Gated Myocardial Perfusion SPECT: Algorithm-Specific Influence of Reorientation on Calculation of Left Ventricular Volumes and Ejection Fraction

被引:9
|
作者
Knollmann, Daniela [1 ]
Winz, Oliver H. [1 ]
Meyer, Philipp T. [1 ]
Raptis, Mardjan [1 ]
Krohn, Thomas [1 ]
Koch, Karl-Christian [2 ]
Schaefer, Wolfgang M. [1 ]
机构
[1] Rhein Westfal TH Aachen, Univ Hosp Aachen, Dept Nucl Med, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Univ Hosp Aachen, Med Clin Cardiol 1, D-52074 Aachen, Germany
关键词
gated SPECT; QGS; 4D-MSPECT; CARE heart; reorientation;
D O I
10.2967/jnumed.108.050484
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gated myocardial perfusion SPECT allows calculation of end-diastolic and end-systolic volumes (EDV and ESV, respectively) and left ventricular ejection fraction (LVEF). The quantification algorithms QGS (quantitative gated SPECT), 4D-MSPECT, and CARE heart show a good correlation with cardiac MRI. Nevertheless, differences in contour finding suggest algorithm-specific effects if heart axes vary. The effect of tilting heart axes on gated SPECT was quantified as a possible source of error. Methods: Sixty men underwent gated SPECT (450 MBq of Tc-99m-tetrofosmin or sestamibi, 8 gates/cycle). After correct reorientation (R-0), datasets were tilted by 5, 10, 15, 20, 30, and 45 along both long axes (R-5, R-10, R-15, R-20, R-30, and R-45, respectively). EDV, ESV, and LVEF were calculated using QGS, 4D-MSPECT, and CARE heart. Because a 15 tilt could be a maximum possible misreorientation in routine, R-0 and R-15 results were analyzed in detail. Absolute-difference values between results of tilted and correctly reoriented datasets were calculated for all tilts and algorithms. Results: QGS and CARE heart succeeded for R-0 and R-15 in all cases, whereas 4D-MSPECT failed to find the basal plane in 1 case (patient B). R-2 values between paired R-15/R-0 results were 0.992 (QGS), 0.796 (4D-MSPECT; R-2 = 0.919 inn = 59 after exclusion of the failed case), and 0.916 (CARE heart) for EDV; 0.994 (QGS), 0.852 (4D-MSPECT; R-2 = 0.906 in n = 59), and 0.899 (CARE heart) for ESV; and 0.988 (QGS), 0.814 (4D-MSPECT; R-2 = 0.810 in n = 59), and 0.746 (CARE heart) for LVEF Concerning all levels of misreorientation, 1 patient was excluded for all algorithms because of multiple problems in contour finding; additionally for 4D-MSPECT patient B was excluded. In the 45 group, QGS succeeded in 58 of 59 cases, 4D-MSPECT in 58 of 58, and CARE heart in 33 of 59. Mean absolute differences for EDV ranged from 5.1 +/- 4.1 to 12.8 +/- 10.5 mL for QGS, from 6.7 +/- 6.3 to 34.2 +/- 20.7 mL for 4D-MSPECT, and from 5.4 +/- 5.6 to 25.2 +/- 16.1 mL for CARE heart (tilts between 5 and 45). Mean absolute differences for ESV ranged from 4.1 +/- 3.7 to 8.0 +/- 9.4 mL for QGS, from 5.6 +/- 8.0 to 10.0 +/- 10.5 mL for 4D-MSPECT, and from 5.4 +/- 5.6 to 25.5 +/- 16.1 mLfor CARE heart. Mean absolute differences for LVEF ranged from 1.1% +/- 1.0% to 2.2% +/- 1.8% for QGS, from 4.0% +/- 3.5% +/- to 8.0% +/- 7.1 for 4D-MSPECT, and from 3.4% +/- 2.9% to 9.2% +/- 6.0% for CARE heart. Conclusion: Despite tilted heart axes, QGS showed stable results even when using tilts up to 45. 4D-MSPECT and CARE heart results varied with reorientation of the heart axis, implying that published validation results apply to correctly reoriented data only.
引用
收藏
页码:1636 / 1642
页数:7
相关论文
共 50 条
  • [41] Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT
    Seong-Jang Kim
    In-Ju Kim
    Yun-Seong Kim
    Yong-Ki Kim
    The International Journal of Cardiovascular Imaging, 2005, 21 : 261 - 266
  • [42] Gated blood pool SPECT for measurement of left ventricular volumes and left ventricular ejection fraction: comparison of 8 and 16 frame gated blood pool SPECT
    Kim, SJ
    Kim, IJ
    Kim, YS
    Kim, YK
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (2-3): : 261 - 266
  • [43] New hardware, new software, different results: The estimation of left ventricular volumes and ejection fractions with gated myocardial perfusion SPECT
    Mark F. Smith
    Journal of Nuclear Cardiology, 2020, 27 : 1725 - 1727
  • [44] New hardware, new software, different results: The estimation of left ventricular volumes and ejection fractions with gated myocardial perfusion SPECT
    Smith, Mark F.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (05) : 1725 - 1727
  • [45] Assessment of three software packages in the estimation of left ventricular volumes and ejection fraction with resolution recovery algorithm in gated myocardial perfusion SPECT vs cMRI: preliminary results of a single centre
    Calandri, E.
    Guana, F.
    Conversano, L.
    Gallina, S.
    Leuzzi, S.
    Soligo, E.
    Debernardi, S.
    Liberatore, M.
    Chiorino, G.
    Pultrone, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S768 - S768
  • [46] Gender differences in ventricular volumes and left ventricle ejection fraction estimated by myocardial perfusion imaging: Comparison of Quantitative Gated SPECT (QGS) and Segami software programs
    Yamada, Alice Tatsuko
    de Carvalho Campos Neto, Guilherme
    Soares, Jose, Jr.
    Giorgi, Maria Clementina P.
    Arajo, Fernando
    Meneghetti, Jose Claudio
    Mansur, Alfredo Jose
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2007, 88 (03) : 285 - 290
  • [47] Rest Versus Stress Ejection Fraction on Gated Myocardial Perfusion SPECT
    Wheat, Janelle M.
    Currie, Geoffrey M.
    JOURNAL OF NUCLEAR MEDICINE TECHNOLOGY, 2005, 33 (04) : 218 - 223
  • [48] AUTOMATIC QUANTIFICATION OF EJECTION FRACTION FROM GATED MYOCARDIAL PERFUSION SPECT
    GERMANO, G
    KIAT, H
    KAVANAGH, PB
    MORIEL, M
    MAZZANTI, M
    SU, HT
    VANTRAIN, KF
    BERMAN, DS
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (11) : 2138 - 2147
  • [49] Evaluation of left ventricular volumes and ejection fraction by gated SPECT and cardiac MRI in patients with dilated cardiomyopathy
    Feng Wang
    Jian Zhang
    Wei Fang
    Shi-Hua Zhao
    Min-Jie Lu
    Zuo-Xiang He
    European Journal of Nuclear Medicine and Molecular Imaging, 2009, 36 : 1611 - 1621
  • [50] Left ventricular ejection fraction and volumes on rest gated 201TI perfusion SPECT:: Comparison with two-dimensional echocardiography
    Patel, CD
    Nadig, MR
    Kurien, S
    Barai, S
    Narang, R
    Malhotra, A
    NUCLEAR MEDICINE COMMUNICATIONS, 2006, 27 (05) : 425 - 429