Infections of implantable cardiac rhythm devices: predisposing factors and outcome

被引:27
|
作者
Ipek, Esra Gucuk [1 ]
Guray, Umit [1 ]
Demirkan, Burcu [1 ]
Guray, Yesim [1 ]
Aksu, Tolga [1 ]
机构
[1] Yuksek Ihtisas Hosp, Cardiol Clin, Ankara, Turkey
关键词
Implantable cardiac rhythm devices; pacemaker infections; device-related endocarditis; CARDIOVERTER-DEFIBRILLATOR INFECTION; PERMANENT PACEMAKER; LEAD ENDOCARDITIS; RISK-FACTORS; MANAGEMENT; VEGETATIONS; EXTRACTION; REMOVAL; FEATURES; TRENDS;
D O I
10.2143/AC.67.3.2160719
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objective Infection is a serious complication of cardiac devices. We aimed to describe predisposing factors and outcome of permanent pacemaker (PPM) and implantable cardioverter/defibrillator (ICD) infections. Method We reviewed cardiac device infections diagnosed at the Yuksek Ihtisas Hospital Ankara, Turkey, between 2004 and 2010 retrospectively. Demographic and clinical data were collected, descriptive analysis was performed. Results From 2004 to 2010, a total of 1916 devices were implanted. Thirty-four cases of confirmed device infections were identified giving an infection rate of 1.7%. Seventy-three percent of the cases were men. Mean age was 58 +/- 19 years. Twenty-two patients had a PPM, 12 had an ICD or cardiac resynchronization therapy (CRT). Diabetes mellitus, hypertension, cardiac failure, anaemia and immune suppression were prominent comorbidities. Previously, 6 (17%) patients had a history of replacement, 6 (17%) had revision, 3(8%) had haematoma. Ten (29%) patients reported a history of long hospital stay and 13(38%) patients had multiple hospitalizations. Pocket infection (70%) was the most common clinical presentation. Ninety-one percent of patients were cured with both device removal and antibiotic administration. Complications of cardiac device infections included septic emboli, acute renal failure, inotropic infusion requirement which were mostly seen among patients with endocarditis. Five patients suffered relapsing infection. Three patients died, among them two had infective endocarditis. Conclusion Cardiac device infections have been encountered more often in recent years. Cure of device infections is achievable in a majority of patients treated with antimicrobial treatment and complete device removal although device-related endocarditis can have an aggressive course.
引用
收藏
页码:303 / 310
页数:8
相关论文
共 50 条
  • [1] Impact of ESRD on Infections of Implantable Cardiac Rhythm Devices
    Ipek, Esra Gucuk
    Guray, Yesim
    Guray, Umit
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2015, 65 (01) : 169 - 169
  • [2] Two Implantable Devices for Cardiac Rhythm Management
    Tang, Jonathan E.
    Ryu, Jasmine N.
    Essandoh, Michael K.
    Savona, Salvatore J.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (02) : 326 - 329
  • [3] Future of Implantable Devices for Cardiac Rhythm Management
    Lau, Chu-Pak
    Siu, Chung-Wah
    Tse, Hung-Fat
    CIRCULATION, 2014, 129 (07) : 811 - 822
  • [4] Infections of cardiac implantable electrical devices
    Billick, Maxime J.
    Bogler, Orly
    Gold, Wayne L.
    CANADIAN MEDICAL ASSOCIATION JOURNAL, 2024, 196 (12) : E415 - E415
  • [5] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    SONG, SL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (04): : 475 - 486
  • [6] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    BILITCH, M
    HAUSER, RG
    GOLDMAN, BS
    MALONEY, JD
    HARTHORNE, JW
    FURMAN, S
    PARSONNET, V
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (02): : 389 - 398
  • [7] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    FURMAN, S
    GROSS, J
    FRAME, R
    JOHNSTON, D
    PARSONNET, V
    ROTHBART, ST
    ZIMMERMAN, J
    KAWANISHI, DT
    SONG, SL
    HASHIMOTO, KK
    BUCKINGHAM, TA
    GOLDIN, MD
    DENKER, ST
    LIPTON, IH
    CASTLE, LW
    SHEWCHIK, JM
    HARTHORNE, JW
    RUSKIN, JN
    GARAN, H
    MCGOVERN, BA
    GRIFFIN, JC
    SCHEINMAN, MM
    LESH, MD
    DORIAN, P
    NEWMAN, D
    DENES, P
    DAHL, W
    SAKSENA, S
    KROL, RB
    FOGOROS, RN
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1994, 17 (01): : 131 - 133
  • [8] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    SONG, SL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (10): : 1559 - 1561
  • [9] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    SONG, SL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1991, 14 (04): : 589 - 602
  • [10] PERFORMANCE OF IMPLANTABLE CARDIAC-RHYTHM MANAGEMENT DEVICES
    SONG, SL
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1992, 15 (01): : 120 - 121