An ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of obeticholic acid in rat plasma and its application in preclinical pharmacokinetic studies

被引:6
|
作者
Li, Xiang-yu [1 ]
Zhu, Sheng-hong [2 ]
Yang, Fang [1 ]
Hu, Guo-xin [3 ]
Yuan, Ling-jing [4 ]
机构
[1] Shaoxing Keqiao Women & Childrens Hosp, Dept Pharm, Shaoxing, Zhejiang, Peoples R China
[2] Shaoxing Keqiao Women & Childrens Hosp, Dept Sci Educ, Shaoxing, Zhejiang, Peoples R China
[3] Wenzhou Med Univ, Dept Pharmacol, Sch Pharm, Wenzhou, Zhejiang, Peoples R China
[4] Shaoxing Second Hosp, Dept Pharm, Shaoxing, Zhejiang, Peoples R China
关键词
Obeticholic acid; Ultra-performance liquid chromatography-tandem mass spectrometry; Rat plasma; Pharmacokinetics; PRIMARY BILIARY-CIRRHOSIS; FARNESOID-X RECEPTOR; BIOCHEMICAL RESPONSE; NUCLEAR RECEPTOR; FXR;
D O I
10.1016/j.jchromb.2019.05.011
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Currently, ursodeoxycholic acid (UDCA) is the only clear medical treatment for primary biliary cholangitis (PBC). However, approximately 40% of patients are not sensitive to UDCA. In recent years, obeticholic acid (OCA) combined with UDCA has been used in the PBC patients who were not sensitive to UDCA, or as mono-therapy for PBC adult patients who are intolerant to UDCA. Objective: To develop and validate a specific, sensitive and reliable tandem mass spectrometry (UPLC-MS/MS) method for the determination of obeticholic acid (OCA) in rat plasma. Methods: Plasma samples were treated with liquid-liquid extraction. Diazepam was selected as the internal standard (IS). Chromatographic separation was achieved by an Acquity BEH C18 column (2.1 mm x 50 mm, 1.7 mu m) and a mobile phase consisting of acetonitrile and ultrapure water (containing 0.1% formic acid). The analyte was detected in positive ion mode by electrospray ionization mass spectrometry (ESI-MS). Multiple reaction monitoring (MRM) methods were used to detect specific precursor and product ions. The target ion pair of OCA was 419.38 -> 401.22, and the IS was 285.05 -> 193.02. Results: The linear range of OCA in rat plasma was 0.05-50 mu g/mL (R-2 = 0.992); the recovery rate was 91.34%-97.37%. This assay showed good intra- and inter-day precision and accuracy. No significant matrix effects in this study. Conclusion: A specific, sensitive and reliable quantitative analysis method was established to detect OCA after oral/intravenous administration in rat plasma via UPLC-MS/MS. It was appropriate for preclinical pharmacokinetic studies of OCA.
引用
收藏
页码:82 / 88
页数:7
相关论文
共 50 条
  • [1] Development and validation of an ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of baloxavir in rat plasma and its application to pharmacokinetic studies
    Mu, Hongli
    Zhang, Wenyu
    Song, Yuanming
    Liang, Rui
    Zhao, Hengli
    Song, Chunhong
    Wen, Qing
    BIOMEDICAL CHROMATOGRAPHY, 2023, 37 (11)
  • [2] Development and validation of an ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of baloxavir in rat plasma and its application to pharmacokinetic studies
    Mu, Hongli
    Zhang, Wenyu
    Song, Yuanming
    Liang, Rui
    Zhao, Hengli
    Song, Chunhong
    Wen, Qing
    BIOMEDICAL CHROMATOGRAPHY, 2023,
  • [3] An Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry Method for the Determination of Deoxycholic Acid and Application to a Pharmacokinetic Study in Human Plasma
    Xi, Wanlin
    Fu, Diyi
    Wu, Ni
    Liu, Fei
    Zhang, Cuixia
    Wan, Ruijie
    Wu, Zhen
    Chen, Rui
    Zhao, Qian
    BIOMEDICAL CHROMATOGRAPHY, 2025, 39 (02)
  • [4] Ultra-performance liquid chromatography-tandem mass spectrometry method for the determination of febuxostat in dog plasma and its application to a pharmacokinetic study
    Zhang, Tianhong
    Sun, Yuanpeng
    Zhang, Peng
    Gao, Jingmei
    Wang, Shanshan
    He, Zhonggui
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (02) : 137 - 141
  • [5] Ultra-performance liquid chromatography-tandem mass spectrometry for the determination of lacidipine in human plasma and its application in a pharmacokinetic study
    Tang, Jing
    Zhu, Ronghua
    Zhao, Ruike
    Cheng, Gang
    Peng, Wenxing
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 47 (4-5) : 923 - 928
  • [6] Determination of dapoxetine in rat plasma by ultra-performance liquid chromatography-tandem mass spectrometry
    Kim, Tae Kon
    Kim, In Sook
    Hong, Seok Hyun
    Choi, Yun Kyoung
    Kim, Hohyun
    Yoo, Hye Hyun
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 926 : 42 - 46
  • [7] A Sensitive Ultra-performance Liquid Chromatography-Tandem Mass Spectrometric Method for Determination of Secalonic Acid F in Rat Plasma and Its Application to Pharmacokinetic Study
    Ji, Lei
    Wang, Pengyue
    Wan, Qingyun
    Wang, Gege
    Liu, Weizhong
    Liu, Desheng
    JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2024, 62 (03) : 281 - 286
  • [8] Determination of mycophenolic acid in human plasma by ultra-performance liquid chromatography-tandem mass spectrometry and its pharmacokinetic application in kidney transplant patients
    Eduardo Resendiz-Galvan, Juan
    Romano-Aguilar, Melissa
    Edith Medellin-Garibay, Susanna
    del Carmen Milan-Segovia, Rosa
    Chevaile-Ramos, Alejandro
    Romano-Moreno, Silvia
    BIOMEDICAL CHROMATOGRAPHY, 2019, 33 (12)
  • [9] Determination and Pharmacokinetics of Delsoline in Rat Plasma by Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Cai, Yuan
    Zhou, Caiping
    Chen, Yuyan
    Liang, Qishun
    Hu, Manman
    Chen, Lianguo
    LATIN AMERICAN JOURNAL OF PHARMACY, 2021, 40 (03): : 633 - 636
  • [10] Simultaneous determination of dexamethasone and lenalidomide in rat plasma by solid phase extraction and ultra-performance liquid chromatography-tandem mass spectrometry: application to pharmacokinetic studies
    Maher, Hadir M.
    Alzoman, Nourah Z.
    Alshehri, Mona M.
    Aljohar, Haya I.
    Shehata, Shereen
    Alossaimi, Manal
    Abanmy, Norah O.
    RSC ADVANCES, 2015, 5 (119) : 98600 - 98609