Improved quantification of mass fraction of colorants in textile by high-performance liquid chromatography coupled with tandem mass spectrometric detector

被引:3
|
作者
Tolgyesi, Adam [1 ]
Sharma, Virender K. [2 ]
Kulati, Anita [1 ]
机构
[1] EMI TUV SUD Ltd, Dugonics Utca 11, H-1043 Budapest, Hungary
[2] Texas A&M Univ, Program Environm & Sustainabil, Sch Publ Hlth, Dept Environm & Occupat Hlth, 212 Adriance Lab Rd,1266 TAMU, College Stn, TX 77843 USA
关键词
Colorants; Textiles; LC-MS; MS; HPLC-DAD; Standard method; Exact-matching double isotope dilution mass spectrometry; MILD EXTRACTION; DYES; IDENTIFICATION;
D O I
10.1007/s00769-020-01438-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The DIN 54231:2005 and ISO 16373-2:2014 standard methods recommend the application of HPLC separations and detection by either diode array (HPLC-DAD) or mass spectrometric detectors (LC-MS or LC-MS/MS) for the evaluation of mass concentration of colorants (y >= 1.0 mu g/mL) in textile sample extracts. The present investigation reports for the first time that the LC-MS/MS method has low accuracy for most of textile colorants if the recommended calibration range of the standard methods (1.0 mu g/mL to 20 mu g/mL or 5.0 mu g/mL to 50 mu g/mL) is used. The present paper reports that the quantification of mass concentration of colorants in textile extract by the LC-MS/MS method does not match with the quantification by the HPLC-DAD method, which has fit-for-purpose linearity and accuracy in the ranges mentioned above. A systematic study of the MS/MS method was performed to prepare real and spiked samples for quantifying mass concentration of colorants (y <= 1.0 mu g/mL) in textile extracts for compounds having LOQ <= 1.0 mg/kg. The results obtained could match with the quantification by the HPLC-DAD method. A lower calibration range was needed to quantify the dyes in the diluted sample extracts in which the background matrix constituents had lower influence on the quantification. Significantly, the LC-MS/MS method utilizing sample dilution and lower calibration range was validated and then used to proficiency test (PT) samples with success. Furthermore, the evaluation of mass fraction of disperse yellow 3 in PT sample by exact-matching double isotope dilution mass spectrometry was also performed. The strategy presented herein to quantify a wide range of colorants using the LC-MS/MS method could improve the reproducibility of analyzing colorants using protocols of standard recommendations.
引用
收藏
页码:259 / 272
页数:14
相关论文
共 50 条
  • [41] Speciation of chromium dyes by high-performance liquid chromatography with inductively coupled plasma mass spectrometric detection
    Zoorob, GK
    Caruso, JA
    JOURNAL OF CHROMATOGRAPHY A, 1997, 773 (1-2) : 157 - 162
  • [42] High-performance liquid chromatography - Tandem mass spectrometry of cardiac steroids
    Higashi, T
    Nakayama, N
    Shimada, K
    Kasai, H
    Nakazawa, H
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 1999, 22 (15) : 2283 - 2296
  • [43] Quantification of Warfarin in Dried Rat Plasma Spots by High-Performance Liquid Chromatography with Tandem Mass Spectrometry
    Chernonosov, Alexander
    JOURNAL OF PHARMACEUTICS, 2016, 2016
  • [44] Simultaneous quantification of tacrolimus and sirolimus, in human blood, by high-performance liquid chromatography - Tandem mass spectrometry
    Taylor, PJ
    Salm, P
    Lynch, SV
    Pillans, PI
    THERAPEUTIC DRUG MONITORING, 2000, 22 (05) : 608 - 612
  • [45] Bioanalytical Method for the Determination of Hydroxyproline in Mouse Kidney by High-Performance Liquid Chromatography with Tandem Mass Spectrometric Detection
    Rika Shiota
    Hirotoshi Morita
    Tomoko Matsumoto
    Atsushi Morimoto
    Jun Hayakawa
    Masako Oka
    Hiroshi Kamimori
    Analytical Sciences, 2017, 33 : 719 - 722
  • [46] Bioanalytical Method for the Determination of Hydroxyproline in Mouse Kidney by High-Performance Liquid Chromatography with Tandem Mass Spectrometric Detection
    Shiota, Rika
    Morita, Hirotoshi
    Matsumoto, Tomoko
    Morimoto, Atsushi
    Hayakawa, Jun
    Oka, Masako
    Kamimori, Hiroshi
    ANALYTICAL SCIENCES, 2017, 33 (06) : 719 - 722
  • [47] Quantification of aromatic amines derived from azo colorants in textile by ion-pairing liquid chromatography tandem mass spectrometry
    Tolgyesi, Adam
    Sharma, Virender K.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2020, 1137 (1137):
  • [48] Phytochemical Characterization for Quality Control of Phyllostachys pubescens Leaves Using High-Performance Liquid Chromatography Coupled with Diode Array Detector and Tandem Mass Detector
    Seo, Chang-Seob
    Song, Kwang-Hoon
    PLANTS-BASEL, 2022, 11 (01):
  • [49] Gabapentin quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study
    Ifa, DR
    Falci, M
    Moraes, ME
    Bezerra, FAF
    Moraes, MO
    de Nucci, G
    JOURNAL OF MASS SPECTROMETRY, 2001, 36 (02): : 188 - 194
  • [50] Nevirapine quantification in human plasma by high-performance liquid chromatography coupled to electrospray tandem mass spectrometry. Application to bioequivalence study
    Laurito, TL
    Santagada, V
    Caliendo, G
    Oliveira, CH
    Barrientos-Astigarraga, RE
    De Nucci, G
    JOURNAL OF MASS SPECTROMETRY, 2002, 37 (04): : 434 - 441