Wavelet-based event detection in implantable cardiac rhythm management devices

被引:12
|
作者
Åström, M
Olmos, S
Sörnmo, L
机构
[1] Lund Univ, Dept Elect Engn, SE-22100 Lund, Sweden
[2] Univ Zaragoza, Dept Elect Engn & Commun, Zaragoza 50009, Spain
关键词
electrogram; event detection; implantable cardiac devices; pacemakers; wavelets;
D O I
10.1109/TBME.2005.869775
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This paper presents a novel event detector for implantable devices. The algorithm is based on a signal model which describes an event as a linear combination of basis functions. The linear combination involves two fundamental electrogram waveforms represented at different time scales. An efficient, low-complexity detector is developed using the dyadic wavelet transform with integer filter coefficients, and a generalized likelihood ratio test. The results show that reliable detection is obtained at an intermediate signal-to-noise ratio (SNR = 25 dB) for various common noise sources. In terms of probabilities of missed events and false alarms, an over-all performance of 0.7% and 0.1%, respectively, was achieved on electrograms corrupted by the different noise types at an intermediate SNR.
引用
收藏
页码:478 / 484
页数:7
相关论文
共 50 条
  • [31] Wavelet-based Burst Event Detection and Localization in Water Distribution Systems
    Seshan Srirangarajan
    Michael Allen
    Ami Preis
    Mudasser Iqbal
    Hock Beng Lim
    Andrew J. Whittle
    Journal of Signal Processing Systems, 2013, 72 : 1 - 16
  • [32] Impact of ESRD on Infections of Implantable Cardiac Rhythm Devices
    Ipek, Esra Gucuk
    Guray, Yesim
    Guray, Umit
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2015, 65 (01) : 169 - 169
  • [33] The Analog Blanking Period of Implantable Cardiac Rhythm Devices
    Barold, S. Serge
    Kucher, Andreas
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (02): : 115 - 127
  • [34] THE BILITCH REPORT .B. PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    SONG, SL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (07): : 1485 - 1487
  • [35] THE BILITCH REPORT .B. PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    SONG, SL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (04): : 823 - 827
  • [36] WAVELET-BASED CORNER DETECTION
    LEE, JS
    SUN, YN
    CHEN, CH
    TSAI, CT
    PATTERN RECOGNITION, 1993, 26 (06) : 853 - 865
  • [37] Detection of cardiac tachyarrhythmias in implantable devices
    Gillberg, Jeffrey
    JOURNAL OF ELECTROCARDIOLOGY, 2007, 40 (06) : S123 - S128
  • [38] MANAGEMENT OF INFECTED IMPLANTABLE CARDIAC DEVICES
    Bernard, K.
    Branscombe, P.
    Harper, H.
    Martin, P.
    Methot, M.
    CANADIAN JOURNAL OF CARDIOLOGY, 2010, 26 : 164D - 164D
  • [39] Infections of implantable cardiac rhythm devices: predisposing factors and outcome
    Ipek, Esra Gucuk
    Guray, Umit
    Demirkan, Burcu
    Guray, Yesim
    Aksu, Tolga
    ACTA CARDIOLOGICA, 2012, 67 (03) : 303 - 310
  • [40] Atrial fibrillation variability on long-term monitoring of implantable cardiac rhythm management devices
    Kaplan, Rachel M.
    Ziegler, Paul D.
    Koehler, Jodi
    Glotzer, Taya V.
    Passman, Rod S.
    CLINICAL CARDIOLOGY, 2017, 40 (11) : 1044 - 1048