Microhardness of resin composites polymerized by plasma arc or conventional visible light curing

被引:0
|
作者
Park, SH [1 ]
Krejci, I [1 ]
Lutz, F [1 ]
机构
[1] NHIC, Ilsan Hosp, Dept Conservat Dent, Iksan Gu, Seoul, South Korea
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the effectiveness of the plasma are curing (PAC) unit for composite curing. To compare its effectiveness with conventional quartz tungsten halogen (QTH) light curing units, the microhardness of two composites (Z100 and Tetric Ceram) that had been light cured by the PAC or QTH units, were compared according to the depth from, the composite surface. In addition, linear polymerization shrinkage was compared using a custom-made linometer between composites which were light cured by PAC or QTH units. Measuring polymerization shrinkage for two resin composites Z100 and Tetric Ceram) was performed after polymerization with either QTH or PAC units. In the case of curing with the PAC unit, the composite was light cured with Apollo 95E for two (Group 1), three (Group 2), six (Group 3) or 2 x 6 (Group 4) seconds. For light curing with the QTH unit, the composite was light cured for 60 seconds with Optilux 500 (Group 5). The linear polymerization shrinkage of composites was determined in the linometer. Two resin composites were used to measure microhardness. Two-mm. thick samples were light cured for three seconds (Group 1), six seconds (Group 2) or 12 (2 x 6) seconds (Group 3) with Apollo 95E or they were conventionally light cured with Optilux 500 for 30 seconds (Group 4) or 60 seconds (Group 5). For 3 mm thick samples, the composites were light cured for six seconds (Group 1), 12 (2 x 6) seconds (Group 2) or 18 (3 x 6) seconds (Group 3) with Apollo 95E or they were conventionally light cured with Optilux 500 for 30 seconds (Group 4) or 60 seconds (Group 5). Twenty samples were assigned to each group. The microhardness of the upper and lower surfaces was measured with a Vickers hardness-measuring instrument under load. The difference in microhardness between the upper and lower surfaces in each group was analyzed by paired t-test. For the upper or lower surfaces, one-way ANOVA with Tukey was used. For Tetric Ceram, the amount of polymerization shrinkage was lower when cured with the Apollo 95E for two or three seconds than when cured for six and 12 (2 x 6) seconds, or for 60 seconds with Optilux 500 (p<0.05). For Z100, the amount of linear polymerization shrinkage was lower when cured with the Apollo 95E for two, three and six seconds than for 12 (2 x 6) seconds with Apollo 95E or for 60 seconds with the Optilux 500 (p<0.05). The results of the microhardness test indicated that there was no statistically significant difference in microhardness between groups for the upper surface. However, for the lower surface, when the composites were light cured with Apollo 95E for three seconds as recommended by the manufacturer, microhardness of the lower surface was usually lower than that of the upper surface and did not cure sufficiently. Conclusively, when compared with conventional QTH unit, the PAC unit, Apollo 95E did not properly cure the lower composite surface when the layer thickness exceeded 2 mm. In addition, three seconds of curing time, which the manufacturer recommended, was insufficient for optimal curing of composites.
引用
收藏
页码:30 / 37
页数:8
相关论文
共 50 条
  • [41] Direction of shrinkage of light-curing resin composites
    Asmussen, E
    Peutzfeldt, A
    ACTA ODONTOLOGICA SCANDINAVICA, 1999, 57 (06) : 310 - 315
  • [42] Change of color and translucency by light curing in resin composites
    Sidhu, S. K.
    Ikeda, T.
    Omata, Y.
    Fujita, M.
    Sano, H.
    OPERATIVE DENTISTRY, 2006, 31 (05) : 598 - 603
  • [43] Microhardness and microleakage of composite resin according to the change of curing light intensity.
    Shin, DH
    Cho, KM
    Park, SM
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A88 - A88
  • [44] Reaction of Rat Subcutaneous Connective Tissue to Resin Composites Polymerized with Different Light Curing Units and Different Lightening Methods
    Feiz, Atiyeh
    Zavareh, Farahnaz Arbabzadeh
    Razavi, Seyed Mohammad
    Badrian, Hamid
    Dolatyar, Sepideh
    Vajihi, Mansoureh
    INTERNATIONAL JOURNAL OF DENTISTRY, 2012, 2012
  • [45] Surface microhardness of a plasma arc-cured resin composite.
    Hickey, A
    Lynch, CD
    Ray, N
    Hannigan, A
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : B297 - B297
  • [46] Effectiveness at plasma arc curing for composite resin polymerization.
    Pelossi, PL
    Macchi, RL
    JOURNAL OF DENTAL RESEARCH, 2000, 79 (05) : 1014 - 1014
  • [47] THE CURING PATTERN OF VISIBLE-LIGHT CURED COMPOSITES
    BAUSCH, JR
    DELANGE, C
    DAVIDSON, CL
    JOURNAL OF DENTAL RESEARCH, 1983, 62 (04) : 451 - 451
  • [48] CURING DEPTH OF VISIBLE LIGHT-ACTIVATED COMPOSITES
    FORSTEN, L
    ACTA ODONTOLOGICA SCANDINAVICA, 1984, 42 (01) : 23 - 28
  • [49] CURING DEPTH OF VISIBLE-LIGHT CURED COMPOSITE RESIN
    SKEETERS, TM
    TIMMONS, JH
    MITCHELL, RJ
    JOURNAL OF DENTAL RESEARCH, 1983, 62 : 219 - 219
  • [50] Time reduction of light curing: Influence on conversion degree and microhardness of orthodontic composites
    Ferreira Amato, Patricia Alves
    Martins, Renato Parsekian
    dos Santos Cruz, Carlos Alberto
    Capella, Marisa Veiga
    Martins, Lidia Parsekian
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 146 (01) : 40 - 46