Validation of an ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of flecainide in human plasma and its clinical application

被引:5
|
作者
Mano, Yuji [1 ]
Asakawa, Yoshiki [2 ]
Kita, Kenji [2 ]
Ishii, Takuho [2 ]
Hotta, Koichiro [1 ]
Kusano, Kazutomi [1 ]
机构
[1] Eisai & Co Ltd, Biopharmaceut Assessment Core Funct Unit, Drug Metab & Pharmacokinet, Tsukuba, Ibaraki 3002635, Japan
[2] Sunplanet Co Ltd, Tsukuba Div, Anal Grp, Tsukuba, Ibaraki 3002635, Japan
关键词
UPLC-MS; MS; flecainide; validation; ISR; hemolysis; SUPRAVENTRICULAR TACHYCARDIA; SERUM FLECAINIDE; CHILDREN; THERAPY;
D O I
10.1002/bmc.3437
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple and reproducible bioanalytical method for the determination of flecainide in human plasma was developed and validated using an ultra-performance liquid chromatography with tandem mass spectrometry (UPLC-MS/MS) to obtain higher sensitivity than the current available methods. After simple protein precipitation, flecainide and a stable isotope-labeled internal standard (IS) were chromatographed on an Acquity UPLC BEH C-18 column (2.1 x 100 mm, 1.7 mu m) with isocratic elution of mobile phase consisting of 45% methanol containing 0.1% formic acid at a flow rate 0.25 mL/min. Detection was performed in positive electrospray ionization by monitoring the selected ion transitions at m/z 415.4/301.1 for flecainide and m/z 419.4/305.1 for the IS. The method was validated according to current bioanalytical method validation guidelines. The calibration standard curve was linear from 2.5 to 1000 ng/mL using 0.1 mL of plasma. No significant interferences were detected in blank human plasma. Accuracy and precision in the intra- and inter-batch reproducibility study were within acceptance criteria. Neither hemolysis effects nor matrix effects were observed. The UPLC-MS/MS method developed was successfully applied to determine plasma flecainide concentrations to support clinical studies and incurred sample reanalysis also ensured the reproducibility of the method. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:1399 / 1405
页数:7
相关论文
共 50 条
  • [41] Determination of artemisitene in rat plasma by ultra-performance liquid chromatography/tandem mass spectrometry and its application in pharmacokinetics
    Wu, Li-lan
    Wu, Yun-Shan
    Chen, Wei-Ying
    Zhou, Wen
    Tang, Lipeng
    Li, Ben
    Liu, Bo
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2017, 31 (13) : 1121 - 1128
  • [42] Determination of febuxostat in human plasma using ultra-performance liquid chromatography tandem mass spectrometry
    Lukram, Ojikumar
    Parmar, Shivaji
    Hande, Amit
    DRUG TESTING AND ANALYSIS, 2013, 5 (06) : 492 - 499
  • [43] Determination of eugenitin in mouse blood by ultra-performance liquid chromatography-tandem mass spectrometry and its application to a pharmacokinetic study
    Lin, Chongliang
    Song, Dezhen
    Jiang, Haodong
    Luo, Lvqi
    Bao, Xi
    Yu, Xiaomin
    Ma, Jianshe
    Wang, Xianqin
    Jiang, Xiajuan
    ACTA CHROMATOGRAPHICA, 2022, 34 (03) : 253 - 257
  • [44] Simultaneous determination of remimazolam and its carboxylic acid metabolite in human plasma using ultra-performance liquid chromatography-tandem mass spectrometry
    Zhou, Ying
    Wang, Hongyun
    Jiang, Ji
    Hu, Pei
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 976 : 78 - 83
  • [45] Determination of Pesticide Residues in Strawberries by Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry
    Hui Wang
    Hua Ping
    Qingju Liu
    Ping Han
    Xiaojun Guo
    Food Analytical Methods, 2022, 15 : 85 - 95
  • [46] Determination of Ethylglucuronide in Oral Fluid by Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Hegstad, S.
    Johnsen, L.
    Morland, J.
    Christophersen, A. S.
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2009, 33 (04) : 204 - 207
  • [47] Determination of Pesticide Residues in Strawberries by Ultra-performance Liquid Chromatography-Tandem Mass Spectrometry
    Wang, Hui
    Ping, Hua
    Liu, Qingju
    Han, Ping
    Guo, Xiaojun
    FOOD ANALYTICAL METHODS, 2022, 15 (01) : 85 - 95
  • [48] Determination and Validation of Imperialine in Rat Plasma by Ultra-Performance Liquid-Chromatography with Tandem Mass Spectrometry
    Wu, Qing
    Wang, Chunjie
    Lin, Yingying
    Yang, Suping
    Wu, Yinan
    Fan, Linyu
    Gu, Kaiwen
    Hu, Yue
    Wen, Congcong
    Lin, Chongliang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (09): : 1836 - 1841
  • [49] Development and validation of an ultra performance liquid chromatography-tandem mass spectrometry method for the quantification of daptomycin in human plasma
    Bazoti, Fotini N.
    Gikas, Evangelos
    Skoutelis, Athanasios
    Tsarbopoulos, Anthony
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (01) : 78 - 85
  • [50] Simultaneous quantification of atenolol and chlorthalidone in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry
    Shah, Jaivik V.
    Patel, Daxesh P.
    Shah, Priyanka A.
    Sanyal, Mallika
    Shrivastav, Pranav S.
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (02) : 208 - 216