Improved quantification of mass fraction of colorants in textile by high-performance liquid chromatography coupled with tandem mass spectrometric detector

被引:3
|
作者
Tolgyesi, Adam [1 ]
Sharma, Virender K. [2 ]
Kulati, Anita [1 ]
机构
[1] EMI TUV SUD Ltd, Dugonics Utca 11, H-1043 Budapest, Hungary
[2] Texas A&M Univ, Program Environm & Sustainabil, Sch Publ Hlth, Dept Environm & Occupat Hlth, 212 Adriance Lab Rd,1266 TAMU, College Stn, TX 77843 USA
关键词
Colorants; Textiles; LC-MS; MS; HPLC-DAD; Standard method; Exact-matching double isotope dilution mass spectrometry; MILD EXTRACTION; DYES; IDENTIFICATION;
D O I
10.1007/s00769-020-01438-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The DIN 54231:2005 and ISO 16373-2:2014 standard methods recommend the application of HPLC separations and detection by either diode array (HPLC-DAD) or mass spectrometric detectors (LC-MS or LC-MS/MS) for the evaluation of mass concentration of colorants (y >= 1.0 mu g/mL) in textile sample extracts. The present investigation reports for the first time that the LC-MS/MS method has low accuracy for most of textile colorants if the recommended calibration range of the standard methods (1.0 mu g/mL to 20 mu g/mL or 5.0 mu g/mL to 50 mu g/mL) is used. The present paper reports that the quantification of mass concentration of colorants in textile extract by the LC-MS/MS method does not match with the quantification by the HPLC-DAD method, which has fit-for-purpose linearity and accuracy in the ranges mentioned above. A systematic study of the MS/MS method was performed to prepare real and spiked samples for quantifying mass concentration of colorants (y <= 1.0 mu g/mL) in textile extracts for compounds having LOQ <= 1.0 mg/kg. The results obtained could match with the quantification by the HPLC-DAD method. A lower calibration range was needed to quantify the dyes in the diluted sample extracts in which the background matrix constituents had lower influence on the quantification. Significantly, the LC-MS/MS method utilizing sample dilution and lower calibration range was validated and then used to proficiency test (PT) samples with success. Furthermore, the evaluation of mass fraction of disperse yellow 3 in PT sample by exact-matching double isotope dilution mass spectrometry was also performed. The strategy presented herein to quantify a wide range of colorants using the LC-MS/MS method could improve the reproducibility of analyzing colorants using protocols of standard recommendations.
引用
收藏
页码:259 / 272
页数:14
相关论文
共 50 条
  • [21] Quantification of imatinib in human plasma by high-performance liquid chromatography-tandem mass spectrometry
    Titier, Karine
    Picard, Stephane
    Ducint, Dominique
    Teilhet, Emmanuelle
    Moore, Nicholas
    Berthaud, Patrice
    Mahon, Francois-Xavier
    Molimard, Mathieu
    THERAPEUTIC DRUG MONITORING, 2005, 27 (05) : 634 - 640
  • [22] Analysis of procyanidins in chocolate by reversed-phase high-performance liquid chromatography with electrospray ionisation mass spectrometric and tandem mass spectrometric detection
    Wollgast, J
    Pallaroni, L
    Agazzi, ME
    Anklam, E
    JOURNAL OF CHROMATOGRAPHY A, 2001, 926 (01) : 211 - 220
  • [23] An improved high-performance liquid chromatography-tandem mass spectrometric method to measure atrazine and its metabolites in human urine
    Panuwet, Parinya
    Restrepo, Paula A.
    Magsumbol, Melina
    Jung, Kyung Y.
    Montesano, M. Angela
    Needham, Larry L.
    Barr, Dana Boyd
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (13-14): : 957 - 962
  • [24] Speciation analysis of selenium in garlic by two-dimensional high-performance liquid chromatography with parallel inductively coupled plasma mass spectrometric and electrospray tandem mass spectrometric detection
    McSheehy, S
    Yang, WJ
    Pannier, F
    Szpunar, J
    Lobinski, R
    Auger, J
    Potin-Gautier, M
    ANALYTICA CHIMICA ACTA, 2000, 421 (02) : 147 - 153
  • [25] Determination of plant and enterolignans in human serum by high-performance liquid chromatography with tandem mass spectrometric detection
    Smeds, Annika I.
    Hakala, Kristo
    Hurmerinta, Teija T.
    Kortela, Liisi
    Saarinen, Niina M.
    Makela, Sari I.
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 41 (03) : 898 - 905
  • [26] Peculiarities of the Mass Spectrometric Detection of Anthocyanins in High-Performance Liquid Chromatography
    V. I. Deineka
    A. N. Sidorov
    A. N. Chulkov
    L. A. Deineka
    Journal of Analytical Chemistry, 2017, 72 : 1441 - 1445
  • [27] Peculiarities of the Mass Spectrometric Detection of Anthocyanins in High-Performance Liquid Chromatography
    Deineka, V. I.
    Sidorov, A. N.
    Chulkov, A. N.
    Deineka, L. A.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 72 (14) : 1441 - 1445
  • [28] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC MASS-SPECTROMETRIC AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC TANDEM MASS-SPECTROMETRIC ANALYSIS OF CARBAMATE PESTICIDES
    CHIU, KS
    VANLANGENHOVE, A
    TANAKA, C
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1989, 18 (03): : 200 - 206
  • [29] Identification and mass spectrometric characterization of glycosylated flavonoids in Triticum durum plants by high-performance liquid chromatography with tandem mass spectrometry
    Cavaliere, C
    Foglia, P
    Pastorini, E
    Samperi, R
    Laganà, A
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2005, 19 (21) : 3143 - 3158
  • [30] Determination of cotinine in urine and wastewaters by high performance liquid chromatography coupled with tandem mass-spectrometric detection
    Jang M.
    Pirogov A.V.
    Maksimova A.A.
    Dobrovolskiy V.I.
    Stakheev A.A.
    Abramova J.V.
    Priadka A.A.
    Jaricov A.P.
    Nosyrev A.E.
    Rozhanets V.V.
    Shpigun O.A.
    Moscow University Chemistry Bulletin, 2018, 73 (6) : 272 - 279