Validation of an ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of flecainide in human plasma and its clinical application

被引:5
|
作者
Mano, Yuji [1 ]
Asakawa, Yoshiki [2 ]
Kita, Kenji [2 ]
Ishii, Takuho [2 ]
Hotta, Koichiro [1 ]
Kusano, Kazutomi [1 ]
机构
[1] Eisai & Co Ltd, Biopharmaceut Assessment Core Funct Unit, Drug Metab & Pharmacokinet, Tsukuba, Ibaraki 3002635, Japan
[2] Sunplanet Co Ltd, Tsukuba Div, Anal Grp, Tsukuba, Ibaraki 3002635, Japan
关键词
UPLC-MS; MS; flecainide; validation; ISR; hemolysis; SUPRAVENTRICULAR TACHYCARDIA; SERUM FLECAINIDE; CHILDREN; THERAPY;
D O I
10.1002/bmc.3437
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and reproducible bioanalytical method for the determination of flecainide in human plasma was developed and validated using an ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) to obtain higher sensitivity than the current available methods. After simple protein precipitation, flecainide and a stable isotope-labeled internal standard (IS) were chromatographed on an Acquity UPLC BEH C-18 column (2.1 x 100 mm, 1.7 mu m) with isocratic elution of mobile phase consisting of 45% methanol containing 0.1% formic acid at a flow rate 0.25 mL/min. Detection was performed in positive electrospray ionization by monitoring the selected ion transitions at m/z 415.4/301.1 for flecainide and m/z 419.4/305.1 for the IS. The method was validated according to current bioanalytical method validation guidelines. The calibration standard curve was linear from 2.5 to 1000 ng/mL using 0.1 mL of plasma. No significant interferences were detected in blank human plasma. Accuracy and precision in the intra- and inter-batch reproducibility study were within acceptance criteria. Neither hemolysis effects nor matrix effects were observed. The UPLC-MS/MS method developed was successfully applied to determine plasma flecainide concentrations to support clinical studies and incurred sample reanalysis also ensured the reproducibility of the method. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:1399 / 1405
页数:7
相关论文
共 50 条
  • [1] New ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of irbesartan in human plasma
    Wani, Tanveer A.
    Zargar, Seema
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2015, 23 (03) : 569 - 576
  • [2] Ultra-performance liquid chromatography-tandem mass spectrometry for the determination of lacidipine in human plasma and its application in a pharmacokinetic study
    Tang, Jing
    Zhu, Ronghua
    Zhao, Ruike
    Cheng, Gang
    Peng, Wenxing
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (4-5) : 923 - 928
  • [3] Validation of a hydrophilic interaction ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of gemcitabine in human plasma with tetrahydrouridine
    Mano, Yuji
    Sakamaki, Kenji
    Ueno, Takuya
    Kita, Kenji
    Ishii, Takuho
    Hotta, Koichiro
    Kusano, Kazutomi
    BIOMEDICAL CHROMATOGRAPHY, 2015, 29 (09) : 1343 - 1349
  • [4] Development and validation of an ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of baloxavir in rat plasma and its application to pharmacokinetic studies
    Mu, Hongli
    Zhang, Wenyu
    Song, Yuanming
    Liang, Rui
    Zhao, Hengli
    Song, Chunhong
    Wen, Qing
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (11)
  • [5] Development and validation of an ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of baloxavir in rat plasma and its application to pharmacokinetic studies
    Mu, Hongli
    Zhang, Wenyu
    Song, Yuanming
    Liang, Rui
    Zhao, Hengli
    Song, Chunhong
    Wen, Qing
    BIOMEDICAL CHROMATOGRAPHY, 2023,
  • [6] Determination of phenylephrine in human plasma using ultra-performance liquid chromatography-tandem mass spectrometry
    Feng, Sheng
    Zhao, Qian
    Jiang, Ji
    Hu, Pei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 915 : 28 - 32
  • [7] Determination of simvastatin in human plasma using ultra-performance liquid chromatography-tandem mass spectrometry
    Wang Dong
    Qin Feng
    Chen Lingyun
    Hao Yu
    Zhang Yi
    Li Famei
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2008, 26 (03) : 327 - 330
  • [8] Ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of febuxostat in dog plasma and its application to a pharmacokinetic study
    Zhang, Tianhong
    Sun, Yuanpeng
    Zhang, Peng
    Gao, Jingmei
    Wang, Shanshan
    He, Zhonggui
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (02) : 137 - 141
  • [9] Fully Validated Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Fimasartan in Human Plasma
    Ji Yeon Hyun
    Hyun-Ju Kim
    Mi-Ri Gwon
    Hae Won Lee
    Sook Jin Seong
    Young-Ran Yoon
    Analytical Sciences, 2015, 31 : 1335 - 1339
  • [10] Highly sensitive ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of abiraterone in human plasma
    Wani, Tanveer A.
    ANALYTICAL METHODS, 2013, 5 (15) : 3693 - 3699