Efficacy and safety of a 7.5% icodextrin peritoneal dialysis solution in patients treated with automated peritoneal dialysis

被引:107
|
作者
Plum, J
Gentile, S
Verger, C
Brunkhorst, R
Bahner, U
Faller, B
Peeters, J
Freida, P
Struijk, DG
Krediet, RT
Grabensee, B
Tranaeus, A
Filho, JCD
机构
[1] Univ Dusseldorf, Dept Nephrol & Rheumatol, D-40225 Dusseldorf, Germany
[2] Hosp Rene Dubos, Unite Dialyse Cevitoneale, Pontoise, France
[3] Klinikum Hannover, Dept Nephrol, Hannover, Germany
[4] Med Univ, Dept Nephrol, Wurzburg, Germany
[5] Hosp Louis Pasteur, Serv Nephrol & Dialyse, Colmar, France
[6] AZ KUL Gasthuisberg, Dept Nephrol, Louvain, Belgium
[7] Hosp Louis Pasteur, Serv Nephrol & Dialyse, Cherbourg, France
[8] Acad Med Ctr, Dept Nephrol, Amsterdam, Netherlands
[9] Baxter SA, Div Renal, Brussels, Belgium
关键词
icodextrin; automated peritoneal dialysis; ultrafiltration; sodium; metabolic effects;
D O I
10.1053/ajkd.2002.32009
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
In a randomized, prospective, multicenter study, we compared the safety, efficacy, and metabolic effects of a 7.5% icodextrin solution (Extraneal) with a 2.27% glucose solution for long dwell exchanges in patients undergoing automated peritoneal dialysis. Thirty-nine stable patients on automated peritoneal dialysis were randomized to receive either icodextrin (n = 20) or glucose 2.27% solution (n = 19). The study included a 2-week baseline period followed by a 12-week icodextrin treatment phase and a 2-week follow-up period when switching back to glucose. The average net ultrafiltration during the long dwell period was 278 +/- 43 mL/d for the Icodextrin group and -138 +/- 81 mL/d for the control group (P < 0.001). The higher ultrafiltration volume with Icodextrin was associated with higher creatinine (2.59 +/- 0.09 mL/min versus 2.16 +/- 0.11 mL/min) and urea (2.67 +/- 0.09 mL/min versus 2.28 +/- 0.12 mL/min) peritoneal clearances for the long dwell (both P < 0.001). Ultrafiltration rate per mass of carbohydrate absorbed was +5.2 +/- 1.2 muL/min/g in the icodextrin group and -5.5 +/- 2.8 muL/min/g In the glucose group (P < 0.001). In the icodextrin group, there was a decrease in serum sodium and chloride compared with baseline (P < 0.01). Total dialysate sodium removal increased in the icodextrin group from 226.7 mEq to 269.6 mEq (week 12, P < 0.001). Serum a-amylase activity decreased from 103 U/L to 16 U/L (P < 0.001). The total icodextrin plasma levels reached a steady-state concentration of 6,187 +/- 399 mg/L after 1 week of treatment. Urine volume and residual renal function were not specifically affected by icodextrin compared with glucose. None of the laboratory changes resulted in any reported clinically meaningful side effect. Icodextrin produced increased, sustained ultrafiltration during the long dwell period, increasing (convective) peritoneal clearance and sodium removal In automated peritoneal dialysis patients. (C) 2002 by the National Kidney Foundation, Inc.
引用
收藏
页码:862 / 871
页数:10
相关论文
共 50 条
  • [31] ''Icodextrin alone" for initiation of peritoneal dialysis
    Jeloka, T. K.
    [J]. PERITONEAL DIALYSIS INTERNATIONAL, 2008, 28 (05): : 563 - 564
  • [32] The impact of icodextrin on the outcomes of incident peritoneal dialysis patients
    Wang, I-Kuan
    Chan, Chan Ip
    Lin, Alfred Hsing-Fen
    Yu, Tung-Min
    Yen, Tzung-Hai
    Lai, Ping-Chin
    Li, Chi-Yuan
    Sung, Fung-Chang
    [J]. PLOS ONE, 2024, 19 (03):
  • [33] Skin reactions with the use of icodextrin in peritoneal dialysis patients
    Vizcaino Castillo, Belen
    Beltran Catalan, Sandra
    Molina Vila, Pablo
    Gonzalez Moya, Mercedes
    Noguera-Morel, Lucero
    Pallardo Mateu, Luis Manuel
    [J]. NEFROLOGIA, 2019, 39 (02): : 211 - 213
  • [34] The impact of icodextrin on quality of life in peritoneal dialysis patients
    Cearing, Deborah
    McGreevey, Rona
    [J]. NEPHROLOGY NURSING JOURNAL, 2006, 33 (02) : 136 - 136
  • [35] Clinical effects of icodextrin in peritoneal dialysis
    Cnossen, Trijntje T.
    Konings, Constantijn J.
    van der Sande, Frank M.
    Leunissen, Karel M.
    Kooman, Jeroen P.
    [J]. CLINICAL KIDNEY JOURNAL, 2008, 1 : IV18 - IV22
  • [36] Modification of peritoneal dialysis: Intermittent automated peritoneal dialysis
    Okada, K
    Takahashi, S
    [J]. NEPHRON, 1997, 77 (01): : 109 - 110
  • [37] EFFECT OF ICODEXTRIN SOLUTION ON PRESERVATION OF RESIDUAL RENAL FUNCTION IN PERITONEAL DIALYSIS PATIENTS
    Han, Seung Hyeok
    Chang, Tae Ik
    Ryu, Dong-Ryeol
    Yoo, Tae-Hyun
    Kim, Hyung Jong
    Kang, Ea Wha
    Kim, Hyunwook
    Chang, Jae Hyun
    Kim, Dong Ki
    Moon, Sung Jin
    Yoon, Soo Young
    [J]. NEPHROLOGY DIALYSIS TRANSPLANTATION, 2015, 30
  • [39] Effect of icodextrin peritoneal dialysis solution on cell proliferation in vitro
    Cooker, LA
    Choo, CG
    Luneburg, P
    Lamela, J
    Holmes, CJ
    [J]. ADVANCES IN PERITONEAL DIALYSIS/1999, VOL 15, 1999, 15 : 17 - 20
  • [40] Automated peritoneal dialysis in urgent-start dialysis ESRD patients: Safety and dialysis adequacy
    Jin, Haijiao
    Lv, Shifan
    Wang, Ling
    Zhang, Minfang
    Wang, Qin
    Fang, Wei
    Lin, Xinghui
    Che, Xiajing
    Yan, Hao
    Yu, Zanzhe
    Jiang, Na
    Li, Zhenyuan
    Che, Miaoling
    Ding, Li
    Huang, Jiaying
    Zhou, Yin
    Ni, Zhaohui
    [J]. THERAPEUTIC APHERESIS AND DIALYSIS, 2023, 27 (03) : 464 - 470