Microhardness of resin composites polymerized by plasma arc or conventional visible light curing

被引:0
|
作者
Park, SH [1 ]
Krejci, I [1 ]
Lutz, F [1 ]
机构
[1] NHIC, Ilsan Hosp, Dept Conservat Dent, Iksan Gu, Seoul, South Korea
关键词
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the effectiveness of the plasma are curing (PAC) unit for composite curing. To compare its effectiveness with conventional quartz tungsten halogen (QTH) light curing units, the microhardness of two composites (Z100 and Tetric Ceram) that had been light cured by the PAC or QTH units, were compared according to the depth from, the composite surface. In addition, linear polymerization shrinkage was compared using a custom-made linometer between composites which were light cured by PAC or QTH units. Measuring polymerization shrinkage for two resin composites Z100 and Tetric Ceram) was performed after polymerization with either QTH or PAC units. In the case of curing with the PAC unit, the composite was light cured with Apollo 95E for two (Group 1), three (Group 2), six (Group 3) or 2 x 6 (Group 4) seconds. For light curing with the QTH unit, the composite was light cured for 60 seconds with Optilux 500 (Group 5). The linear polymerization shrinkage of composites was determined in the linometer. Two resin composites were used to measure microhardness. Two-mm. thick samples were light cured for three seconds (Group 1), six seconds (Group 2) or 12 (2 x 6) seconds (Group 3) with Apollo 95E or they were conventionally light cured with Optilux 500 for 30 seconds (Group 4) or 60 seconds (Group 5). For 3 mm thick samples, the composites were light cured for six seconds (Group 1), 12 (2 x 6) seconds (Group 2) or 18 (3 x 6) seconds (Group 3) with Apollo 95E or they were conventionally light cured with Optilux 500 for 30 seconds (Group 4) or 60 seconds (Group 5). Twenty samples were assigned to each group. The microhardness of the upper and lower surfaces was measured with a Vickers hardness-measuring instrument under load. The difference in microhardness between the upper and lower surfaces in each group was analyzed by paired t-test. For the upper or lower surfaces, one-way ANOVA with Tukey was used. For Tetric Ceram, the amount of polymerization shrinkage was lower when cured with the Apollo 95E for two or three seconds than when cured for six and 12 (2 x 6) seconds, or for 60 seconds with Optilux 500 (p<0.05). For Z100, the amount of linear polymerization shrinkage was lower when cured with the Apollo 95E for two, three and six seconds than for 12 (2 x 6) seconds with Apollo 95E or for 60 seconds with the Optilux 500 (p<0.05). The results of the microhardness test indicated that there was no statistically significant difference in microhardness between groups for the upper surface. However, for the lower surface, when the composites were light cured with Apollo 95E for three seconds as recommended by the manufacturer, microhardness of the lower surface was usually lower than that of the upper surface and did not cure sufficiently. Conclusively, when compared with conventional QTH unit, the PAC unit, Apollo 95E did not properly cure the lower composite surface when the layer thickness exceeded 2 mm. In addition, three seconds of curing time, which the manufacturer recommended, was insufficient for optimal curing of composites.
引用
收藏
页码:30 / 37
页数:8
相关论文
共 50 条
  • [21] A titanium and visible light-polymerized resin obturator
    Rilo, B
    da Silva, JL
    Martinez-Insua, A
    Santana, U
    JOURNAL OF PROSTHETIC DENTISTRY, 2002, 87 (04): : 407 - 409
  • [22] The effect of light curing units, curing time, and veneering materials on resin cement microhardness
    Ilday, Nurcan Ozakar
    Bayindir, Yusuf Ziya
    Bayindir, Funda
    Gurpinar, Aysel
    JOURNAL OF DENTAL SCIENCES, 2013, 8 (02) : 141 - 146
  • [23] Effect of thermocycling on microleakage of resin composites polymerized with LED curing techniques
    Nalcaci, Adil
    Ulusoy, Nuran
    QUINTESSENCE INTERNATIONAL, 2007, 38 (07): : E433 - E439
  • [24] Flexural strengths of fiber-reinforced composites polymerized with conventional light-curing and additional postcuring
    Cacciafesta, Vittorio
    Sfondrini, Maria Francesca
    Lena, Alessandro
    Scribante, Andrea
    Vallittu, Pekka K.
    Lassila, Lippo V.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2007, 132 (04) : 524 - 527
  • [25] The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites
    Matej Par
    Igor Repusic
    Hrvoje Skenderovic
    Ognjen Milat
    Jelena Spajic
    Zrinka Tarle
    Clinical Oral Investigations, 2019, 23 : 3777 - 3788
  • [26] The effects of extended curing time and radiant energy on microhardness and temperature rise of conventional and bulk-fill resin composites
    Par, Matej
    Repusic, Igor
    Skenderovic, Hrvoje
    Milat, Ognjen
    Spajic, Jelena
    Tarle, Zrinka
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (10) : 3777 - 3788
  • [27] Influence of the Different Light-Curing TIPS in the Microhardness of a Composite Resin
    Dobrovolski, Max
    Busato, Priscilla do Monte R.
    Mendonca, Marcio J.
    Bosquirolli, Virginia
    Santos, Rosana A.
    Camilotti, Veridiana
    POLIMEROS-CIENCIA E TECNOLOGIA, 2010, 20 : 327 - 330
  • [28] Effect of new light curing units on microleakage and microhardness of resin sealants
    Bani, Mehmet
    Tirali, Resmiye Ebru
    DENTAL MATERIALS JOURNAL, 2016, 35 (03) : 517 - 522
  • [29] Impact of the distance of light curing on the degree of conversion and microhardness of a composite resin
    Catelan, Anderson
    Napoleao De Araujo, Larissa Sgarbosa
    Martins Da Silveira, Bruna Cilene
    Kawano, Yoshio
    Bovi Ambrosano, Glaucia Maria
    Marchi, Giselle Maria
    Baggio Aguiar, Flavio Henrique
    ACTA ODONTOLOGICA SCANDINAVICA, 2015, 73 (04) : 298 - 301
  • [30] Effect of Light Curing Methods on Microleakage and Microhardness of Different Resin Sealants
    Duangthip, Duangporn
    Ballungpattama, Suda
    Sitthisettapong, Thanya
    JOURNAL OF DENTISTRY FOR CHILDREN, 2011, 78 (02): : 88 - 95