摘要
The 4 MV photon beam offers equal build-up region behavior like Co-60 beam and it plays a major role in head and neck and pediatric radiotherapy. In this study an attempt is made to study the head scatter factor (S-c) for 4 MV photon beam using locally designed PMMA and Brass miniphantoms. The S-c is measured in combination of PMMA miniphantom with 0.6 cc chamber and Brass miniphantom with 0.6 cc and 0.13 cc chambers. The measured S-c is compared with the literature data and it agrees within +/- 1.98%. The study reveals that either 0.13 cc or 0.6 cc chamber with PMMA or Brass phantom materials can be used for S-c measurements in a 4 MV photon beam. The variation of SSD does not alter the head scatter factor: The collimator exchange effect is found to be within 1, and it is less than that of other linear accelerators. It is also found that the presence of internal wedge has significant contribution to head scatter factor. The Phantom scatter factor is also calculated and it agrees within +/- 1% with published data.
引用
收藏
页码:207 / 216
页数:10
相关论文
共 50 条
  • [1] Dosimetric evaluation of the Acuros XB algorithm for a 4MV photon beam in head and neck intensity-modulated radiation therapy
    Hirata, Kimiko
    Nakamura, Mitsuhiro
    Yoshimura, Michio
    Mukumoto, Nobutaka
    Nakata, Manabu
    Ito, Hitoshi
    Inokuchi, Haruo
    Matsuo, Yukinori
    Mizowaki, Takashi
    Hiraoka, Masahiro
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2015, 16 (04): : 52 - 64
  • [2] Source model tuning for a 6 MV photon beam used in radiotherapy
    Hirschi, Lukas A.
    Siebers, Jeffrey V.
    Fix, Michael K.
    FIRST EUROPEAN WORKSHOP ON MONTE CARLO TREATMENT PLANNING, 2007, 74
  • [3] COMPUTER GENERATED SCATTER DOSE DISTRIBUTIONS FOR A 6 MV RADIOTHERAPY PHOTON-BEAM
    BLOCH, P
    WALLACE, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 761 - 761
  • [4] COMPUTER GENERATED SCATTER DOSE DISTRIBUTIONS FOR A 6MV RADIOTHERAPY PHOTON BEAM
    BLOCH, P
    WALLACE, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1979, 5 : 74 - 74
  • [5] Measurement and comparison of head scatter factor for 7 MV unflattened (FFF) and 6 MV flattened photon beam using indigenously designed columnar mini phantom
    Ashokkumar, Sigamani
    Nambiraj, Arunai
    Sinha, Sujit Nath
    Yadav, Girigesh
    Raman, Kothanda
    Bhushan, Manindra
    Thiyagarajan, Rajesh
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (03) : 170 - 180
  • [6] DESIGN AND BEAM PROPERTIES OF A 4MV TOTAL-BODY IRRADIATOR
    LUTZ, WR
    SVENSSON, GK
    BJARNGARD, BE
    MEDICAL PHYSICS, 1983, 10 (04) : 539 - 539
  • [7] Comparison of Head Scatter Factor for 6MV and 10MV flattened (FB) and Unflattened (FFF) Photon Beam using indigenously Designed Columnar Mini Phantom
    Ashokkumar, Sigamani
    Raj, Arunai Nambi N.
    Sinha, Sujit Nath
    Yadav, Girigesh
    Thiyagarajan, Rajesh
    Raman, Kothanda
    Mishra, Manindra Bhushan
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (03) : 184 - 191
  • [8] Dosimetric Validation of the Algorithm Based On Linear Boltzmann Transport Equations for Photon 4MV Dose Calculation
    Sato, S.
    Miyabe, Y.
    Nakata, M.
    Tsuruta, Y.
    Nakamura, M.
    Mizowaki, T.
    Hiraoka, M.
    MEDICAL PHYSICS, 2012, 39 (06) : 3826 - 3826
  • [9] A widely tested model for head scatter influence on photon beam output
    Olofsson, J
    Georg, D
    Karlsson, M
    RADIOTHERAPY AND ONCOLOGY, 2003, 67 (02) : 225 - 238
  • [10] Impact of Acuros XB on dose distribution for 4-MV photon beam in head and neck IMRT
    Hirata, K.
    Nakamura, M.
    Yoshimura, M.
    Mukumoto, N.
    Ito, H.
    Inokuchi, H.
    Matsuo, Y.
    Mizowaki, T.
    Hiraoka, M.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S67 - S68