An ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of obeticholic acid in rat plasma and its application in preclinical pharmacokinetic studies

被引:6
|
作者
Li, Xiang-yu [1 ]
Zhu, Sheng-hong [2 ]
Yang, Fang [1 ]
Hu, Guo-xin [3 ]
Yuan, Ling-jing [4 ]
机构
[1] Shaoxing Keqiao Women & Childrens Hosp, Dept Pharm, Shaoxing, Zhejiang, Peoples R China
[2] Shaoxing Keqiao Women & Childrens Hosp, Dept Sci Educ, Shaoxing, Zhejiang, Peoples R China
[3] Wenzhou Med Univ, Dept Pharmacol, Sch Pharm, Wenzhou, Zhejiang, Peoples R China
[4] Shaoxing Second Hosp, Dept Pharm, Shaoxing, Zhejiang, Peoples R China
关键词
Obeticholic acid; Ultra-performance liquid chromatography-tandem mass spectrometry; Rat plasma; Pharmacokinetics; PRIMARY BILIARY-CIRRHOSIS; FARNESOID-X RECEPTOR; BIOCHEMICAL RESPONSE; NUCLEAR RECEPTOR; FXR;
D O I
10.1016/j.jchromb.2019.05.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Currently, ursodeoxycholic acid (UDCA) is the only clear medical treatment for primary biliary cholangitis (PBC). However, approximately 40% of patients are not sensitive to UDCA. In recent years, obeticholic acid (OCA) combined with UDCA has been used in the PBC patients who were not sensitive to UDCA, or as mono-therapy for PBC adult patients who are intolerant to UDCA. Objective: To develop and validate a specific, sensitive and reliable tandem mass spectrometry (UPLC-MS/MS) method for the determination of obeticholic acid (OCA) in rat plasma. Methods: Plasma samples were treated with liquid-liquid extraction. Diazepam was selected as the internal standard (IS). Chromatographic separation was achieved by an Acquity BEH C18 column (2.1 mm x 50 mm, 1.7 mu m) and a mobile phase consisting of acetonitrile and ultrapure water (containing 0.1% formic acid). The analyte was detected in positive ion mode by electrospray ionization mass spectrometry (ESI-MS). Multiple reaction monitoring (MRM) methods were used to detect specific precursor and product ions. The target ion pair of OCA was 419.38 -> 401.22, and the IS was 285.05 -> 193.02. Results: The linear range of OCA in rat plasma was 0.05-50 mu g/mL (R-2 = 0.992); the recovery rate was 91.34%-97.37%. This assay showed good intra- and inter-day precision and accuracy. No significant matrix effects in this study. Conclusion: A specific, sensitive and reliable quantitative analysis method was established to detect OCA after oral/intravenous administration in rat plasma via UPLC-MS/MS. It was appropriate for preclinical pharmacokinetic studies of OCA.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [11] Determination of eugenitin in mouse blood by ultra-performance liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study
    Lin, Chongliang
    Song, Dezhen
    Jiang, Haodong
    Luo, Lvqi
    Bao, Xi
    Yu, Xiaomin
    Ma, Jianshe
    Wang, Xianqin
    Jiang, Xiajuan
    ACTA CHROMATOGRAPHICA, 2022, 34 (03) : 253 - 257
  • [12] Simultaneous determination of ambroxol and salbutamol in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study
    Guo, Zhening
    Chen, Yangsheng
    Ding, Xiaoliang
    Huang, Chenrong
    Miao, Liyan
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (11) : 1789 - 1795
  • [13] An Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS) Method for Qualifying DAPB in Rat Plasma and Application to Pharmacokinetic Studies
    Qin, Bei
    Chen, Yunmei
    Yang, Kuan
    Wang, Rong
    Yu, Lili
    Wang, Nana
    Liu, Shaojing
    MOLECULES, 2024, 29 (02):
  • [14] Validation of an ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of flecainide in human plasma and its clinical application
    Mano, Yuji
    Asakawa, Yoshiki
    Kita, Kenji
    Ishii, Takuho
    Hotta, Koichiro
    Kusano, Kazutomi
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (09) : 1399 - 1405
  • [15] Determination of artemisitene in rat plasma by ultra-performance liquid chromatography/tandem mass spectrometry and its application in pharmacokinetics
    Wu, Li-lan
    Wu, Yun-Shan
    Chen, Wei-Ying
    Zhou, Wen
    Tang, Lipeng
    Li, Ben
    Liu, Bo
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (13) : 1121 - 1128
  • [16] Determination of Ferulic Acid in Rat Plasma by Liquid Chromatography-Tandem Mass Spectrometry Method: Application to a Pharmacokinetic Study
    Zhang, Tianhong
    Yang, Xiuli
    Zhang, Peng
    Zhu, Meng
    He, Zhonggui
    Bi, Kaishun
    ANALYTICAL LETTERS, 2009, 42 (14) : 2157 - 2169
  • [17] Determination of fascaplysin in rat plasma with ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS): application to a pharmacokinetic study
    Hu, Zhiyan
    Zhang, Manman
    He, Ming
    Fang, Bingqing
    Bao, Xiujie
    Yan, Xiaojun
    Liang, Hongze
    Wang, Haixing
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 171 : 126 - 131
  • [18] Determination of Tenacissoside A in rat plasma by liquid chromatography-tandem mass spectrometry method and its application to pharmacokinetic study
    Zhao, Luhua
    Xiang, Bingren
    Chen, Jing
    Tan, Xiying
    Wang, Dawei
    Chen, Daofeng
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2009, 877 (20-21): : 1799 - 1804
  • [19] Determination and Pharmacokinetic Study of Chiisanogenin in Rat Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Yang, Chunjuan
    Yu, Kai
    Song, Yang
    Qin, Feng
    Li, Famei
    PHYTOCHEMICAL ANALYSIS, 2011, 22 (03) : 225 - 229
  • [20] Pharmacokinetic studies of novel berberine derivatives with ultra-performance liquid chromatography-tandem mass spectrometry
    Wang, Wenchao
    Shen, Qin
    Liang, Hui
    Hua, Changlong
    Liu, Yuhui
    Li, Fengzhi
    Li, Qingyong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1031 : 172 - 180