A Novel Cell-Based Hybrid Acoustic Wave Biosensor with Impedimetric Sensing Capabilities

被引:24
|
作者
Liu, Fei [1 ]
Li, Fang [2 ]
Nordin, Anis Nurashikin [3 ]
Voiculescu, Ioana [1 ]
机构
[1] CUNY City Coll, Dept Mech Engn, New York, NY 10031 USA
[2] New York Inst Technol, Dept Mech Engn, Old Westbury, NY 11568 USA
[3] Int Islamic Univ Malaysia, Kuala Lumpur 53100, Malaysia
来源
SENSORS | 2013年 / 13卷 / 03期
关键词
quartz crystal microbalance; thickness shear mode; impedance spectroscopy measurements; resonant frequency; bovine aortic endothelial cells; COMSOL Multiphysics (TM); QUARTZ-CRYSTAL MICROBALANCE; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; REAL-TIME; VISCOELASTIC PROPERTIES; TISSUE-CULTURE; SENSORS; TOXICITY; MICROMOTION; PATHOGENS; ADHESION;
D O I
10.3390/s130303039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel multiparametric biosensor system based on living cells will be presented. The biosensor system includes two biosensing techniques on a single device: resonant frequency measurements and electric cell-substrate impedance sensing (ECIS). The multiparametric sensor system is based on the innovative use of the upper electrode of a quartz crystal microbalance (QCM) resonator as working electrode for the ECIS technique. The QCM acoustic wave sensor consists of a thin AT-cut quartz substrate with two gold electrodes on opposite sides. For integration of the QCM with the ECIS technique a semicircular counter electrode was fabricated near the upper electrode on the same side of the quartz crystal. Bovine aortic endothelial live cells (BAECs) were successfully cultured on this hybrid biosensor. Finite element modeling of the bulk acoustic wave resonator using COMSOL simulations was performed. Simultaneous gravimetric and impedimetric measurements performed over a period of time on the same cell culture were conducted to validate the device's sensitivity. The time necessary for the BAEC cells to attach and form a compact monolayer on the biosensor was 35 similar to 45 minutes for 1.5 x 10(4) cells/cm(2) BAECs; 60 minutes for 2.0 x 10(4) cells/cm(2) BAECs; 70 minutes for 3.0 x 10(4) cells/cm(2) BAECs; and 100 minutes for 5.0 x 10(4) cells/cm(2) BAECs. It was demonstrated that this time is the same for both gravimetric and impedimetric measurements. This hybrid biosensor will be employed in the future for water toxicity detection.
引用
收藏
页码:3039 / 3055
页数:17
相关论文
共 50 条
  • [31] Integrated cell-based biosensor for extracellular electrophysiological monitoring
    Ying, Xu
    Hui, Yu
    Hua, Cai
    Liu Qingjun
    Wang, Ping
    2007 INTERNATIONAL CONFERENCE ON INFORMATION ACQUISITION, VOLS 1 AND 2, 2007, : 69 - 74
  • [32] Portable cell-based biosensor system for toxin detection
    Pancrazio, JJ
    Bey, PP
    Cuttino, DS
    Kusel, JK
    Borkholder, DA
    Shaffer, KM
    Kovacs, GTA
    Stenger, DA
    SENSORS AND ACTUATORS B-CHEMICAL, 1998, 53 (03) : 179 - 185
  • [33] Application of cellular micropatterns to miniaturized cell-based biosensor
    Lee H.J.
    Han S.W.
    Chung U.S.
    Koh W.-G.
    Biomedical Engineering Letters, 2013, 3 (03) : 117 - 130
  • [34] Cell-based biosensor for measurement of phenol and nitrophenols toxicity
    Liu, Chang
    Yong, Daming
    Yu, Dengbin
    Dong, Shaojun
    TALANTA, 2011, 84 (03) : 766 - 770
  • [35] Enzyme biosensor based on surface acoustic wave device
    Kondoh, J
    Imayama, T
    Matsui, Y
    Shiokawa, S
    ELECTRONICS AND COMMUNICATIONS IN JAPAN PART II-ELECTRONICS, 1996, 79 (07): : 69 - 75
  • [36] A novel cell-based AAV RNA-sensing infectivity reporter assay
    Vitu, E.
    HUMAN GENE THERAPY, 2024, 35 (3-4) : A105 - A105
  • [37] A novel leaky surface acoustic wave biosensor for detection of PKA activity in cell lysates based on peptide biomineralized metal nanoclusters
    Rauf, Sana
    Luo, Jingting
    Qazi, Hafiz Imran Ahmad
    Sohail, Muhammad
    Tao, Ran
    Fu, Chen
    Rauf, Sajid
    Ahmad, Ishtiaq
    Iqbal, Hafiz M. N.
    Li, Honglang
    SENSORS AND ACTUATORS A-PHYSICAL, 2023, 351
  • [38] Impedimetric biosensor based on cell-mediated bioimprinted films for bacterial detection
    Qi, Peng
    Wan, Yi
    Zhang, Dun
    BIOSENSORS & BIOELECTRONICS, 2013, 39 (01): : 282 - 288
  • [39] A novel electrochemical mast cell-based paper biosensor for the rapid detection of milk allergen casein
    Jiang, Donglei
    Ge, Panwei
    Wang, Lifeng
    Jiang, Hui
    Yang, Ming
    Yuan, Limin
    Ge, Qingfeng
    Fang, Weiming
    Ju, Xingrong
    BIOSENSORS & BIOELECTRONICS, 2019, 130 : 299 - 306
  • [40] A novel and simple cell-based electrochemical impedance biosensor for evaluating the combined toxicity of DON and ZEN
    Gu, Wenshu
    Zhu, Pei
    Jiang, Donglei
    He, Xingxing
    Li, Yun
    Ji, Jian
    Zhang, Lijuan
    Sun, Yange
    Sun, Xiulan
    BIOSENSORS & BIOELECTRONICS, 2015, 70 : 447 - 454