarone, A
    Verona-Rinati, G
    Angelone, M
    Pillon, M
    [J]. PHYSICAL REVIEW B, 2001, 64 (19)
  • [45] PULSE SHAPE DISCRIMINATION WITH SOLID STATE DETECTORS
    SCHEER, JA
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1963, 22 (01): : 45 - 47
  • [46] HOLE TRAPPING LEVELS IN NATURAL DIAMOND NUCLEAR-DETECTORS
    DEBLASI, C
    GALASSINI, S
    MICOCCI, G
    RUGGIERO, L
    TEPORE, A
    NAVA, F
    MANFREDOTTI, C
    KOZLOV, SF
    [J]. NUCLEAR INSTRUMENTS & METHODS, 1979, 163 (01): : 121 - 124
  • [47] Pulse shape simulations for organic scintillation detectors using Geant4
    Holroyd, Caroline
    Aspinall, Michael
    Deakin, Tom
    [J]. ANIMMA 2021 - ADVANCEMENTS IN NUCLEAR INSTRUMENTATION MEASUREMENT METHODS AND THEIR APPLICATIONS, 2021, 253
  • [48] Principal Component Analysis for pulse-shape discrimination of scintillation radiation detectors
    Alharbi, T.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 806 : 240 - 243
  • [49] Pulse shape analysis for segmented germanium detectors implemented in graphics processing units
    Calore, Enrico
    Bazzacco, Dino
    Recchia, Francesco
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2013, 719 : 1 - 5
  • [50] Pulse-shape analysis for gamma background rejection in thermal neutron radiation using CVD diamond detectors
    Kavrigin, P.
    Finocchiaro, P.
    Griesmayer, E.
    Jericha, E.
    Pappalardo, A.
    Weiss, C.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2015, 795 : 88 - 91