Automated peritoneal dialysis in urgent-start dialysis ESRD patients: Safety and dialysis adequacy

被引:3
|
作者
Jin, Haijiao [1 ,2 ]
Lv, Shifan [1 ,2 ]
Wang, Ling [1 ,2 ]
Zhang, Minfang [1 ,2 ]
Wang, Qin [1 ,2 ]
Fang, Wei [1 ,2 ]
Lin, Xinghui [1 ,2 ]
Che, Xiajing [1 ,2 ]
Yan, Hao [1 ,2 ]
Yu, Zanzhe [1 ,2 ]
Jiang, Na [1 ,2 ]
Li, Zhenyuan [1 ,2 ]
Che, Miaoling [1 ,2 ]
Ding, Li [1 ,2 ]
Huang, Jiaying [1 ,2 ]
Zhou, Yin [1 ,2 ]
Ni, Zhaohui [1 ,2 ]
机构
[1] Shanghai Jiao Tong Univ, Renji Hosp, Dept Nephrol, Sch Med, Shanghai 200127, Peoples R China
[2] Shanghai Jiao Tong Univ, Clin Res Ctr, Sch Med, Shanghai, Peoples R China
关键词
automated peritoneal dialysis; dialysis adequacy; end-stage renal disease; urgent-start peritoneal dialysis; STAGE RENAL-DISEASE; BREAK-IN PERIOD; CONTROLLED-TRIAL; OUTCOMES; FEASIBILITY;
D O I
10.1111/1744-9987.13943
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Recent evidence suggests that automated peritoneal dialysis (APD) might be a feasible alternative to hemodialysis (HD) in urgent-start peritoneal dialysis. Methods This prospective study enrolled end-stage renal disease (ESRD) patients who had started APD as an urgent-start dialysis modality at a single center. Dialysis-related complications were recorded. Dialysis adequacy and electrolytes imbalance were compared between baseline, 14 and 42 days after catheter insertion. Technique survival and patient survival were also recorded. Results A total of 36 patients were included in the study. Mean follow-up duration was 22 months. During the follow-up, 11 PD patients (30.6%) developed dialysis-related complications. Only two patients (5.6%) required re-insertion and one patients (2.8%) transfer to HD. The 2-year technique survival rate and patient survival rate were 94.4% and 97.2%, respectively. Conclusion In considering safety and dialysis adequacy, APD could be a feasible dialysis modality for urgent-start dialysis in ESRD patients, using a standard procedure.
引用
收藏
页码:464 / 470
页数:7
相关论文
共 50 条
  • [1] A Randomized Controlled Trial Comparing Automated Peritoneal Dialysis and Hemodialysis for Urgent-Start Dialysis in ESRD
    Jin, Haijiao
    Fang, Wei
    Wang, Ling
    Zang, Xiujuan
    Deng, Yueyi
    Wu, Guoqing
    Li, Ying
    Chen, Xiaonong
    Wang, Niansong
    Jiang, Gengru
    Guo, Zhiyong
    Wang, Xiaoxia
    Qi, Yinghui
    Lv, Shifan
    Ni, Zhaohui
    [J]. KIDNEY INTERNATIONAL REPORTS, 2024, 9 (09): : 2627 - 2634
  • [2] Urgent-start peritoneal dialysis
    Yaxley, Julian
    Scott, Tahira
    [J]. NEFROLOGIA, 2023, 43 (03): : 293 - 301
  • [3] Urgent-start peritoneal dialysis
    Pellizzari, Caio
    de Moraes, Thyago Proenca
    [J]. JORNAL BRASILEIRO DE NEFROLOGIA, 2022, 44 (04): : 464 - 465
  • [4] URGENT-START OF PERITONEAL DIALYSIS
    Elena Biain, Maria
    Laham, Gustavo
    Pattin, Mauricio
    Rodriguez, Susana
    Pochiero, Lujan
    Diaz, Carlos
    [J]. REVISTA DE NEFROLOGIA DIALISIS Y TRASPLANTE, 2015, 35 (02): : 75 - 79
  • [5] Urgent-Start Peritoneal Dialysis and Hemodialysis in ESRD Patients: Complications and Outcomes
    Jin, Haijiao
    Fang, Wei
    Zhu, Mingli
    Yu, Zanzhe
    Fang, Yan
    Yan, Hao
    Zhang, Minfang
    Wang, Qin
    Che, Xiajing
    Xie, Yuanyuan
    Huang, Jiaying
    Hu, Chunhua
    Zhang, Haifen
    Mou, Shan
    Ni, Zhaohui
    [J]. PLOS ONE, 2016, 11 (11):
  • [6] Automated peritoneal dialysis as a cost-effective urgent-start dialysis option for ESRD patients: A prospective cohort study
    Jin, Haijiao
    Lu, Renhua
    Lv, Shifan
    Wang, Ling
    Mou, Shan
    Zhang, Minfang
    Wang, Qin
    Pang, Huihua
    Yan, Hao
    Li, Zhenyuan
    Che, Miaoling
    Shen, Jianxiao
    Yan, Jiayi
    Gu, Aiping
    Zhang, Haifen
    Liu, Qian
    Fang, Nina
    Jin, Yan
    Ni, Zhaohui
    [J]. INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2022, 45 (08): : 672 - 679
  • [7] Application of automated peritoneal dialysis in urgent-start peritoneal dialysis patients during the break-in period
    Liu, Shengmao
    Zhuang, Xiaohua
    Zhang, Min
    Wu, Yanfeng
    Liu, Min
    Guan, Sibo
    Liu, Shujun
    Miao, Lining
    Cui, Wenpeng
    [J]. INTERNATIONAL UROLOGY AND NEPHROLOGY, 2018, 50 (03) : 541 - 549
  • [8] Application of automated peritoneal dialysis in urgent-start peritoneal dialysis patients during the break-in period
    Shengmao Liu
    Xiaohua Zhuang
    Min Zhang
    Yanfeng Wu
    Min Liu
    Sibo Guan
    Shujun Liu
    Lining Miao
    Wenpeng Cui
    [J]. International Urology and Nephrology, 2018, 50 : 541 - 549
  • [9] Truly Urgent "Urgent-Start" Peritoneal Dialysis
    Chiu, Michael
    Jain, Arsh K.
    Blake, Peter G.
    [J]. KIDNEY INTERNATIONAL REPORTS, 2020, 5 (10): : 1625 - 1626
  • [10] Factors Associated With Urgent-Start Peritoneal Dialysis Catheter Complications in ESRD
    Hernandez-Castillo, Jose L.
    Balderas-Juarez, Joana
    Jimenez-Zarazua, Omar
    Guerrero-Toriz, Karen
    Loeza-Uribe, Michelle P.
    Tenorio-Aguirre, Erika K.
    Mendoza-Garcia, Jesus G.
    Mondragon, Jaime D.
    [J]. KIDNEY INTERNATIONAL REPORTS, 2020, 5 (10): : 1722 - 1728