Single-loop coil concepts for intravascular magnetic resonance imaging

被引:0
|
作者
Quick, HH
Ladd, ME
Zimmermann-Paul, GG
Erhart, P
Hofmann, E
von Schulthess, GK
Debatin, JF
机构
[1] Univ Zurich Hosp, Dept Radiol, CH-8091 Zurich, Switzerland
[2] Schneider Europe AG, Bulach, Switzerland
关键词
intravascular magnetic resonance imaging; single-loop coil; signal-to-noise ratio; balloon catheter;
D O I
10.1002/(SICI)1522-2594(199904)41:4<751::AID-MRM14>3.3.CO;2-M
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Compared with other coil designs that have been investigated for intravascular use, the single-loop coil can be designed with a very small diameter for insertion into small vessels and with a longitudinal extent over several centimeters for multislice imaging. If it designed to be expandable inside the target vessel, then it combines these features with increased signal-to-noise ratio (SNR) and penetration depth, Expandable single-loop coils that are capable of meeting these requirements were developed and integrated into two different commercial catheter-based delivery systems: a self-expandable, single-loop made from NiTinol and a single-loop coil mounted an an inflatable balloon. The influence of a small-diameter coaxial cable for remote tuning and matching on the coil performance was investigated. Calculations showed the dependence of the signal on the separation between the conductors. The comparison of both catheter approaches in in vitro flow experiments and in an in vivo pig experiment revealed the influence of pulsatile flow on image quality during intravascular imaging with these designs. (C) 1999 Wiley-Liss, Inc.
引用
收藏
页码:751 / 758
页数:8
相关论文
共 50 条
  • [31] Design of split coil magnets for Magnetic Resonance Imaging
    Cavaliere, V
    Formisano, A
    Martone, R
    Masullo, G
    Matrone, A
    Primizia, M
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2000, 10 (01) : 759 - 762
  • [32] Static Coil Design Considerations for the Magnetic Resonance Imaging
    Shiravi, M.
    Ganji, B.
    Shiravi, A.
    INTERNATIONAL JOURNAL OF ENGINEERING, 2019, 32 (03): : 393 - 399
  • [33] Magnetic resonance imaging of the sternum with a dedicated breast coil
    Lomasney, LM
    Posniak, HV
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 1998, 49 (01): : 55 - 56
  • [34] Opencage radio frequency coil for magnetic resonance imaging
    Nikulin, A.
    de Rosny, J.
    Haliot, K.
    Larrat, B.
    Ourir, A.
    APPLIED PHYSICS LETTERS, 2019, 114 (05)
  • [35] Endoscopic magnetic resonance imaging at variable coil orientations
    Kulling, D
    Bohning, DE
    Kay, CL
    Feldman, DR
    Hawes, RH
    ENDOSCOPY, 1997, 29 (04) : 336 - 337
  • [36] SINGLE-LOOP DIVERGENCES IN 6 DIMENSIONS
    DOWKER, JS
    JOURNAL OF PHYSICS A-MATHEMATICAL AND GENERAL, 1977, 10 (04): : L63 - L65
  • [37] Hexagonal zero mode coil: A single channel multi-coil design for small animal magnetic resonance Imaging
    Lazovic-Stojkovic, J
    Yang, QX
    Collins, CM
    Liu, WZ
    Vaughan, JT
    Smith, MB
    PROCEEDINGS OF THE IEEE 28TH ANNUAL NORTHEAST BIOENGINEERING CONFERENCE, 2002, : 65 - 66
  • [38] Staging of cervical carcinomas - Comparison of body-coil magnetic resonance imaging and endorectal surface coil magnetic resonance imaging with histopathologic correlation
    Preidler, KW
    Tamussino, K
    Szolar, DM
    Ranner, G
    Ebner, F
    INVESTIGATIVE RADIOLOGY, 1996, 31 (07) : 458 - 462
  • [39] Cylindrical meanderline radiofrequency coil for intravascular magnetic resonance studies of atherosclerotic plaque
    Farrar, CT
    Wedeen, VJ
    Ackerman, JL
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (01) : 226 - 230
  • [40] CONCEPTS OF MYOCARDIAL PERFUSION IMAGING IN MAGNETIC-RESONANCE-IMAGING
    WILKE, N
    JEROSCHHEROLD, M
    STILLMAN, AE
    KROLL, K
    TSEKOS, N
    MERKLE, H
    PARRISH, T
    HU, X
    WANG, Y
    BASSINGTHWAIGHTE, J
    BACHE, RJ
    UGURBIL, K
    MAGNETIC RESONANCE QUARTERLY, 1994, 10 (04) : 249 - 286