Single-loop coil concepts for intravascular magnetic resonance imaging

被引:0
|
作者
Quick, HH
Ladd, ME
Zimmermann-Paul, GG
Erhart, P
Hofmann, E
von Schulthess, GK
Debatin, JF
机构
[1] Univ Zurich Hosp, Dept Radiol, CH-8091 Zurich, Switzerland
[2] Schneider Europe AG, Bulach, Switzerland
关键词
intravascular magnetic resonance imaging; single-loop coil; signal-to-noise ratio; balloon catheter;
D O I
10.1002/(SICI)1522-2594(199904)41:4<751::AID-MRM14>3.3.CO;2-M
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Compared with other coil designs that have been investigated for intravascular use, the single-loop coil can be designed with a very small diameter for insertion into small vessels and with a longitudinal extent over several centimeters for multislice imaging. If it designed to be expandable inside the target vessel, then it combines these features with increased signal-to-noise ratio (SNR) and penetration depth, Expandable single-loop coils that are capable of meeting these requirements were developed and integrated into two different commercial catheter-based delivery systems: a self-expandable, single-loop made from NiTinol and a single-loop coil mounted an an inflatable balloon. The influence of a small-diameter coaxial cable for remote tuning and matching on the coil performance was investigated. Calculations showed the dependence of the signal on the separation between the conductors. The comparison of both catheter approaches in in vitro flow experiments and in an in vivo pig experiment revealed the influence of pulsatile flow on image quality during intravascular imaging with these designs. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:751 / 758
页数:8
相关论文
共 50 条
  • [41] A 2-in-1 single-element coil design for transcranial magnetic stimulation and magnetic resonance imaging
    Lu, Hai
    Wang, Shumin
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (01) : 582 - 587
  • [42] Cancer imaging: novel concepts in clinical magnetic resonance imaging
    Kwee, T. C.
    Takahara, T.
    Klomp, D. W. J.
    Luijten, P. R.
    JOURNAL OF INTERNAL MEDICINE, 2010, 268 (02) : 120 - 132
  • [43] Multi-Loop Radio Frequency Coil Elements for Magnetic Resonance Imaging: Theory, Simulation, and Experimental Investigation
    Frass-Kriegl, Roberta
    Hosseinnezhadian, Sajad
    Poirier-Quinot, Marie
    Laistler, Elmar
    Ginefri, Jean-Christophe
    FRONTIERS IN PHYSICS, 2020, 7
  • [44] Restoring single-loop integrity to process control
    Rezabek, John
    HYDROCARBON PROCESSING, 2007, 86 (11): : 19 - 19
  • [45] Intravascular magnetic resonance imaging using a loopless catheter antenna
    Ocali, O
    Atalar, E
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (01) : 112 - 118
  • [46] Hemodynamic tolerance of intravascular contrast agents for magnetic resonance imaging
    Knollmann, FD
    Sorge, R
    Muhler, A
    Maurer, J
    Muschick, P
    Bock, JC
    Felix, R
    INVESTIGATIVE RADIOLOGY, 1997, 32 (12) : 755 - 762
  • [47] Real-time intravascular magnetic resonance imaging system
    Hu, BS
    Scott, GC
    Meyer, CH
    Pauly, JM
    Nishimura, DG
    Macovski, A
    CIRCULATION, 1998, 98 (17) : 857 - 857
  • [48] Coronary hematoma visualized by intravascular ultrasound and magnetic resonance imaging
    Maehara, A
    Yamada, N
    Seguchi, O
    Yasuda, S
    Otsuka, Y
    Miyazaki, S
    Yamagishi, M
    CIRCULATION, 2003, 107 (06) : E46 - E46
  • [49] Characterization of human atherosclerotic plaques by intravascular magnetic resonance imaging
    Larose, E
    Yeghiazarians, Y
    Libby, P
    Yucel, EK
    Aikawa, M
    Kacher, DF
    Aikawa, E
    Kinlay, S
    Schoen, FJ
    Selwyn, AP
    Ganz, P
    CIRCULATION, 2005, 112 (15) : 2324 - 2331
  • [50] INTRAVASCULAR CONTRAST AGENTS SUITABLE FOR MAGNETIC-RESONANCE IMAGING
    RUNGE, VM
    CLANTON, JA
    HERZER, WA
    GIBBS, SJ
    PRICE, AC
    PARTAIN, CL
    JAMES, AE
    RADIOLOGY, 1984, 153 (01) : 171 - 176