A Novel Cell-Based Hybrid Acoustic Wave Biosensor with Impedimetric Sensing Capabilities

被引:24
|
作者
Liu, Fei [1 ]
Li, Fang [2 ]
Nordin, Anis Nurashikin [3 ]
Voiculescu, Ioana [1 ]
机构
[1] CUNY City Coll, Dept Mech Engn, New York, NY 10031 USA
[2] New York Inst Technol, Dept Mech Engn, Old Westbury, NY 11568 USA
[3] Int Islamic Univ Malaysia, Kuala Lumpur 53100, Malaysia
来源
SENSORS | 2013年 / 13卷 / 03期
关键词
quartz crystal microbalance; thickness shear mode; impedance spectroscopy measurements; resonant frequency; bovine aortic endothelial cells; COMSOL Multiphysics (TM); QUARTZ-CRYSTAL MICROBALANCE; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; REAL-TIME; VISCOELASTIC PROPERTIES; TISSUE-CULTURE; SENSORS; TOXICITY; MICROMOTION; PATHOGENS; ADHESION;
D O I
10.3390/s130303039
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel multiparametric biosensor system based on living cells will be presented. The biosensor system includes two biosensing techniques on a single device: resonant frequency measurements and electric cell-substrate impedance sensing (ECIS). The multiparametric sensor system is based on the innovative use of the upper electrode of a quartz crystal microbalance (QCM) resonator as working electrode for the ECIS technique. The QCM acoustic wave sensor consists of a thin AT-cut quartz substrate with two gold electrodes on opposite sides. For integration of the QCM with the ECIS technique a semicircular counter electrode was fabricated near the upper electrode on the same side of the quartz crystal. Bovine aortic endothelial live cells (BAECs) were successfully cultured on this hybrid biosensor. Finite element modeling of the bulk acoustic wave resonator using COMSOL simulations was performed. Simultaneous gravimetric and impedimetric measurements performed over a period of time on the same cell culture were conducted to validate the device's sensitivity. The time necessary for the BAEC cells to attach and form a compact monolayer on the biosensor was 35 similar to 45 minutes for 1.5 x 10(4) cells/cm(2) BAECs; 60 minutes for 2.0 x 10(4) cells/cm(2) BAECs; 70 minutes for 3.0 x 10(4) cells/cm(2) BAECs; and 100 minutes for 5.0 x 10(4) cells/cm(2) BAECs. It was demonstrated that this time is the same for both gravimetric and impedimetric measurements. This hybrid biosensor will be employed in the future for water toxicity detection.
引用
收藏
页码:3039 / 3055
页数:17
相关论文
共 50 条
  • [21] A novel label-free bioengineered cell-based biosensor for salicin detection
    Hu, Liang
    Zou, Lin
    Qin, Zhen
    Fang, Jiaru
    Huang, Liquan
    Wang, Ping
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 238 : 1151 - 1158
  • [22] A packed microcolumn approach to a cell-based biosensor
    Flemming, JH
    Baca, HK
    Werner-Washburne, M
    Brozik, SM
    López, GP
    SENSORS AND ACTUATORS B-CHEMICAL, 2006, 113 (01): : 376 - 381
  • [23] Sensitive cell-based fish chromatophore biosensor
    Plant, TK
    Chaplen, FW
    Jovanovic, G
    Kolodziej, W
    Trempy, JE
    Willard, C
    Liburdy, JA
    Pence, DV
    Paul, BK
    BIOMEDICAL VIBRATIONAL SPECTROSCOPY AND BIOHAZARD DETECTION TECHNOLOGIES, 2004, 5321 : 265 - 274
  • [24] Design and demonstration of an automated cell-based biosensor
    Gray, SA
    Kusel, JK
    Shaffer, KM
    Shubin, YS
    Stenger, DA
    Pancrazio, JJ
    BIOSENSORS & BIOELECTRONICS, 2001, 16 (7-8): : 535 - 542
  • [25] A cell-based electrochemical biosensor for the detection of capsaicin
    Gao, Liying
    Li, Zhihua
    Wei, Xiaoou
    Hao, Mengyu
    Song, Wenjun
    Zou, Xiaobo
    Huang, Xiaowei
    JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION, 2024, 18 (11) : 9341 - 9352
  • [26] A lab-on-chip cell-based biosensor for label-free sensing of water toxicants
    Liu, F.
    Nordin, A. N.
    Li, F.
    Voiculescu, I.
    LAB ON A CHIP, 2014, 14 (07) : 1270 - 1280
  • [27] Zirconium dioxide nanolayer passivated impedimetric sensors for cell-based assays
    Sticker, Drago
    Rothbauer, Mario
    Charwat, Verena
    Steinkuehler, Jan
    Bethge, Ole
    Bertagnolli, Emmerich
    Wanzenboeck, Heinz D.
    Ertl, Peter
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 213 : 35 - 44
  • [28] The optimization of automatic fluidic system for cell-based biosensor
    Xu, Gaixia
    Wang, Ping
    Xu, Ying
    Liu, Qingjun
    Qin, Lifeng
    Ding, Zhihua
    Niu, Hanben
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1948 - 1951
  • [29] A cell-based biosensor for pathological tau uptake and aggregation
    Hapuarachchi, B.
    Roberts, M.
    Staddon, J.
    Warner, T.
    de Silva, R.
    NEUROPATHOLOGY AND APPLIED NEUROBIOLOGY, 2015, 41 : 9 - 10
  • [30] Cell-based biosensor for rapid screening of pathogens and toxins
    Banerjee, Pratik
    Bhunia, Arun K.
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (01): : 99 - 106