摘要
Data from the highly segmented High-Purity Germanium (HPGe) detectors of the AGATA spectrometer show that segments are more sensitive to neutron damage than the central core contact. Calculations on the collection efficiency of charge carriers inside the HPGe detector were performed in order to understand this phenomenon. The trapping sensitivity, an expression based on the collection efficiencies for electrons and holes, is put forward to quantify the effect of charge carrier trapping. The sensitivity is evaluated for each position in the detector volume with respect to the different electrodes and the collected charge carrier type. Using the position information obtained by pulse shape analysis from the position-sensitive AGATA detectors, it is possible to correct for the energy deficit employing detector specific sensitivity values. We report on the successful correction of the energy peaks from heavily neutron-damaged AGATA detectors for core and segment electrode signals. The original energy resolution can optimally be recovered up to a certain quantifiable limit of degradation due to statistical fluctuations caused by trapping effects.
引用
收藏
页码:1 / 9
页数:9
相关论文
共 50 条
  • [31] PULSE SHAPE ANALYZER FOR PHOSWICH DETECTORS
    SHOFFNER, BM
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1972, NS19 (01) : 502 - &
  • [32] Simulations using the pulse shape comparison scanning technique on an AGATA segmented HPGe gamma-ray detector
    De Canditiis B.
    Duchêne G.
    [J]. European Physical Journal A, 2020, 56 (10):
  • [33] Characterization of Segmented HPGe Detectors Using Pulse Shape Comparison Methods
    Crespi, F. C. L.
    Vandone, V.
    Camera, F.
    Brambilla, S.
    Million, B.
    Riboldi, S.
    Wieland, O.
    Boston, A. J.
    Unsworth, C.
    Boston, H. C.
    Colosimo, S. J.
    Moon, S.
    Nolan, P. J.
    [J]. 2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 825 - 827
  • [34] PULSE-SHAPE ANALYSIS FOR GERMANIUM DETECTORS USED IN DM SEARCHES
    SAGDEEV, IR
    DRUKIER, AK
    WELSH, DJ
    KLIMENKO, AA
    OSETROV, SB
    SMOLNIKOV, AA
    [J]. NUCLEAR PHYSICS B, 1994, : 175 - 179
  • [35] Pulse shape simulation and analysis of segmented Ge detectors for position extraction
    Kurokawa, M
    Shimoura, S
    Iwasaki, H
    Baba, H
    Michimasa, SI
    Ota, S
    Murakami, H
    Sakai, H
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1309 - 1316
  • [36] Modelling of diamond detectors: effects of the polycrystalline structure and a pulse shape analysis
    Milazzo, L
    Mainwood, A
    [J]. DIAMOND AND RELATED MATERIALS, 2004, 13 (4-8) : 934 - 937
  • [37] Particles identification by means of digital pulse shape analysis in silicon detectors
    Duenas, J. A.
    Martel, I.
    [J]. LA RABIDA 2012 INTERNATIONAL SCIENTIFIC MEETING ON NUCLEAR PHYSICS: BASIC CONCEPTS IN NUCLEAR PHYSICS: THEORY, EXPERIMENTS, AND APPLICATIONS, 2013, 1541 : 144 - 145
  • [38] Efficiency of segmented HPGe detectors: Design criteria for pulse shape analysis
    Wieland, O
    Camera, F
    Million, B
    Bracco, A
    Pignanelli, M
    Ripamonti, G
    Geraci, A
    Van der Marel, J
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (03) : 296 - 301
  • [39] Pulse shape simulation and analysis of segmented Ge detectors for position extraction
    Kurokawa, M
    Shimoura, S
    Iwasaki, H
    Baba, H
    Michimasa, S
    Ota, S
    Murakami, H
    Sakai, H
    [J]. 2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 369 - 374
  • [40] Improvements through pulse shape analysis in x-ray spectrometry using Si(Li) detectors
    Homman, NPO
    Kristiansson, P
    [J]. X-RAY SPECTROMETRY, 1996, 25 (02) : 66 - 73